Jurnal Imejing Diagnostik
Vol 5, No 1: January 2019

RADIATION DOSE REDUCTION ON BREAST AREA BY USING LEAD APRON: A PRE-EXPERIMENTAL STUDY IN ABDOMINAL CT

Akhmad Haris Sulistiyadi (Poltekkes Kemenkes Semarang, Indonesia)
Susi Tri Isnoviasih (Poltekkes Kemenkes Semarang, Indonesia)
Dartini Dartini (Poltekkes Kemenkes Semarang, Indonesia)
Eri Hiswara (Pusat Teknologi Keselamatan Radiasi dan Metrologi, Badan Energi Nuklir Nasional Indonesia)



Article Info

Publish Date
31 Jan 2019

Abstract

Backgroud: Previous researches show that the use of out of plane shielding can reduce the radiation dose received by radiosensitive organs around the scan area on CT scan. There is a special shielding designed for CT scans, but currently the type of shielding available in almost all radiology installations is the lead apron. This study aims to determine the dose received by the breast area on CT abdominal scan without shielding and its reduction by giving lead apron shielding on 1800 and 3600.Methods:This is quantitative research with a pre-experimental design. Abdominal CT scan was performed on a whole body CT phantom whose characteristics are close to human body tissue. The radiation dose received by the breast area was measured by Termoluminisence-dosemeter (TLD). TLD’s were placedon the same points. Scanning was performed using Siemens Somaris/5 Syngo, repeated in three conditions: without shielding, lead apron shielded (equivalent to 5 mm Pb) by 1800 and 3600. The rouitne protocol was used (120 kv and 200 mA) Data was analyzed by Paired t-test to determine the difference in radiation dose received and descriptive analysis for know the level of reduction.Results:The radiation dose received by the breast area without shielding, with shielding 1800, and with shielding 3600 were respectively 0.653 mSv, 0.367 mSv, and 0.242 mSv. There were significant differences in the dose received by the breast area (p value 0.05) by using shielding. Compared to unshieldied condition, there was a decrease of 43.95% when shielded 1800, and a decrease of 62.94% when shielded 1800.Conclusion:Lead apron is effective for reducing radiation dose on breast in abdominal CT. 3600 shielding provides higher reduction than 3600 shielding, so it can be considered to be applied in clinical procedure.

Copyrights © 2019






Journal Info

Abbrev

jimed

Publisher

Subject

Health Professions Medicine & Pharmacology

Description

Jurnal Imejing Diagnostik (JImeD) memuat tulisan ilmiah dalam bidang radiologi berupa hasil penelitian dan non penelitian (konseptual). Jurnal Imejing Diagnostik (JImeD) terbit 2 kali dalam satu tahun yaitu pada bulan Januari dan Juli oleh Jurusan Teknik Radiodiagnostik dan Radioterapi, Politeknik ...