ISSN : 22528792     EISSN : 27222624     DOI : -
Core Subject : Engineering,
International Journal of Applied Power Engineering (IJAPE) focuses on the applied works in the areas of power generation, transmission and distribution, sustainable energy, applications of power control in large power systems, etc. The main objective of IJAPE is to bring out the latest practices in research in the above mentioned areas for efficient and cost effective operations of power systems. The journal covers, but not limited to, the following scope: electric power generation, transmission and distribution, energy conversion, electrical machinery, sustainable energy, insulation, solar energy, high-power semiconductors, power quality, power economic, FACTS, renewable energy, electromagnetic compatibility, electrical engineering materials, high voltage insulation technologies, high voltage apparatuses, lightning, protection system, power system analysis, SCADA, and electrical measurements.
Arjuna Subject : -
Articles 8 Documents
Search results for , issue "Vol 3, No 2: August 2014" : 8 Documents clear
Hybrid Generation Power System for Domestic Applications Qazi Waqar Ali; Muhammad Aamir; Arshad Nawaz; Zaki Udin; Shahid Ullah
International Journal of Applied Power Engineering (IJAPE) Vol 3, No 2: August 2014
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (470.288 KB) | DOI: 10.11591/ijape.v3.i2.pp82-89

Abstract

This work presents the plan and model of the control strategy for the interconnection of the hybrid energy system able to regulating this load’s voltage and controlling the energy generation with the energy options. The control strategy contains controlling the energy generated through each energy source, in a hierarchical mode using sliding/dropping mode control, while consuming consideration elements that have an impact on each electrical power source and transform the energy generated in order to suitable circumstances for lower power and domestic programs. The cross alternative energy system consists of photovoltaic cellular material, fuel cellular material and battery packs. A numerical equation in order to estimate the perfect voltage involving photovoltaic systems for virtually every solar irradiance and temperature circumstances is suggested. Simulations of a single or a lot more systems interconnected towards the load with the entire proposed control scheme, under different ecological and weight conditions, usually are introduced to indicate this efficiency with the procedure.
Modeling and Simulation of SVPWM Based Application Ashish Porwal; Ketan Baria; Anuradha Deshpande
International Journal of Applied Power Engineering (IJAPE) Vol 3, No 2: August 2014
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1221.17 KB) | DOI: 10.11591/ijape.v3.i2.pp140-148

Abstract

Recent developments in power electronics and semiconductor technology have lead to widespread use of power electronic converters in the power electronic systems. A number of Pulse width modulation (PWM) schemes are used to obtain variable voltage and frequency supply from a three-phase voltage source inverter. Among the different PWM techniques proposed for voltage fed inverters, the sinusoidal PWM technique has been popularly accepted. But there is an increasing trend of using space vector PWM (SVPWM) because of their easier digital realization, reduced harmonics, reduced switching losses and better dc bus utilization. This project focuses on step by step development of SVPWM technique. Simulation results are obtained using MATLAB/Simulink software for effectiveness of the study.
Towards An Accurate Modeling of Frequency-dependent Wind Farm Components Under Transient Conditions M. A. Abd-Allah; Mahmoud N. Ali; A. Said
International Journal of Applied Power Engineering (IJAPE) Vol 3, No 2: August 2014
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (823.857 KB) | DOI: 10.11591/ijape.v3.i2.pp90-104

Abstract

Frequency dependence complete model is set up for describing the lightning transient behavior of the wind turbines (WTs).To get an appropriate wind turbine model, a high frequency models of surge arrester protecting the boost transformer, transformer and ground electrode soil ionization are implemented. The transient responses and Ground Potential Rise (GPR) can be obtained at different locations in the WTs and connected grid in the time domain as well as in the frequency domain using Fast Fourier Transform (FFT). To check the validity of the model, Surge arresters protection level at different locations, at i.e. LV, MV and HV, is compared with ABB manufacture data sheet, Also a comparison has been made between simple and frequency dependence model of overall wind farm components using ATP/EMTP. This paper provides an accurate simulation of wind farm components under transient condition.
Ash Cooler Heat Recovery Under Energy Conservation Scheme Vikash R Gupta; Lalatendu Pattanayak
International Journal of Applied Power Engineering (IJAPE) Vol 3, No 2: August 2014
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (690.347 KB) | DOI: 10.11591/ijape.v3.i2.pp105-114

Abstract

A healthy fluidization state in circulating fluidized-bed combustion (CFBC) combustor is attributed to proper quantity of hot bed material (ash), which acts as a thermal fly-wheel. It receives & stores thermal energy from the burning of fuel (lignite) & distributes uniformly throughout the combustor & helps in maintaining a sustained combustion. The quantity of bed ash inside the combustor or size of the bed, depends upon boiler load & subsequently upon combustor temperature, lignite feed rate and ash % in lignite. As these parameters varies during process continuously, sometimes it becomes necessary to drain out the ash from the combustor. As & when differential pressure across the bed is increased from a justified level, draining of hot bed ash starts into Ash Coolers. Bed ash is drained at very high temperature of 850 oC & it also contains burning particles of lignite. This paper describes the heat recovery from bed ash, unloaded from the combustor into ash cooler, by pre-heating the condensate water of turbine cycle in a 125 MW CFB boiler of Surat Lignite Power Plant in India. The thermal performance of ash cooler was derived by doing a heat balance calculation based on the measured temperature of ash and cooling water with different load. From the heat balance calculation influence of ash temperature and ash amount on heat transfer coefficient is determined. Simulation is carried out around main turbine cycle indicates improved thermal economy of the unit, higher plant thermal efficiency, lower plant heat rate and reduce fuel consumption rate. Also simulation result shows that the heat transfer coefficient increase with ash amount and decreases with increase in ash temperature.
Assessment of Electric Field Distribution Inside 500/220 kV Open Distribution Substations During Working Conditions Sayed A. Ward; Samy M. Ghania; Essam M. Shaalan
International Journal of Applied Power Engineering (IJAPE) Vol 3, No 2: August 2014
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (967.942 KB) | DOI: 10.11591/ijape.v3.i2.pp115-123

