The Indonesian Archipelagic Sea Lane II (ALKI II) is a vital maritime transportation route for energy commodities, making the structural reliability of barges operating in this area critical. The non-uniform corrosion phenomenon on ship plates can potentially trigger structural failure due to random and unpredictable thinning patterns. This study aims to evaluate the structural integrity, stress redistribution, and deformation of the bottom plate of a barge measuring 91.5 m x 24.4 m x 5.5 m. Experimental data were obtained via non-destructive testing (NDT) using an Ultrasonic Thickness Gauge across 132 grid points spaced 300 mm apart on an existing 6600 x 1800 x 14 mm plate. This actual topology data was integrated into a Finite Element Method (FEM) numerical model, applying a hydrodynamic bottom pressure load of 0.0734 N/mm2. Field inspection results revealed plate thickness variations due to non-uniform corrosion ranging from 10.6 mm to 13.4 mm. From the FEM simulation with a mesh convergence size of 35 mm, a maximum deformation of 2.17676 mm was obtained in the plate region with a thickness of 10.6 mm. Meanwhile, the maximum equivalent stress was recorded at 86.982 MPa at node 12261 in the scallop area. This actual stress value remained below the allowable stress limit set by the Indonesian Classification Bureau (BKI) regulations of 150 MPa. In conclusion, despite experiencing local thinning due to non-uniform corrosion, the bottom plate structure of the barge is declared safe, technically seaworthy, and free from the risk of immediate structural failure.