Jurnal Pendidikan Teknik Mesin
Vol. 26 No. 01 (2026): June 2026 "Special issues for finite element analysis"

FIRST MANDIBULAR MOLAR IMPLANT SYSTEM UNDER ORTHOTROPIC BONE VARIATIONS: A FINITE ELEMENT SENSITIVITY ANALYSI

Fatkhu Amanulloh (Universitas Negeri Semarang)
Kriswanto (Universitas Negeri Semarang)
Ruben Bayu Kristiawan (Universitas Negeri Semarang)
Jamari (Universitas Diponegoro)
Athanasius Priharyoto Bayuseno (Universitas Negeri Semarang)
Dhiaulhaque (Universitas Diponegoro)
Dzikra Adi Pratama (Universitas Negeri Semarang)
Mohd Syahmi Jamaludin (Department of Mechanical and Manufacturing, Faculty of Engineering, Universiti Malaysia Sarawak, Samarahan, Sarawak, Malaysia)



Article Info

Publish Date
10 Aug 2026

Abstract

Physiological variability in bone mechanical properties may affect load transfer and biomechanical stability in dental implant systems. However, the influence of orthotropic elastic and shear properties on implant–bone biomechanics remains unclear. This study evaluated the sensitivity and robustness of a mandibular first molar implant system to variations in orthotropic bone properties using finite element analysis. A three-dimensional implant–bone model was analyzed under nine material configurations, including gradual orthotropic variations (±15% of baseline) and independent modifications of the elastic and shear modulus. Biomechanical responses were evaluated using von Mises stress, principal stresses, strains, and displacements. Stress concentrations were primarily located at the implant–abutment connection and crestal cortical bone, indicating the main load-transfer pathways. Increasing directional stiffness reduced peri-implant strain and displacement but increased cortical stress, revealing a trade-off between deformation reduction and local stress concentration. Elastic modulus predominantly influenced global stress redistribution, whereas shear modulus had a greater effect on local deformation and peri-implant stability. Strain and displacement were more sensitive to material variations than stress-based parameters. These findings emphasize the importance of orthotropic material representation for realistic biomechanical assessment of dental implant systems under physiological variations in bone quality.

Copyrights © 2026






Journal Info

Abbrev

JPTM

Publisher

Subject

Mechanical Engineering

Description

First published in June 2001 and since then it is published biannually in June and December. Contains articles lifted from the results of research on field mechanical engineering and the idea of thinking (conceptual) for the development of education and teaching in the field of Mechanical ...