Reusing treated domestic wastewater for landscape irrigation requires assessing effluent quality. This study evaluated the preliminary suitability of domestic wastewater effluent from a residential facility in Makassar, Indonesia. A descriptive quantitative approach compared six parameters measured in September 2026 with Indonesian wastewater reuse criteria and calculated concentration-to-limit ratios. The effluent had a pH of 6.71, BODâ‚… of 7 mg/L, COD of 54 mg/L, TSS of 4 mg/L, residual chlorine of 0.5 mg/L, and fecal coliforms of 180 MPN/100 mL. All measured parameters met the selected numerical criteria. Fecal coliforms and COD had the highest ratios (0.900 and 0.675, respectively), identifying monitoring priorities based on proximity to thresholds. These findings support preliminary consideration of the effluent for landscape irrigation. Integrating effluent quality control with irrigation demand and site conditions would support reuse planning and evaluation of potential freshwater savings.
Copyrights © 2026