Indonesian Journal of Clinical Pathology and Medical Laboratory (IJCPML)
Vol. 33 No. 1 (2026)

Accuracy of Thromboelastography in The Diagnosis of Sepsis-Induced Coagulopathy

Siti Fatonah (Department of Clinical Pathology, Faculty of Medicine, Universitas Brawijaya/Dr. Saiful Anwar General Hospital, Malang)
Juan Aditya (Faculty of Medicine, Universitas Brawijaya/Dr. Saiful Anwar General Hospital, Malang)
Nikmatus Sholihah (Department of Clinical Pathology, Faculty of Medicine, Universitas Islam Malang, Malang)



Article Info

Publish Date
10 Nov 2026

Abstract

Coagulopathy is a significant factor associated with mortality in septic patients. Thromboelastography (TEG) enables global, dynamic monitoring of coagulation alterations in this population. This study aimed to evaluate the correlation between TEG parameters and Sepsis-Induced Coagulopathy (SIC) scores and to determine TEG's diagnostic utility in identifying coagulopathy in septic patients. We enrolled a prospective cohort of 27 sepsis patients admitted to the Intensive Care Unit (ICU) of Dr. Saiful Anwar General Hospital, Malang. Patients with severe hepatic and renal dysfunction, malignancies, pre-existing hemostatic disorders, or recent antiplatelet/anticoagulant therapy were excluded. We stratified subjects into SIC and non-SIC groups based on clinical scoring. We assessed diagnostic efficacy using Receiver Operating Characteristic (ROC) curve analysis. We observed significant correlations between TEG parameters and SIC scores. The Coagulation Index (CI), Maximum Amplitude (MA), and alpha (α) angle were significantly decreased in the SIC cohort (p<0.05), whereas the K time was significantly prolonged (p<0.05). Conversely, the R time did not demonstrate a statistically significant correlation (p>0.05). ROC analysis showed strong diagnostic performance for individual TEG parameters, with MA (AUC=0.921), followed by K Time (AUC=0.893), α angle (AUC=0.881), and CI (AUC=0.837). The optimal diagnostic cut-off thresholds determined via the Youden index were: MA ≤ 57.7 mm (sensitivity 100%, specificity 81%); K Time ≥ 2.5 minutes (sensitivity 100%, specificity 71.4%); α angle ≤58.05° (sensitivity 100%, specificity 71.4%); and CI ≤-1.35 (sensitivity 83.3%, specificity 71.4%). TEG effectively evaluates and diagnoses coagulopathy in septic patients, with the Maximum Amplitude (MA) parameter providing the highest diagnostic accuracy.

Copyrights © 2026






Journal Info

Abbrev

patologi

Publisher

Subject

Biochemistry, Genetics & Molecular Biology Health Professions Medicine & Pharmacology Neuroscience

Description

Indonesian Journal of Clinical Pathology and Medical Laboratory (IJCPML) is a journal published by “Association of Clinical Pathologist” professional association. This journal displays articles in the Clinical Pathology and Medical Laboratory scope. Clinical Pathology has a couple of ...