Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics
Vol. 8 No. 4 (2026): November

Analyzing the Contribution of Bioimpedance and Laboratory Feature Groups to Machine Learning-Based Gallstone Disease Classification

Leo Cristian Ferry (Department of Informatics, Universitas Negeri Surabaya, Surabaya, Indonesia)
Yuni Yamasari (Department of Informatics, Universitas Negeri Surabaya, Surabaya, Indonesia)



Article Info

Publish Date
16 Nov 2026

Abstract

Gallstone disease classification using structured patient data can benefit from different measurement sources, but the contribution of complete bioimpedance and laboratory feature groups beyond routine variables remains unclear. This study compared predefined measurement groups, rather than selecting individual predictors, to assess their incremental predictive value and consistency across models. The UCI Gallstone Dataset contained 319 participants and 38 predictors assigned to demographic, clinical, bioimpedance, and laboratory groups. Four scenarios combined a demographic and clinical baseline with bioimpedance, laboratory measurements, or both. Logistic Regression, Support Vector Machine, Random Forest, and XGBoost were tuned using GridSearch and Sand Cat Swarm Optimization (SCSO). Each optimizer used 100 fitness evaluations based on stratified five-fold cross-validation within the training data, followed by evaluation on the same held-out test set of 64 participants. Stability was examined across five repeated stratified partitions for GridSearch and five independent SCSO seeds on the original partition, while uncertainty was assessed using 4,000 stratified paired bootstrap resamples. Averaged across classifiers, adding bioimpedance improved held-out accuracy by 0.195 with GridSearch and 0.211 with SCSO; corresponding gains for laboratory measurements were 0.242 and 0.254. Mean ROC-AUC gains were 0.240 and 0.261 for bioimpedance and 0.303 and 0.327 for laboratory measurements. The highest held-out accuracy was 0.797 for Logistic Regression in Scenario C under both optimizers and Scenario D under SCSO; the best F1-score (0.817) and ROC-AUC (0.886) occurred in Scenario D with SCSO and GridSearch, respectively. Bootstrap intervals supported both additions to the baseline, but did not establish that laboratory gains were statistically greater than bioimpedance gains. The incremental value of bioimpedance after laboratory measurements remained uncertain. Neither optimizer consistently outperformed the other on held-out data. These findings require external validation because they derive from a small, single-center dataset.

Copyrights © 2026






Journal Info

Abbrev

ijeeemi

Publisher

Subject

Computer Science & IT Control & Systems Engineering Decision Sciences, Operations Research & Management Electrical & Electronics Engineering Health Professions Materials Science & Nanotechnology

Description

Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics (IJEEEMI) publishes peer-reviewed, original research and review articles in an open-access format. Accepted articles span the full extent of the Electronics, Biomedical, and Medical Informatics. IJEEEMI seeks to ...