Ketenagalistrikan dan Energi Terbarukan
Vol 13, No 2 (2014): KETENAGALISTRIKAN DAN ENERGI TERBARUKAN

ANALISIS PENGUJIAN KINERJA NILAI EFIKASI DAN FAKTOR DAYA INISIAL LAMPU LED BULB SWABALAST MENGGUNAKAN STANDAR IEC/PAS 62612:2009; ANALYSIS OF PERFORMANCE TESTING OF INITIAL EFFICACY VALUE AND POWER FACTOR OF BULB SELF-BALLASTED LAMP BY USING STANDARD IEC/PAS 62612:2009

Anggono, Tri (Unknown)
Pasaribu, M Irsan (Unknown)
Sasnofia, Weltis (Unknown)
Ahadi, Khalif (Unknown)



Article Info

Publish Date
13 Jul 2016

Abstract

Perkembangan teknologi sistem penerangan buatan memungkinkan adanya peningkatan penghematan pemakaian energi listrik serta umur pakai yang lebih lama. Namun demikian, tingkat efisiensi serta kualitas dari suatu produk tentunya harus melewati pengujian menggunakan metoda standar yang telah disepakati. Penelitian ini bertujuan untuk dapat memberikan gambaran kualitas awal lampu LED bulb yang beredar di Indonesia. Penelitian ini dilakukan dengan menggunakan metoda standar uji IEC/PAS 62612 : 2009. Sampel uji didapat melalui survei pasar di wilayah Jakarta dan sekitarnya dengan daya pengenal antara 2 sampai 13 watt. Pengujian dilakukan menggunakan Integrating Sphere Photometer (ISP) dan Goniophotometer. Analisis terhadap efikasi dan faktor daya lampu LED bulb tersebut dilakukan dengan pendekatan grafik distribusi normal. Sebanyak 30% dari sampel yang diuji menunjukkan adanya ketidaksesuaian daya nyata sebesar ±15% dari daya pengenal pada kemasan. Sebanyak 90% dari populasi sampel menunjukkan nilai efikasi inisial lebih dari 58 lm/w, setara dengan kriteria tanda hemat energi bintang empat lampu fluorescent swabalast dan dapat meningkatkan efisiensi pencahayaan sekitar 29%. Namun demikian, hanya sebesar 3,41% dari sampel yang diuji menunjukkan nilai faktor daya di atas 0,76 sehingga berpotensi dapat mengganggu kinerja jaringan distribusi listrik. The development of artificial lighting system technology enables improvement of electrical energy efficiency and also service life. Nevertheless, efficiency level and product quality surely have to pass the test of agreed standard method. This study aims to provide an overview of initial quality of LED light bulbs which have been marketed in Indonesia. The study is conducted by using a standard test method, IEC / PAS 62612: 2009. Test samples are obtained through a market survey in Jakarta and its surrounding areas with rated power between 2 into 13 watts. Integrating Sphere Photometer (ISP) and Goniophotometer are used for the testing. Analysis of efficacy and power factor of LED light bulb is done with a normal distribution graph approach. 30 % of total samples tested have ± 15 % deviation between real powers measured and rated power stated on their packaging. 90 % of the sample population is concluded to have initial efficacy value higher than 58 lm / w; equivalent to the four stars of energy-saving criteria for fluorescent self-ballasted lamp, and these lamps can improve the lighting efficiency approximately 29 %. However, only 3.41 % of the tested samples have power factor values above 0.76 that it may potentially affect electrical distribution line.

Copyrights © 2014






Journal Info

Abbrev

ket

Publisher

Subject

Electrical & Electronics Engineering Energy

Description

Ketenagalistrikan dan Energi Terbarukan merupakan jurnal ilmiah yang berisi hasil penelitian/kajian dibidang ketenagalistrikan, energi baru, terbarukan, dan konservasi energi. Diterbitkan melalui proses review oleh Pusat Penelitian dan Pengembangan Teknologi Ketenagalistrikan, Energi Baru, ...