PHARMACY: Jurnal Farmasi Indonesia (Pharmaceutical Journal of Indonesia)
Jurnal Pharmacy, Vol. 06 No. 02 Agustus 2009

PENETAPAN KADAR KLORAMFENIKOL DALAM TETES MATA PADA SEDIAAN GENERIK DAN MERK DENGAN METODE KROMATOGRAFI CAIR KINERJA TINGGI

Febriyanti Diah Puspita Sari (Unknown)
Pri Iswati Utami (Unknown)



Article Info

Publish Date
01 Aug 2009

Abstract

ABSTRAK Telah dilakukan penetapan kadar kloramfenikol dalam tetes mata pada sediaan generik dan merk menggunakan Kromatografi Cair Kinerja Tinggi (KCKT) fase terbalik dengan detektor ultraviolet pada panjang gelombang 280 nm. Fase diam yang digunakan adalah kolom Shimpack ODS CLC C18, fase gerak metanol:air (40:60) dengan kecepatan alir 1 mL/menit. Penentuan linearitas dengan kurva baku menunjukkan hubungan yang linier antara luas puncak dan konsentrasi baku kloramfenikol dengan konsentrasi 10-30 µg/mL (r=0,990). Persamaan regresi yang diperoleh adalah y=1,6429x- 5,5758. Nilai limit of detection (LOD) sebesar 5,2 µg/mL dan nilai limit of quantitation (LOQ) sebesar 17,3 µg/mL. Uji presisi memberikan hasil nilai koefisien variasi sebesar 5,988%. Hasil penetapan kadar kloramfenikol dalam tetes mata pada sediaan generik adalah 117,6% dan dalam tetes mata bermerek sebesar 111,29%. Berdasarkan pengujian, sampel tetes mata generik dan bermerek memenuhi persyaratan yang tertera pada Farmakope Indonesia edisi IV. Kata kunci: kloramfenikol, KCKT, tetes mata ABSTRACT Determination of Chloramphenicol in generic and branded eye drop had been carried out by reversed phase high performance liquid chromatography (HPLC) method with UV detector (280 nm). The Shimpack ODS CLC C18 column was used as stationary phase, methanol:water (40:60) v/v as mobile phase, with flow rate 1 mL/minute. Determination of calibration curve linearity showed linear correlation between the peak area and concentration at 10-30 µg/mL with correlation coefficient r=0.990. The equation of regression was y=1.6429x – 5.5758 with LOD and LOQ were 5.2 and 17.3 µg/mL respectively. The precision test showed coefficient variation (CV) was 5.988%. The average chloramphenicol content of generic and branded product were 117.6 and 111.29% respectively. The sample was fulfilled the requirement of Farmakope Indonesia fourth edition. Keywords: chloramphenicol, reversed phase HPLC, eye drop.

Copyrights © 2009






Journal Info

Abbrev

PHARMACY

Publisher

Subject

Materials Science & Nanotechnology

Description

PHARMACY: Jurnal Farmasi Indonesia (Pharmaceutical Journal of Indonesia) is a scientific journal publishing original articles research in pharmaceutical science such as Pharmaceutical Technology, Pharmacology and Toxicology, Pharmaceutical Chemistry, Drug Discovery, Pharmacokinetics, Pharmaceutical ...