Seminar Nasional Teknologi Informasi Komunikasi dan Industri
2012: SNTIKI 4

Perhitungan Rerating Motor Induksi Akibat Tegangan Tidak Seimbang Dengan Metode William

Darmansyah Darmansyah (Jurusan Teknik Elektro Fakultas Teknik Universitas Lancang Kuning)



Article Info

Publish Date
03 Oct 2012

Abstract

Three-phase induction motor is one of the electric motor is in operation requires three-phase supply voltage is balanced to operate optimally. Three-phase supply voltages are un balanced can reduce the rating of the three-phase induction motor during operation.To calculate the rerating three-phase induction motor output due to supply voltage three-phase unbalanced done using the method of William. Unbalanced three-phase voltage obtained by simulation. Simulation is used Monte Carlo simulations to present three-phase induction motor condition with input voltages to the stator is unbalanced using the software MATLAB 7.The results of calculations show the influence of unbalanced input voltage by a factor of 0.76% voltage imbalance – 8.41% of a three-phase induction motor rating can be seen in the form of a decrease in the power rating of three-phase induction motor 10 hp to 9.45 – 4.03 hp.Keywords: rerating, Monte Carlo simulation, Method of William

Copyrights © 2012






Journal Info

Abbrev

SNTIKI

Publisher

Subject

Computer Science & IT Control & Systems Engineering Electrical & Electronics Engineering Industrial & Manufacturing Engineering Mathematics

Description

SNTIKI adalah Seminar Nasional Teknologi Informasi, Komunikasi dan Industri yang diselenggarakan setiap tahun oleh Fakultas Sains dan Teknologi Universitas Islam Negeri Sultan Syarif Kasim Riau. ISSN 2579 7271 (Print) | ISSN 2579 5406 ...