Early detection of vaso-occlusive crises remains challenging because crisis onset is multifactorial and physiological responses vary across patients. This study evaluates a fuzzy-fusion method that combines six patient-centered biometric deviations with measurement-quality and contextual information to produce a continuous pre-crisis ranking score. The analysis included 500 patients and 321,988 15-minute windows after exclusion of active-crisis windows. A window was labeled positive when the next recorded vaso-occlusive crisis began within 30 minutes after the window end. Patients were separated between training and testing (375/125), and decision thresholds were selected on the training set. The test set contained 216 positive windows among 80,842 windows (0.27%). Fuzzy fusion achieved a PR AUC of 0.642, F1-score of 0.642, precision of 0.581, and recall of 0.718, compared with PR AUC 0.343 and F1-score 0.496 for hard thresholds. Logistic regression achieved the highest discrimination (PR AUC 0.787; F1-score 0.652), whereas fuzzy fusion generated fewer false-positive windows at its training-derived operating point. The fuzzy score was not well calibrated as a probability and should be interpreted as an ordinal risk index. The results support methodological feasibility and auditability, not clinical validation.