cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
agus.syifa85@gmail.com
Editorial Address
Jl . Garuda No. 09 Tambakberas Jombang East Java
Location
Kab. jombang,
Jawa timur
INDONESIA
Jurnal Sains Dan Teknologi (SAINTEKBU)
JURNAL SAINTEKBU adalah Jurnal ilmiah yang mewadahi hasil penelitian bidang informatika, ilmu komputer, teknologi komputer yang diterbitkan oleh Universitas KH. A. Wahab Hasbullah (UNWAHA)
Articles 1 Documents
Search results for , issue "Vol 12 No 1 (2020): Volume 12 No 1 Tahun 2020 (On Process )" : 1 Documents clear
IDENTIFIKASI RETINA MENGGUNAKAN ALIHRAGAM GELOMBANG SINGKAT Wijayanti, Aris
SAINTEKBU Vol 12 No 1 (2020): Volume 12 No 1 Tahun 2020 (On Process )
Publisher : KH.A.Wahab Hasbullah University

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (248.074 KB) | DOI: 10.32764/saintekbu.v12i1.852

Abstract

Identification of a retinal biometric identification method with a low error rate due to the unique patterns in the retina of blood vessels behind the retina. These patterns can be used as training data for the recognition system is then used for comparison when the identification is done. This study aims to identify the image of the human eye retina, either the left or right side, using image processing techniques and measuring the normalized Euclidean distance. So far, research on biometric systems, particularly with the object of the eye's retina, the eye is done at the owner from the owner's eyes with diverse backgrounds, such as the Messidor database. In this study created a system that can recognize the retinal image using the transformation Haar short waves by measuring the normalized Euclidean distance. The retinal image will be the initial pretreatment process of changing the original image into a grey image, which is then performed using the Haar wavelet feature extraction to obtain the energy that will be used for the normalization of the Euclidean distance so that the process of recognition by Euclidean values ??are compared. Testing is done using eye retinal image database taken from Messidor many as 100 of the 300 images taken at random were then stored in a database, the database is one of 100 images stored, the database of 100 images stored 2, and 3 as many as 100 images database stored. Of the best database testing should be done as much as 6 levels of decomposition levels. From the test results have identified the recognition accuracy rate of up to 98%. The greatest degree of familiarity is level 1 that is equal to 98%. Followed usage by 80% level 2, level 3 is 59%, level 4 is 47%, level 5 is 45% and the lowest is the last level 6 that is equal to 37%.

Page 1 of 1 | Total Record : 1