The use of phase change materials (PCMs) for latent heat storage holds potential for application in battery thermal management systems (BTMS). This study compares the thermal characteristics of PCM-1 (60% lauric acid–40% palmitic acid) and PCM-2 (60% myristic acid–40% lauric acid) using Differential Scanning Calorimetry (DSC) testing. The parameters analyzed include the phase change start temperature, onset temperature, peak temperature, endset temperature, test end temperature, and latent heat. Test results indicate that PCM-1 has an onset temperature of 36.68°C, a peak temperature of 39.21°C, an endset of 41.68°C, and a latent heat of 137.74 J/g. PCM-2 exhibits an onset temperature of 40.77°C, a peak temperature of 45.63°C, an endset of 53.36°C, and a latent heat of 15.01 J/g. Thus, PCM-1 possesses a significantly higher latent heat storage capacity than PCM-2, whereas PCM-2 undergoes phase change at a higher temperature and over a wider temperature range. Based on these characteristics, PCM-1 is more promising for BTMS applications requiring high latent heat absorption capabilities within the 35–42°C temperature range.