International Journal of Science and Environment
Vol. 6 No. 4 (2026): November 2026

Design-Stage Analytical and CFD Assessment of a Coconut Oil–Fly Ash Composite PCM Partition Wall with Fan-Assisted Ventilation for Tropical Residential Cooling

Aldissain Jurizat (Architecture, Universitas Pendidikan Indonesia, Jl. Dr. Setiabudhi No. 229, Bandung 40154, Indonesia)
Usep Surahman (Architecture, Universitas Katolik Parahyangan, Jl. Ciumbuleuit No. 94, Bandung 40141, Indonesia)
Galuh Kresnadian Tedjawinata (Architecture, Universitas Katolik Parahyangan, Jl. Ciumbuleuit No. 94, Bandung 40141, Indonesia)



Article Info

Publish Date
04 Nov 2026

Abstract

Masonry dwellings in tropical Indonesia often exceed the indoor comfort range on hot afternoons, encouraging reliance on split-unit air conditioning (AC). This study presents a design-stage assessment of a partition wall containing 918 polyethylene spheres (12 cm) filled with a coconut oil–fly ash composite phase change material (PCM; 50 vol% oil, 40 vol% fly ash, 10 vol% air) and assisted by exhaust fans (24 W in total), for two bedrooms of a Type-36 house in Bandung. A Maxwell-Eucken estimate indicates that fly ash raises the composite thermal conductivity from 0.17 to about 0.32 W/m·K (0.24–0.36 W/m·K). A quasi-steady melting analysis shows that capsule charging is limited mainly by surface convection: the latent heat absorbed during a 5-h afternoon (2.0–3.7 kWh for the whole wall) is similar to that of pure-oil capsules, while the composite uses 44% less oil and completes its melting cycle faster. The installed 373.8 kg of oil corresponds to a theoretical air-temperature reduction of up to 4.0 °C in the 49.5 m³ rooms. A steady-state CFD simulation (Butterfly/OpenFOAM) for the EPW design hour (9 December, 14:00; outdoor 29.0 °C), with the PCM surface prescribed at 25.5 °C, gives an indoor air temperature of 26.33 °C against 28.30 °C for brick partitions, within the ASHRAE 55 adaptive comfort limits. Operating electricity and CO₂ emissions are 95–97% lower than for two ½ PK AC units, with a simple payback of about 3.3 years; as the AC provides lower temperatures and dehumidification, these are upper bounds. Transient coupled simulation and prototype testing are required for validation.

Copyrights © 2026






Journal Info

Abbrev

IJSE

Publisher

Subject

Agriculture, Biological Sciences & Forestry Biochemistry, Genetics & Molecular Biology Chemical Engineering, Chemistry & Bioengineering Chemistry Mathematics Physics

Description

International Journal of Science and Environment (IJSE) is to provide a research medium and an important reference for the advancement and dissemination of research results that support high-level research in the fields of Science and Environment . Original theoretical work and application-based ...