The oil and gas industry requires effective maintenance systems to ensure equipment reliability and reduce downtime. A choke valve controls fluid flow and pressure but is vulnerable to erosion, leakage, actuator short circuits, corrosion, and blockage. This study identifies failure modes, analyzes their causes and effects, and prioritizes choke valve maintenance using Failure Mode and Effect Analysis (FMEA). A quantitative descriptive study was conducted at PT Pertamina EP from January to June 2024. Data were collected through observations, interviews, failure records, maintenance reports, and downtime records. Risk was assessed using Severity, Occurrence, and Detection ratings to calculate the Risk Priority Number (RPN). Nine failure events were recorded, totaling 60.6 hours of downtime, averaging 6.73 hours per event. The trim was the most critical component, followed by the seal and actuator. Preventive maintenance, regular inspections, and suitable material selection are recommended to reduce failure risks and improve overall choke valve reliability.