Healthy Tadulako Journal (Jurnal Kesehatan Tadulako)
Vol. 12 No. 4 (2026)

Development of an Instrument to Assess Service Quality and Resource Adequacy in Midwifery Laboratories

Hidayanti Arifuddin (Department of Midwifery, Poltekkes Kemenkes Jakarta I, Jakarta, Indonesia)
A Fahira Nur (Department of Midwifery, Widya Nusantara University, Palu, Indonesia)
Nur Dwi Yulianti (Department of Midwifery, Poltekkes Kemenkes Jakarta I, Jakarta, Indonesia)
Devi Devinda Novitasari (Department of Midwifery, Poltekkes Kemenkes Jakarta I, Jakarta, Indonesia)
Charisma Destrikasari (Department of Midwifery, Poltekkes Kemenkes Jakarta I, Jakarta, Indonesia)
Wulan Anjani (Department of Midwifery, Poltekkes Kemenkes Jakarta I, Jakarta, Indonesia)
Putri Yuniartis (Department of Midwifery, Poltekkes Kemenkes Jakarta I, Jakarta, Indonesia)
Mita Herlina Sari (Department of Midwifery, Poltekkes Kemenkes Jakarta I, Jakarta, Indonesia)
Siti Rahmadani Nasution (Department of Midwifery, Poltekkes Kemenkes Jakarta I, Jakarta, Indonesia)
Adhar Arifuddin (Department of Epidemiology, Faculty of Public Health, Tadulako University, Palu, Indonesia)



Article Info

Publish Date
31 Oct 2026

Abstract

Background: Midwifery laboratories are essential for developing clinical competencies, yet service quality and resource adequacy are frequently assessed separately. Objectives: This study aimed to develop and internally evaluate an integrated instrument for assessing midwifery laboratory quality. Methods: Five experts validated the instrument, and 446 midwifery students with laboratory experience completed a 44 item questionnaire. Psychometric evaluation included content validity, exploratory factor analysis (EFA), preliminary confirmatory factor analysis (CFA), Rasch analysis, and internal consistency testing. Results: The average scale content validity index was 0.982. EFA identified six factors explaining 56.96% of total variance, with the first factor contributing 44.02%. Preliminary CFA demonstrated X²/df = 2.240, RMSEA = 0.053, SRMR = 0.041, GFI = 0.991, CFI = 0.898, and TLI = 0.886. Rasch person reliability was 0.969, whereas item reliability was 0.641. Cronbach alpha reached 0.970, with corrected item total correlations ranging from 0.561 to 0.739. Conclusions: The instrument demonstrated promising internal psychometric properties for evaluating midwifery laboratory quality. However, independent external validation and comprehensive ordinal and Rasch diagnostics remain necessary before broader implementation.

Copyrights © 2026






Journal Info

Abbrev

htj

Publisher

Subject

Dentistry Health Professions Medicine & Pharmacology Nursing Public Health

Description

Healthy Tadulako Journal (Jurnal Kesehatan Tadulako) merupakan media komunikasi dan publikasi ilmiah di bidang ilmu kesehatan yang diterbitkan oleh Unit Penjaminan Mutu Fakultas Kedokteran Universitas Tadulako yang. Jurnal ini terbit secara berkala 4 kali dalam setahun (Januari, April, Juli dan ...