Indonesia's location on three tectonic plates and its many active volcanoes make it highly prone to earthquakes. To mitigate structural damage, engineers use earthquake-resistant elements like shear walls and base isolation. Shear walls are reinforced concrete plates that increase a building's stiffness and limit sideways movement. In contrast, base isolation systems, made of rubber and steel, are installed at the foundation to absorb seismic energy and reduce the ground's shaking effect on the building. A study analyzed the performance of 4, 6, and 8-story buildings in South Jakarta using both systems. The analysis, based on Indonesian building codes, used Robot Structural Analysis Professional (RSAP) 2025 to assess parameters like base shear, inter-story drift, and displacement. The results showed that base isolation significantly reduced base shear in taller buildings (39.5% for 8 stories, 21.45% for 6 stories), but less so in the 4-story building (13.90%). Base isolation also reduced inter-story drift by 64% in the 8-story building and about 9% in the 6-story building, but it surprisingly increased drift by 50% in the 4-story building compared to the shear wall system. This suggests that base isolation is more effective for high-rise buildings, while shear walls are better for providing stiffness. Ultimately, the best system depends on the building's height and specific seismic resistance goals.