Jurnal Purifikasi
Vol 11 No 1 (2010): Jurnal Purifikasi

APLIKASI MEMBRAN JENIS SPIRAL-WOUND PADA PENGOLAHAN LIMBAH CAIR SEKUNDER

Subriyer Nasir (Unknown)



Article Info

Publish Date
11 Apr 2018

Abstract

Study on secondary effluent treatment from Kwinana Water Reclamation Plant (KWRP), Western Australia, was done in small scale Reverse Osmosis (RO) system with a capacity of 2000 L/d. The RO system was equipped with two spiral wound membrane module. Effect of operating pressures and build-up of sodium and calcium ions on membrane surface were important subjects in this research. Results of this study showed that permeate flux, rejection percentage of Total Organic Carbon (TOC) and Total Dissolved Solids (TDS) were significantly affected by operating pressure. However, percentage of water recovery could be achieved only around 48% at an operating pressure of 3250 kPa.

Copyrights © 2010






Journal Info

Abbrev

purifikasi

Publisher

Subject

Chemical Engineering, Chemistry & Bioengineering Environmental Science

Description

Jurnal Purifikasi was published since January 2000 by Division of Journal Purifikasi Department of Environmental Engineering-Faculty of Civil, Environment and Geo Engineering. Institut Teknologi Sepuluh Nopember, Surabaya in collaboration with the Association of Indonesian Sanitary and Environmental ...