Journal of Physics and Its Applications
Vol 8, No 3 (2026): August 2026

Optimizing Dose Distribution with Direct Aperture Optimization: A MatRad-Based Analysis

Fajar Miraz Fauzi (Nuclear Physics and Biophysics Research Group, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung, Bandung, Indonesia)
Siti Mutmainnah (Nuclear Physics and Biophysics Research Group, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung, Bandung, Indonesia)
Rio Rizky Rahmadani (Nuclear Physics and Biophysics Research Group, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung, Bandung, Indonesia)
Freddy Haryanto (Nuclear Physics and Biophysics Research Group, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung, Bandung, Indonesia)



Article Info

Publish Date
31 Aug 2026

Abstract

Advanced optimization algorithms like Direct Aperture Optimization (DAO) are integral to modern radiotherapy, yet research is often hindered by the limited accessibility of commercial Treatment Planning Systems. Open-source platforms like matRad provide a vital framework for such investigations. This study evaluates the dosimetric impact of DAO activation and its interplay with varying bixel resolutions (5×5 to 10×10 mm²) using matRad for a liver cancer case. Twelve treatment plans were generated and calculated using the ompMC Monte Carlo engine. Initial verification yielded a 3.14% mean relative statistical uncertainty, indicating that the stochastic uncertainty was relatively small compared with the dosimetric differences investigated. Twelve plans were assessed using Dose Volume Histograms (DVHs), Conformity Index (CI), and Homogeneity Index (HI). Results showed DAO significantly reduced stomach dose (e.g., 6.33% at 5×5 mm²; p=0.031). At 5×5 mm², heart and liver mean doses decreased by 7.15% and 1.83% respectively, though these changes were resolution-dependent and statistically non-significant. For targets, DAO at 5×5 mm² caused minor, non-significant mean dose increases for the GTV (1.3%), CTV (1.01%), and PTV (0.77%). Conversely, while maintaining target coverage, DAO activation produced a statistically significant degradation in dose conformity and homogeneity across all bixel sizes (p=0.031). These findings highlight an inherent optimization trade-off that DAO prioritizes steep dose gradients for maximal OAR protection at the expense of minor internal target dose heterogeneity. This study establishes matRad as an effective environment for elucidating optimization behaviors in radiotherapy planning.

Copyrights © 2026






Journal Info

Abbrev

jpa

Publisher

Subject

Astronomy Earth & Planetary Sciences Materials Science & Nanotechnology Physics

Description

Journal of Physics and Its Applications (JPA) (e-ISSN: 2622-5956) is open access, International peer-reviewed journal that publishes high-novelty and original research papers and review papers in the field of physics including Radiation Physics, Materials, Geophysics, Theoretical Physics, ...