Excessive vibration in vertically mounted industrial agitators can accelerate degradation of bearings, shafts, gearboxes, and supporting structures. This retrospective industrial study compares vibration measurements obtained before and after a structural support retrofit on a variable-speed vertical agitator used in a cement grinding-aid process. The two campaigns were conducted on different dates and with different vibration analysers; therefore, the observed differences are not interpreted as an isolated causal retrofit effect. At measurement point 1, horizontal vibration increased from 1.6 mm/s at 82 rpm to 13.0 mm/s at 203 rpm before the retrofit, whereas the post-retrofit campaign recorded 2.5 mm/s at 200 rpm, an observed before-and-after difference of 80.8%. At 50 Hz, points 2 and 3 changed from 6.2 to 1.7 mm/s and from 6.3 to 1.5 mm/s, respectively. Post-retrofit spectra and thermography are presented only as condition indicators; the largest reported looseness-related component was 0.84 m/s², and full-load motor temperature reached 66.3-67.7°C. The field evidence is associated with lower vibration levels following the support modification, while the dataset limitations preclude confirmation of resonance shifts or a uniquely causal mechanism.