Journal of Chemical Engineering Research Progress
2026: Just Accepted Manuscript and Article In Press 2026

Sensitivity Improvement of an In-Line Electromagnetic Metal Detector for Chemical Process Streams Using a Radial Basis Function Neural Network

Hyok Jo (Department of Control Science, University of Science, Pyongyang 355)
CholJin O (Department of Control Science, University of Science, Pyongyang 355)
GumHyok Pak (Department of Control Science, University of Science, Pyongyang 355)
Jusong Rim (Department of Control Science, University of Science, Pyongyang 355)
Boknam Huang (Department of Control Science, University of Science, Pyongyang 355)
CholRyong Huang (Department of Control Science, University of Science, Pyongyang 355)



Article Info

Publish Date
30 Jun 2027

Abstract

Tramp-metal contamination in chemical process streams damages crushers, mills, and extruders, degrades product purity, and can provide ignition sources in combustible-dust atmospheres. In-line electromagnetic induction (EMI) metal detectors are the standard countermeasure, but their practical sensitivity is limited by the product effect—the channel-correlated background signal produced by conductive or moist process materials—which forces conservative detection thresholds and causes false alarms or missed small fragments. This paper presents an in-line EMI metal detector whose sensitivity and false-alarm stability are improved by a radial basis function (RBF) neural network that estimates the size and cross-sectional position of a metallic fragment from the induced voltages of a six-coil array mounted on a process pipe. A prototype was dynamically validated over 200 passes with 125 metallic objects, achieving 99.2% detection accuracy and a 3 mm minimum detectable radius. Because the prototype's component-level documentation is no longer available, a fully parameterized simulation of the in-line configuration was conducted with representative design values and a product-effect model: on 2400 training and 1500 test samples, the RBF network matched a conventional amplitude-threshold detector at the nominal product level (AUC 0.949 versus 0.962) while a two-hidden-layer multilayer perceptron baseline performed comparably (AUC 0.945); the decisive advantage appeared under product-effect drift, where the false-alarm rate of the RBF detector rose to only 20.3% at 2.5× the nominal product level against 71.1% for the amplitude threshold, without recalibration. The RBF estimator also localized fragments with a mean absolute error of 2.0 mm (pipe radius 45 mm), an estimation capability the threshold detector does not provide. These results indicate that a lightweight trained estimator can substantially improve the operability of in-line metal detection in chemical plants.

Copyrights © 2026






Journal Info

Abbrev

jcerp

Publisher

Subject

Chemical Engineering, Chemistry & Bioengineering Energy Engineering Materials Science & Nanotechnology

Description

The Journal of Chemical Engineering Research Progress (e-ISSN: 3032-7059; Short Abbreviation Title: J. Chem. Eng. Res. Prog.) is an international research journal and invites contributions of original and novel fundamental research. The JCERP journal aims to provide an international forum for the ...