The construction of the lecture building at Tunas Pembangunan University (UTP) Surakarta is one of the facilities needed to create a comfortable and conducive learning environment, while also serving as a representation of the university's identity. The structural design of this lecture building employs a Dual System method. The project site is classified as Site Class D (medium soil condition). The structural analysis was carried out in accordance with SNI 2847:2019 for reinforced concrete design, SNI 1726:2019 for seismic load analysis, and loading requirements based on SNI 1727:2020 and PPPURG 1987. The results of the seismic force distribution analysis for the dual system indicate that the moment-resisting frame carries 83,801% of the base shear force in the X-direction and 59,573% in the Y-direction. Meanwhile, the shear wall carries 16,199% of the base shear force in the X-direction and 40,427% in the Y-direction. The structural design resulted in a roof slab thickness of 120 mm, floor slab thickness of 130 mm, B1 beams measuring 350/600 mm, B2 beams measuring 350/550 mm, B3 beams measuring 300/450 mm, B4 beams measuring 300/400 mm, K1 columns measuring 600/600 mm, K2 columns measuring 500/500 mm, K3 columns measuring 450/450 mm, tie beams measuring 400/500 mm, shear walls with a thickness of 200 mm, retaining walls with a thickness of 200 mm, and bored pile foundations with a diameter of 500 mm and a depth of 9 m.