Journal Interdisciplinary Health
Vol. 2 No. 3 (2026): Journal Interdisciplinary Health

Comparison of 3D T2-FLAIR and Double Inversion Recovery Image Quality in Multiple Sclerosis Lesions at 3T MRI

Muh. Saifur Rohmad (Department of Radiologic Imaging Technology, Politeknik Sandi Karsa, Makassar, South Sulawesi)
Olivia Ganna (Department of Radiologic Imaging Technology, Politeknik Sandi Karsa, Makassar, South Sulawesi)
Akhirida Putra (Department of Radiologic Imaging Technology, Politeknik Sandi Karsa, Makassar, South Sulawesi)
Wenda Anastasia (Department of Radiologic Imaging Technology, Politeknik Sandi Karsa, Makassar, South Sulawesi)



Article Info

Publish Date
05 Aug 2026

Abstract

Introduction: Multiple sclerosis (MS) lesions may involve cortical and white matter regions and can be challenging to characterize using conventional magnetic resonance imaging (MRI). Three-dimensional T2 Fluid-Attenuated Inversion Recovery (3D T2-FLAIR) and Double Inversion Recovery (3D DIR) provide different tissue suppression characteristics; however, their relative image quality in MS patients with epileptic manifestations requires further evaluation. To compare the image quality of 3D T2-FLAIR and 3D DIR sequences for detecting MS lesions on 3 Tesla brain MRI using Signal-to-Noise Ratio (SNR) and Contrast-to-Noise Ratio (CNR). Research Methodology: This quantitative comparative retrospective study included 10 non-contrast 3 Tesla brain MRI examinations of patients with MS and epileptic manifestations. SNR and CNR were measured using regions of interest placed in white matter, gray matter, and MS lesions. Differences between 3D T2-FLAIR and 3D DIR were analyzed using the Wilcoxon signed-rank test with α=0.05. Results: T2-FLAIR demonstrated significantly higher white matter SNR than DIR (111.47 vs. 16.08; p=0.002). No significant differences were observed for gray matter SNR (156.17 vs. 182.71; p=0.275) or lesion SNR (170.61 vs. 229.78; p=0.105). DIR produced significantly higher lesion-to-white matter CNR than T2-FLAIR (577.51 vs. 398.25; p=0.049), while gray matter-to-white matter and lesion-to-gray matter CNR differences were not significant. Conclusion: 3D T2-FLAIR provides superior white matter SNR, whereas 3D DIR improves lesion-to-white matter contrast. Their complementary characteristics support combined use for more comprehensive evaluation of MS lesions on 3 Tesla MRI.

Copyrights © 2026






Journal Info

Abbrev

jih

Publisher

Subject

Health Professions Medicine & Pharmacology Nursing Public Health Veterinary

Description

Journal Interdisciplinary Health is a scientific journal that focuses on cross-disciplinary studies in the field of health, which aims to integrate various scientific approaches in understanding, analyzing, and finding solutions to health problems at the individual, community, and global levels. The ...