Building envelope design is one of the effective parameters for reducing energy consumption and enhancing thermal comfort. This research explores the impact of building envelope performance on indoor thermal comfort and heating energy consumption in university classrooms located in cold regions of China. A numerical model was established using field measurement data and subsequently validated. Four building envelope optimization schemes were designed by altering wall thermal resistance, roof insulation thickness, and window solar transmittance. Results indicate that enhanced wall insulation yields the most significant benefits: winter indoor temperatures increase by up to 0.72°C, summer temperatures decrease by 1.33°C, and annual energy use intensity(EUI) drops by approximately 34%. While roof insulation and reduced window solar transmittance provide weaker improvements in comfort and EUI reduction, they still contribute to enhanced indoor environments. The optimized building envelope effectively reduced winter cold discomfort and summer heat gain, stabilizing indoor conditions. However, even under optimal envelope conditions, complete thermal neutrality could not be achieved during extreme cold spells, indicating the need for supplemental heating strategies. These findings provide quantitative guidance for designing climate-adaptive building envelopes in educational facilities located in cold regions.