Residence time is a key control variable in continuous torrefaction because it determines the duration of biomass exposure to the thermal environment. This study develops a pulley-driven method that converts a target residence time into screw rotational speed, driving-pulley diameter, and belt length without changing the reactor body or gearbox. Three targets (10, 20, and 30 min) were designed for a continuous oil-jacketed tubular screw reactor with a 1:60 gearbox and validated experimentally. Each pulley configuration was tested in five repeated residence-time measurements using a 100 g test charge and manual stopwatch timing. The designed pulley diameters were 10.9, 19.33, and 29 cm, with corresponding belt lengths of 133.32, 147.80, and 164.54 cm. Experimental residence times were 9.85 ± 0.54, 20.71 ± 0.49, and 30.06 ± 0.35 min (mean ± SD, n = 5), corresponding to absolute mean errors of 1.50%, 3.55%, and 0.20%, respectively. The results show that discrete pulley replacement can provide repeatable, mechanically simple residence-time settings under the tested conditions. The contribution is a transparent design-to-validation workflow linking target residence time directly to transmission geometry. Because feedstock properties and full thermal operating conditions were not independently characterized in the validation dataset, the findings should be interpreted as validation of mechanical residence-time control rather than torrefaction-product performance.
Copyrights © 2026