Abstract

The high level electric field intensity produced by high voltage (HV) equipments inside 500/220 kV substations is harmful for the human (staff) health. Therefore the minimum health and safety requirements regarding the exposure of workers to the risk arising from electric fields produced inside these substations is still considered as a competitive topic for utility designers, world health organization (WHO) and biomedical field researchers. It is very important to have knowledge about levels distribution of electric field intensity within these high voltage substations as early stage in the process of substation design. This paper presents results of investigation 50Hz electric field intensity distribution inside 500/220 kV power transmission substations in Cairo, Egypt. This paper presents a method for assessment the distribution of 50HZ electric field intensity distribution inside this substation, this method of analysis is based on the charge simulation technique (CSM). This study will serve for planning service works or for inspection of equipment on HV power transmission substations.
Influence of Static VAR Compensator for Undervoltage Load Shedding to Avoid Voltage Instability Reshma Rajan; Venkateswara Rao; G. V. Nagesh Kumar
International Journal of Applied Power Engineering (IJAPE) Vol 3, No 2: August 2014
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (468.604 KB) | DOI: 10.11591/ijape.v3.i2.pp124-129

Abstract

In the recent years, operation of power systems at lower stability margins has increased the importance of system protection methods that protect the system stability against various disturbances. Among these methods, the load shedding serves as an effective and last-resort tool to prevent system frequency/voltage instability. The analysis of recent blackouts suggests that voltage collapse and voltage-related problems are also important concerns in maintaining system stability. For this reason, voltage also needs to be taken into account in load shedding schemes. This paper considers both parameters in designing a load shedding scheme to determine the amount of load to be shed and its appropriate location .The amount of load to be shed from each bus is decided using the fixed step size method and it’s location has been identified by using voltage collapse proximity index method.  SVC is shunt connected FACTS device used to improve the voltage profile of the system. In this paper impact of SVC on load shedding for IEEE 14 bus system has been presented and analyzed.
Implementation of Hybrid Generation Power System in Pakistan Qazi Waqar Ali; Muhammad Aamir; Arshad Nawaz; Zaki Udin; Shahid Ullah
International Journal of Applied Power Engineering (IJAPE) Vol 3, No 2: August 2014
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (207.261 KB) | DOI: 10.11591/ijape.v3.i2.pp75-81

Abstract

A solar-wind hybrid power generation system has been presented here. The application based system illustrated in this paper is designed on the basis of the solar and wind data for Pakistan. The power generated by the system is intended for domestic use. The most common source of unconventional power in homes is battery based UPS (Uninterrupted power supply) inverter. The UPS inverter charges the battery with conventional grid power. This system will charge the battery of UPS inverter by using only wind and solar power, which will make the system cost effective and more reliable. The reason for using both solar and wind is that recent studies have proven that combined system can be more productive and consistent and other thing is that neither of them can be used for continuous power generation. In the system illustrated in this paper the solar-wind system provides power periodically which is controlled by electronic methods and a microcontroller is used to monitor the power from both the inputs. The switching action is provided from the microcontroller to the battery charging based on the power received from solar photovoltaic panel and wind generators. In this paper, an efficient system has been presented comprising of solar panel, wind generator, charge controller and charge storage unit (battery). Solar panel is selected as the main input and the wind resource will be used only in the absence of the solar photovoltaic (PV) output.
Comparison of FACTS Devices for Two Area Power System Stability Enhancement using MATLAB Modelling J. N. Rai; Naimul Hasan; B. B. Arora
International Journal of Applied Power Engineering (IJAPE) Vol 3, No 2: August 2014
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (524.378 KB) | DOI: 10.11591/ijape.v3.i2.pp130-139

Abstract

Modern Power Transmission networks are becoming increasingly stressed due to growing demand and restrictions on building new lines. Losing stability is one of the major threat of such a stressed system following a disturbance. Flexible ac transmission system (FACTS) devices are found to be very effective in a transmission network for better utilization of its existing facilities without sacrificing the desired stability margin. The static synchronous compensator (STATCOM) and Static Var Compensator (SVC) are the shunt devices of the flexible AC transmission systems (FACTS) family. When system voltage is low, STATCOM generates reactive power and when system voltage is high it absorbs reactive power whereas the Static Var compensator provides the fast acting dynamic compensation in case of severe faults. In this Paper, the performance of SVC is compared with the performance of STATCOM. Proposed controllers are implemented using MATLAB/SIMULINK. Simulation results indicate that the STATCOM controller installed with two machine systems provides better damping characteristics in rotor angle as compared to two machine system installed with SVC. Thus, transient stability enhancement of the two machine system installed with STATCOM is better than that installed with SVC.

Page 1 of 1 | Total Record : 8