DT8 serves as the basis for a normalization plan derived from the design flood discharge. Rainfall intensity was calculated using the Mononobe method, while the design flood discharge was determined using the Rational Method. Subsequently, channel capacity was analyzed using Manning's equation, incorporating cross-sectional area, wetted perimeter, hydraulic radius, channel slope, and Manning's roughness coefficient. The results indicate that the Log Pearson Type III distribution was the most suitable fit; the design flood discharges for return periods of 5, 10, 25, 50, and 100 years were 25.18 m³/s, 30.20 m³/s, 36.55 m³/s, 41.25 m³/s, and 45.92 m³/s, respectively. Meanwhile, the capacity of the DT8 drainage channel is 20,361 m³/s, meaning the channel can only accommodate the design flood discharge for a two-year return period. Sediment accumulation reduces flow capacity if left unaddressed. Therefore, normalization through sediment dredging and routine maintenance is recommended to preserve channel capacity and mitigate the risk of future inundation.