cover
Contact Name
Dayat Kurniawan
Contact Email
Dayat Kurniawan
Phone
-
Journal Mail Official
redaksi@jurnalet.com
Editorial Address
-
Location
Kota adm. jakarta selatan,
Dki jakarta
INDONESIA
Jurnal Elektronika dan Telekomunikasi
ISSN : 14118289     EISSN : 25279955     DOI : -
Core Subject : Engineering,
Jurnal Elektronika dan Telekomunikasi (JET) is an open access, a peer-reviewed journal published by Research Center for Electronics and Telecommunication - Indonesian Institute of Sciences. We publish original research papers, review articles and case studies on the latest research and developments in the field of electronics, telecommunications, and microelectronics engineering. JET is published twice a year and uses double-blind peer review. It was first published in 2001.
Arjuna Subject : -
Articles 15 Documents
Search results for , issue "Vol 25, No 2 (2025)" : 15 Documents clear
Preface Vol. 25 No. 2 Prini, Salita Ulitia
Jurnal Elektronika dan Telekomunikasi Vol 25, No 2 (2025)
Publisher : National Research and Innovation Agency

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55981/jet.834

Abstract

Fabrication of Quartz Crystal Microbalance Coated with GO/PVC Nanofiber for Benzene Detection as Tuberculosis Biomarker Nugroho, Doni Bowo; Kamal, Nada Nadzira Ayasha; Wati, Rosita; Resfita, Nova
Jurnal Elektronika dan Telekomunikasi Vol 25, No 2 (2025)
Publisher : National Research and Innovation Agency

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55981/jet.765

Abstract

Tuberculosis (TB) is a highly contagious illness and a major contributor to global mortality, with over 1.5 million deaths reported annually. TB is caused by Mycobacterium tuberculosis (Mtb), which is often difficult to diagnose in the early stages of infection. Existing diagnostic methods are limited by long processing times, high costs, and suboptimal sensitivity. Therefore, this study aimed to develop a Quartz Crystal Microbalance (QCM)-based biosensor employing polyvinyl chloride (PVC) nanofibers coated with graphene oxide (GO) for rapid detection of volatile TB biomarkers, particularly benzene. The sensing platform utilized a 10 MHz AT-cut silver electrode QCM coated with electrospun PVC nanofibers, followed by GO deposition via immersion. Scanning Electron Microscopy (SEM) showed uniform nanofibers with diameters increasing from 183 ± 54 nm to 348 ± 50 nm after GO coating, while FTIR confirmed the presence of GO functional groups. Sensor evaluation revealed a clear and concentration-dependent frequency shift, with a sensitivity of 1.88 Hz·L/mg, a strong linear correlation (R² = 0.99) across 1.18–23.68 mg/L, and a fast response time of 71 seconds. The limits of detection and quantification were determined to be 0.88 mg/L and 2.66 mg/L, respectively. Adsorption followed the Langmuir isotherm model, indicating monolayer uptake. These results demonstrate that the GO/PVC nanofiber-coated QCM offers a promising, low-cost, and sensitive approach for TB biomarker detection in breath analysis.
PID Controller-Based Closed-Loop Fast Charging of Lithium-Ion Batteries Using the CCCV Method Sutikno, Tole; Wahono, Tri; Baswara, Ahmad Raditya Cahya
Jurnal Elektronika dan Telekomunikasi Vol 25, No 2 (2025)
Publisher : National Research and Innovation Agency

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55981/jet.749

Abstract

This paper presents a closed-loop fast charging system for lithium-ion batteries based on the Constant-CurrentConstant-Voltage (CCCV) method enhanced with a ProportionalIntegralDerivative (PID) controller. The proposed system dynamically regulates the charging parameters by using real-time feedback from voltage and current sensors, with the aim of improving the efficiency of the charging and ensuring battery safety. Experimental results demonstrate that the PID-controlled method maintains a higher current during the initial bulk charging phase, significantly reduces total charging time, and avoids harmful voltage overshoot. Compared to conventional CCCV charging, the system achieves more stable voltage regulation and gradual current tapering, effectively minimizing thermal stress and preventing overcharging. A comparative analysis shows that the PID approach outperforms traditional methods in terms of energy efficiency, thermal management, and operational safety. The system architecture is suitable for integration into Battery Management Systems (BMS) of electric vehicles, portable electronics, and renewable energy storage. This research not only validates the practicality of using PID in fast charging applications but also lays the foundation for future enhancements using intelligent control strategies and adaptive learning algorithms. The findings suggest that PID-controlled charging systems offer a promising solution to the challenges of rapid, reliable, and safe energy replenishment in modern battery-powered technologies.
Back Cover Vol. 25 No. 2 Prini, Salita Ulitia
Jurnal Elektronika dan Telekomunikasi Vol 25, No 2 (2025)
Publisher : National Research and Innovation Agency

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55981/jet.836

Abstract

Smartphone-Based Colorimetric Platform with RGB-CIELAB Multivariate Regression and 3D-Printed Illumination for Portable Multi-Analyte Detection Manurung, Robeth Viktoria; Telaumbanua, Jonathan Edwards; Lim, Richard Anthony; Astuti, Winda; Mada, Dedi; Andreani, Agustina Sus
Jurnal Elektronika dan Telekomunikasi Vol 25, No 2 (2025)
Publisher : National Research and Innovation Agency

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55981/jet.798

Abstract

Smartphone-based colorimetry has become a promising alternative to bulky and expensive spectrophotometers for portable and field analysis. This study aims to develop Colorizer, a modular smartphone-based colorimetric platform that provides accurate and affordable measurements for environmental, chemical, and biomedical applications. The system combines a custom Android app with a 3D-printed sampling station featuring controlled LED illumination, RGB-to-CIELAB conversion, calibration blanking, and multivariate regression modeling to ensure consistent measurements across devices. Illumination is controlled by an ESP32 microcontroller and activated via Bluetooth inside a light-tight chamber to minimize ambient interference. Validation experiments with synthetic dye assays showed strong agreement for red and yellow standards (R² = 0.944 and 0.940, RMSE = 6.503 and 6.955) and lower accuracy for blue assays (R² = 0.868, RMSE = 10.423), likely due to reduced signal-to-noise ratio at higher absorbance. These findings confirm that the platform delivers reliable and portable performance while functioning fully offline with locally stored calibration data. The study suggests that Colorizer offers a practical, low-cost alternative to benchtop spectrophotometers, with future work to validate its use with real-world analytes such as water contaminants, food safety markers, and clinical biomarkers.

Page 2 of 2 | Total Record : 15