Journal of Electronics, Electromedical Engineering, and Medical Informatics
Vol 8 No 4 (2026): October

Embedded Colour- and Electrodermal-Based Pressure Injury Staging and Objective Pain Assessment System Powered by a Proton Battery

Wahmisari Priharti (Advanced Biomedical Intelligent Engineering Laboratory, Biomedical & Healthcare Technology Center of Excellence, School of Electrical Engineering, Telkom University, Bandung, Indonesia)
Husneni Mukhtar (Advanced Biomedical Intelligent Engineering Laboratory, Biomedical & Healthcare Technology Center of Excellence, School of Electrical Engineering, Telkom University, Bandung, Indonesia)
Dien Rahmawati (Advanced Biomedical Intelligent Engineering Laboratory, Biomedical & Healthcare Technology Center of Excellence, School of Electrical Engineering, Telkom University, Bandung, Indonesia)
Nur Hidayah Ahmad (Advanced Optical Materials Research Group, Department of Physics, Faculty of Science, Universiti Teknologi Malaysia, Skudai, Malaysia Corresponding author: W.)



Article Info

Publish Date
30 Oct 2026

Abstract

Pressure injury is a serious health concern among the elderly and individuals with restricted mobility and is often associated with pain that reduces quality of life. Conventional assessment relies on clinician visual inspection and subjective pain scales, which are difficult to apply to patients with limited communication abilities. Therefore, early identification, accurate stage classification and objective pain assessment are essential for effective clinical intervention. This study develops an embedded pressure injury stage classification and pain assessment system integrating a colour sensor and an electrodermal activity (EDA) sensor with a Rule-Based Decision Tree to classify pressure injuries into four clinical stages, powered by a six-cell 1.5 V proton battery pack as an alternative to conventional lithium-based power sources. The system achieved an overall accuracy, precision, recall, and F1-score of 0.88, 0.89, 0.88, and 0.88, respectively. Skin Conductance Level (SCL) increased progressively from Stage 1 to Stage 3 and decreased at Stage 4, indicating a preliminary physiological pattern associated with injury severity. The battery pack maintained a stable output voltage of 9.1 V at an average current consumption of 279.9 mA, demonstrating its feasibility as an alternative power source. Because the thresholds were derived from 70 annotated Medetec images and validated on only two subjects with four injury sites (40 region-level measurements), the reported metrics should be interpreted as preliminary proof-of-concept rather than definitive clinical validation, and larger studies are needed for clinical confirmation.

Copyrights © 2026






Journal Info

Abbrev

jeeemi

Publisher

Subject

Computer Science & IT Control & Systems Engineering Electrical & Electronics Engineering Engineering

Description

The Journal of Electronics, Electromedical Engineering, and Medical Informatics (JEEEMI) is a peer-reviewed open-access journal. The journal invites scientists and engineers throughout the world to exchange and disseminate theoretical and practice-oriented topics which covers three (3) majors areas ...