This study assessed whether the sequencing batch reactor (SBR) system at the wastewater treatment plant (WWTP) of Dr. Tjitrowardojo Regional General Hospital in Purworejo had sufficient capacity to accommodate daily wastewater flows and evaluated its treatment performance using influent and effluent laboratory results against the standards specified in Minister of Environment and Forestry Regulation No. 68 of 2016. A quantitative descriptive approach was adopted. Influent and effluent grab samples were collected over three months (March–May 2026) and analyzed at the Health Laboratory and Calibration Center (BLKK) of the Special Region of Yogyakarta. Treatment capacity was assessed by comparing actual flows with the maximum plant capacity, while treatment performance was evaluated using removal efficiencies for pH, biochemical oxygen demand (BOD), chemical oxygen demand (COD), total suspended solids (TSS), oil and grease, ammonia, and total coliforms. The maximum treatment capacity was 306 m³/day, whereas the mean actual flow was only 113.81 m³/day, indicating that the available capacity remained adequate. Effluent quality met the standards specified in Minister of Environment and Forestry Regulation No. P.68/MENLHK/SETJEN/KUM.1/8/2016. High removal efficiencies were reported for BOD (76.50–97.99%), COD (45.95–96.49%), TSS (70.00–83.33%), ammonia (91.43–96.88%), and total coliforms (>99.97%). Overall, the WWTP continued to treat wastewater effectively using the SBR system after approximately 26 years of operation.