Hydrocortisone injection is a sterile preparation that requires reconstitution in the perinatology ward so that it requires special handling using aseptic techniques and standard facilities. If not appropriate, hydrocortisone injection can be contaminated with bacteria. This study aims to determine the suitability of the compounding and sterility of hydrocortisone injection prepared in the clean room in the perinatology ward of a referral hospital. Data collection used an observational method on the compounding process of hydrocortisone injection in the perinatology ward. The sample consisted of 8 vials of hydrocortisone injection, determined using total sampling. The samples that had been taken were then tested for sterility. The results of the study showed that the compounding process of hydrocortisone injection did not meet the USP <797> standard. This is reinforced by the results of the test of the injection preparation experiencing microbial contamination. Contamination can occur because the compounding room in the perinatology ward is inadequate. Due to this contamination, it can be concluded that the reconstituted hydrocortisone preparation prepared in the perinatology ward does not meet the requirements of USP <797> and should therefore not be recommended for administration to patients for patient safety.