JTAM ROTARY
Vol 8, No 2 (2026): JTAM ROTARY

MODIFIKASI DAN PENGATURAN PUTARAN MOTOR PENGGERAK KOMPRESOR PADA ALAT PERAGA SISTEM AC MOBIL

Dzaka Yusuf Arifian (Politeknik Negeri Malang)
Nurhadi Nurhadi (Politeknik Negeri Malang)



Article Info

Publish Date
16 Nov 2026

Abstract

Penelitian ini bertujuan memodifikasi sistem penggerak kompresor pada trainer AC mobil dengan menggunakan motor induksi tiga fasa yang dikendalikan melalui Variable Frequency Drive (VFD). Modifikasi dilakukan terhadap sistem penggerak, komponen refrigerasi yang mengalami kerusakan, serta jalur refrigeran yang mengalami kebocoran. Setelah proses perbaikan, sistem divakum, diisi refrigeran R134a, dan diuji pada tiga tingkat putaran motor, yaitu rendah, sedang, dan tinggi. Hasil pengujian fungsional menunjukkan bahwa VFD mampu mengendalikan putaran motor dan kompresor pada ketiga kondisi operasi. Secara kualitatif, kondisi putaran rendah menghasilkan getaran rendah, kondisi putaran sedang menunjukkan operasi paling stabil, sedangkan kondisi putaran tinggi menghasilkan peningkatan getaran dan kebisingan. Sistem AC dapat kembali beroperasi setelah proses modifikasi. Namun, evaluasi kuantitatif terhadap tekanan, temperatur, getaran, kebisingan, serta kapasitas pendinginan masih diperlukan untuk menentukan pengaruh putaran kompresor terhadap performa sistem secara lebih komprehensif. This study aimed to modify the compressor drive system of an automotive air-conditioning trainer by using a three-phase induction motor controlled through a Variable Frequency Drive (VFD). The modification involved the drive system, damaged refrigeration components, and leaking refrigerant lines. After the repair process, the system was evacuated, charged with R134a refrigerant, and tested at three motor-speed levels: low, medium, and high. Functional testing showed that the VFD was capable of controlling both the motor and compressor speeds under all three operating conditions. Qualitatively, the low-speed condition produced low vibration, the medium-speed condition provided the most stable operation, while the high-speed condition resulted in increased vibration and noise. The air-conditioning system was successfully restored to operation after the modification. However, further quantitative evaluation of pressure, temperature, vibration, noise, and cooling capacity is required to determine the effect of compressor speed on overall system performance more comprehensively.

Copyrights © 2026






Journal Info

Abbrev

rot

Publisher

Subject

Control & Systems Engineering Energy Industrial & Manufacturing Engineering Materials Science & Nanotechnology Mechanical Engineering

Description

JTAM Rotary diterbitkan oleh Program Studi Teknik Mesin Fakultas Teknik Universitas Lambung Mangkurat. JTAM Rotary merupakan jurnal terbuka yang dapat diakses siapapun, baik itu peneliti, akademisi, dan praktisi di bidang teknik mesin. JTAM Rotary terbit dua kali dalam setahun, yaitu pada bulan ...