International Journal of Innovation in Mechanical Engineering and Advanced Materials
Vol. 8 No. 3 (2026)

Comparative Assessment of Industrial Heat Pump Configurations for Spray Drying Dairy Manufacturing

Imron Afandi (Universitas Muhammadiyah Malang)
A. Hakim Ermanu (Universitas Muhammadiyah Malang)
Sulianto (Universitas Muhammadiyah Malang)
Noufal Haneef (University of Muhammadiyah Malang)
Alrafly Rizky Putra Henryansyah (State University of Surabaya)



Article Info

Publish Date
22 Nov 2026

Abstract

Heat pumps (HPs) are a key route to industrial decarbonization through electrification, but selecting a configuration requires more than maximizing thermodynamic performance: a highly efficient system may still be unable to supply the steam pressure and temperature that a process needs. Few studies evaluate HP configurations by combining thermodynamic performance with process delivery capability. This study compares four configurations of increasing complexity with a boiler–chiller baseline: (C1) boiler feedwater preheating, (C2) a simultaneous heating and cooling HP, (C3) a two-stage cascade high-temperature HP (HTHP), and (C4) a cascade HTHP with mechanical vapor recompression (MVR). The case is a dairy spray-drying plant that requires 12 barg steam (4 t/h) and 250 TR of cooling. Energy and exergy analyses used IAPWS-IF97 properties and the Gouy–Stodola formulation. Each COP was tested against its Lorenz limit and replaced by a cycle-based value where inadmissible, and C3 was modelled independently of C4. At the design point, exergy efficiency rose from 25.5% (baseline) to 27.4% (C1), 29.1% (C2), 34.5% (C3) and 42.2% (C4). Only C4 delivered 12 barg steam; C3 supplied saturated steam at 4 barg (152 °C). The vendor quoted COP of C2 (5.3) exceeded its Lorenz limit (5.12) and was replaced by a cycle-calculated value of 2.56. Operational CO₂ emissions of C3 and C4 exceed those of the baseline when the grid emission factor is above about 0.30 t CO₂/MWh (0.88 t CO₂/MWh was adopted). Delivery-envelope compliance and exergy efficiency are independent criteria: compliance is decided by the final steam pressure, whereas the exergy efficiency of C3 ranged from 31.6% to 60.0% across the sensitivity grid without changing its 4 barg limit. The proposed framework checks delivery-envelope compliance first and Lorenz-consistent thermodynamic performance second, allowing unsuitable configurations to be excluded before detailed techno-economic design.

Copyrights © 2026






Journal Info

Abbrev

ijimeam

Publisher

Subject

Automotive Engineering Energy Engineering Materials Science & Nanotechnology Mechanical Engineering

Description

The journal publishes research manuscripts dealing with problems of modern technology (power and process engineering, structural and machine design, production engineering mechanism and materials, etc.). It considers activities such as design, construction, operation, environmental protection, etc. ...