cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kota adm. jakarta timur,
Dki jakarta
INDONESIA
Spektra: Jurnal Fisika dan Aplikasinya
ISSN : 25413384     EISSN : 25413392     DOI : -
Arjuna Subject : -
Articles 1 Documents
Search results for , issue "Vol. 5 No. 1 (2020): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 5 Issue 1, April 2020" : 1 Documents clear
ANALYSIS OF THE EFFECT OF CARE DOSE 4D SOFTWARE USE ON IMAGE QUALITY AND RADIATION DOSE ON THE CT SCAN ABDOMEN Kartika Sari, Ni Larasati; Suzana, Merry; Muslim, Muzilman; Muliyati, Dewi
Spektra: Jurnal Fisika dan Aplikasinya Vol. 5 No. 1 (2020): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 5 Issue 1, April 2020
Publisher : Program Studi Fisika Universitas Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (314.613 KB) | DOI: 10.21009/SPEKTRA.051.04

Abstract

The CT Scan is the most significant contributor to radiation dose on radiological examination, although the frequency of the examination is far below other modalities. In order to control this radiation dose, manufactures of CT Scan have equipped their units with built-in software called Automatic Exposure Control (AEC). This study aims to analyze the effect of AEC software, CARE Dose 4D, on image quality, and CTDIvol. Objects used in this study were three water phantoms, each with a diameter of 165 mm, 230 mm, and 305 mm. The image quality-analyzed was CT Number and noise. Measurement of image quality was carried out following Bapeten's provisions. Noise Power Spectrum (NPS) graphics were also used to further observes noise texture. The CT Number accuracy, CT Number, and noise uniformity obtained with and without CARE Dose 4D, on the three phantoms were still within Bapeten's threshold. This indicates that the use of CARE Dose 4D can still image a homogeneous object accurately. The results of the NPS curve showed that the two modes, in three phantoms, were having the same noise texture. The NPS curves also showed that the use of CARE Dose 4D produces higher noise than the non-CARE Dose 4D mode. Meanwhile, there were significant differences from the CTDIvol obtained from the two modes. The use of CARE Dose 4D software reduced dose of up to 54.34%. From this, the use of CARE Dose 4D software can reduce the radiation dose while maintaining image quality.

Page 1 of 1 | Total Record : 1


Filter by Year

2020 2020


Filter By Issues
All Issue Vol. 10 No. 3 (2025): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 10 Issue 3, December 2025 Vol. 10 No. 2 (2025): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 10 Issue 2, August 2025 Vol. 10 No. 1 (2025): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 10 Issue 1, April 2025 Vol. 9 No. 3 (2024): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 9 Issue 3, December 2024 Vol. 9 No. 2 (2024): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 9 Issue 2, August 2024 Vol 9 No 2 (2024): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 9 Issue 2, August 2024 Vol. 9 No. 1 (2024): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 9 Issue 1, April 2024 Vol. 8 No. 3 (2023): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 8 Issue 3, December 2023 Vol. 8 No. 2 (2023): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 8 Issue 2, August 2023 Vol. 8 No. 1 (2023): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 8 Issue 1, April 2023 Vol. 7 No. 3 (2022): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 7 Issue 3, December 2022 Vol 7 No 3 (2022): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 7 Issue 3, December 2022 Vol 7 No 2 (2022): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 7 Issue 2, September 2022 Vol 7 No 1 (2022): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 7 Issue 1, April 2022 Vol. 6 No. 3 (2021): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 6 Issue 3, December 2021 Vol 6 No 3 (2021): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 6 Issue 3, December 2021 Vol 6 No 2 (2021): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 6 Issue 2, October 2021 Vol 6 No 1 (2021): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 6 Issue 1, April 2021 Vol 5 No 3 (2020): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 5 Issue 3, December 2020 Vol 5 No 2 (2020): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 5 Issue 2, August 2020 Vol 5 No 1 (2020): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 5 Issue 1, April 2020 Vol. 5 No. 1 (2020): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 5 Issue 1, April 2020 Vol 4 No 3 (2019): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 4 Issue 3, December 2019 Vol 4 No 2 (2019): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 4 Issue 2, August 2019 Vol 4 No 1 (2019): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 4 Issue 1, April 2019 Vol 3 No 3 (2018): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 3 Issue 3, December 2018 Vol 3 No 2 (2018): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 3 Issue 2, August 2018 Vol 3 No 1 (2018): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 3 Issue 1, April 2018 Vol 2 No 3 (2017): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 2 Nomor 3, Desember 2017 Vol 2 No 2 (2017): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 2 Nomor 2, Agustus 2017 Vol 2 No 1 (2017): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 2 Nomor 1, April 2017 Vol 1 No 2 (2016): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 1 Nomor 2, Desember 2016 Vol 1 No 1 (2016): SPEKTRA: Jurnal Fisika dan Aplikasinya, Volume 1 Nomor 1, Agustus 2016 More Issue