Bulletin of Electrical Engineering and Informatics
Vol 8, No 2: June 2019

Hand Motion Pattern Recognition Analysis of Forearm Muscle using MMG Signals

R. Mohamad Ismail, M. ( Universiti Malaysia Perlis)
K. Lam, C. ( Universiti Malaysia Perlis)
Sundaraj, K. ( Universiti Teknikal Melaka)
H. F. Rahiman, M. ( Universiti Malaysia Perlis)



Article Info

Publish Date
01 Jun 2019

Abstract

Surface Mechanomyography (MMG) is the recording of mechanical activity of muscle tissue. MMG measures the mechanical signal (vibration of muscle) that generated from the muscles during contraction or relaxation action. It is widely used in various fields such as medical diagnosis, rehabilitation purpose and engineering applications. The main purpose of this research is to identify the hand gesture movement via VMG sensor (TSD250A) and classify them using Linear Discriminant Analysis (LDA). There are four channels MMG signal placed into adjacent muscles which PL-FCU and ED-ECU. The features used to feed the classifier to determine accuracy are mean absolute value, standard deviation, variance and root mean square. Most of subjects gave similar range of MMG signal of extraction values because of the adjacent muscle. The average accuracy of LDA is approximately 87.50% for the eight subjects. The finding of the result shows, MMG signal of adjacent muscle can affect the classification accuracy of the classifier.