The construction of the new Muhammadiyah Integrated Elementary School (SDMT) building in Ponorogo is constrained by limited land availability, requiring a three-story structure with adequate capacity to resist gravity and seismic loads. This study aims to design and evaluate the structural performance of the building's superstructure, including the roof structure, slabs, beams, and columns. Structural analysis and design were conducted in accordance with SNI 1726:2019, SNI 1727:2020, SNI 2847:2019, and SNI 1729:2020, while seismic performance was evaluated using the response spectrum method. The results show that the roof structure satisfies the required safety criteria using CNP 150 × 50 × 20 × 3 purlins and IWF 300 × 150 × 6.5 × 9 steel roof trusses. The effective seismic weight reached 1,171,468.86 kg, with an equivalent static base shear of 202,502.85 kg. The structural components fulfilled the design requirements, including reinforced concrete slabs with thicknesses of 10 cm, 13 cm, and 15 cm, primary beams measuring 55 × 30 cm, and primary columns measuring 50 × 40 cm. Overall, the proposed superstructure satisfies the requirements for strength, stiffness, stability, and compliance with applicable Indonesian design standards.