JKPK (Jurnal Kimia dan Pendidikan Kimia)
Vol 11, No 2 (2026): JKPK (Jurnal Kimia dan Pendidikan Kimia

An RP-HPLC-UV Method for the Determination of Inorganic Mercury (II) via Sulfur-Donor Ligand Complexation and Ion-Pair Retention

Tahir Bakhsh (Department of Chemistry, Faculty of Science, Technology and Mathematics, Universitas Brawijaya, Malang, Indonesia)
Nazhifa Jacinda Maheswari Abidin (Department of Chemistry, Faculty of Science, Technology and Mathematics, Universitas Brawijaya, Malang, Indonesia)
Hermin Sulistyarti (LCAMIA: Research Center for Low Cost and Automated Method & Instrumentation Analysis, Brawijaya University, Malang 65145, Indonesia)
Ani Mulyasuryani (Department of Chemistry, Faculty of Science, Technology and Mathematics, Universitas Brawijaya, Malang, Indonesia)



Article Info

Publish Date
31 Aug 2026

Abstract

Mercury contamination in artisanal and small-scale gold mining regions requires accessible analytical methods, yet established techniques demand dedicated atomic spectrometry instrumentation. This study developed a reversed-phase HPLC-UV method for inorganic mercury(II) based on sulfur-donor ligand complexation and ion-pair retention on a conventional C18 column. Thiocyanate and L-cysteine were evaluated using tetrabutylammonium hydroxide (TBAH) as the ion-pairing reagent. Ultraviolet spectra recorded within the linear response range of the instrument placed the Hg-SCN absorption maximum at 240 nm, and detection was performed at 245 nm. A 1:16 Hg(II): SCN⁻ molar ratio and a final mobile-phase TBAH concentration of 8 mM (acetonitrile 70%, methanol 20%, aqueous TBAH 10% v/v) produced a dominant chromatographic peak. Against an experimentally measured void time of 2.70 min, retention changed regime rather than increasing progressively: the peak eluted before the void volume at 0.5 and 2 mM TBAH (k′ = -0.36) and was retained at 8 mM (k′ = +0.42). Calibration over 0.125-0.500 mM (25.1-100.3 mg/L), using seven independently prepared levels in triplicate, gave R² = 0.9929, an LOD of 0.033 mM (6.5 mg/L) and an LOQ of 0.109 mM (21.8 mg/L), the LOQ lying below the lowest calibration level. Retention-time and peak-area repeatability were 0.80% and 1.96% RSD, and mean recovery from spiked reagent water was 93.8%.  Specificity and matrix effects were not assessed. The validated range lies four orders of magnitude above drinking-water guideline values, so the method is intended as a preliminary procedure for concentrated process and waste streams rather than for environmental monitoring or mercury speciation

Copyrights © 2026






Journal Info

Abbrev

jkpk

Publisher

Subject

Chemical Engineering, Chemistry & Bioengineering Chemistry

Description

The JKPK (Jurnal Kimia dan Pendidikan Kimia) is a national journal, published three times a year in April, August, and December, containing research articles on Chemistry and Chemistry ...