This study aims to analyze the effect of Shielded Metal Arc Welding (SMAW) current variations and the hardening process, using SAE 90 oil as the quenching medium, on the tensile strength of ST41 steel. Welding was performed using E6013 electrodes with current variations of 60 A, 70 A, 80 A, 90 A, and 100 A. Following the welding process, the specimens were hardened at 850 °C for 600 seconds and quenched in SAE 90 oil. Tensile testing was conducted in accordance with the ASTM E8 standard to determine the tensile strength of the welded joints. The results indicate that an increase in welding current tends to improve the material's tensile strength. The highest average tensile strength was obtained at a current of 100 A, reaching 366.88 MPa, while the lowest was recorded at 60 A, yielding 169.85 MPa. A One-Way ANOVA revealed that the variations in welding current did not significantly affect the tensile strength at a 95% confidence level. Nevertheless, increasing the welding current demonstrated a tendency to produce welded joints with superior mechanical performance. The findings of this study can serve as a reference for selecting optimal welding and heat treatment parameters to enhance the joint quality of ST41 low carbon steel.