Journal of Electronics, Electromedical Engineering, and Medical Informatics
Vol 8 No 4 (2026): October

A Disease-Memory Guided Framework for Radiology Report Generation from Multi-View Chest X-rays

Prajakta Dhamanskar (Department of Computer Science and Engineering, Parul University, Gujarat, India)
Chintan Thacker (Department of Computer Science and Engineering, Parul University, Gujarat, India)
Saurabh Shah (Department of Computer Science and Engineering, Parul University, Gujarat, India)



Article Info

Publish Date
10 Oct 2026

Abstract

Chest X-rays are widely used, low-cost diagnostic tools. Writing chest X-ray reports manually is a time-consuming and tedious task. The increasing number of X-rays burdens radiologists, creating a need for a clinically accurate, fast and automated report generation system. To solve this challenge, we propose a new disease-memory-guided vision-language framework for radiology report generation. Frontal and lateral chest X-rays (multi-view) are encoded using a Swin-Transformer. These encoded visual features are then passed through a multi-label classification head that predicts disease probabilities, from which the top three labels are converted into learnable disease-memory embeddings. These are concatenated with projected visual tokens and fixed task instruction embeddings to form a multimodal prompt which is fed into a frozen decoder. A LLaMA-2-7B model adapted to the radiology domain using LoRA fine-tuning on the train-only MIMIC-CXR subset is used as an autoregressive decoder. The disease-memory embeddings serve as disease guidance during report generation. An extensive experimental analysis of different experimental variants is conducted on the benchmark Indiana University Chest X-ray dataset using three aspects: 1) statistical n-gram overlap, 2) semantic similarity, and 3) clinical label-based metrics. Experimental results of the proposed system show improvements in semantic evaluation metrics, with BERTScore precision, recall, and F1 values of 0.898, 0.891 and 0.894, respectively, and ROUGE-L and METEOR scores of 0.327 and 0.281, indicating improved contextual consistency between generated and reference reports. However, performance on statistical metrics (e.g., BLEU4=0.068) and clinical evaluation metrics remains limited, with Micro-F1, Macro-F1, Precision and Recall values of 0.4211, 0.0640, 0.4272, and 0.4151, respectively, indicating only partial abnormality description. This framework improves abnormality grounding while maintaining computational efficiency and can be used as a supportive tool for preliminary report drafting in research or resource-constrained settings.

Copyrights © 2026






Journal Info

Abbrev

jeeemi

Publisher

Subject

Computer Science & IT Control & Systems Engineering Electrical & Electronics Engineering Engineering

Description

The Journal of Electronics, Electromedical Engineering, and Medical Informatics (JEEEMI) is a peer-reviewed open-access journal. The journal invites scientists and engineers throughout the world to exchange and disseminate theoretical and practice-oriented topics which covers three (3) majors areas ...