cover
Contact Name
Machrus Ali
Contact Email
lppm.undar1965@gmail.com
Phone
+6285728888489
Journal Mail Official
jurnal.jeetech@gmail.com
Editorial Address
Jl. Gus Dur No.29A, Mojongapitindah, Mojongapit, Kec. Jombang, Kabupaten Jombang, Jawa Timur 61419
Location
Kab. jombang,
Jawa timur
INDONESIA
Jurnal JEETech
Published by Universitas Darul Ulum
ISSN : 29647320     EISSN : 27225321     DOI : https://doi.org/10.32492/jeetech.v6i1
Jurnal JEETech: Journal Of Electrical Engineering And Technology. Electrical Engineering. Journal of Darul Ulum University Jombang in collaboration with the Faculty of Engineering, Darul Ulum University Jombang with the Indonesian Electrical Engineering Higher Education Forum (FORTEI). Region VII. East Java. This journal contains research results in the fields of Power Engineering, Telecommunication Engineering, Computer Engineering, Control and Computer Systems, Electronics, Information Technology, Informatics, Data and Software Engineering, Biomedical Engineering. All submitted articles must report original, previously unpublished, experimental or theoretical research results that are not published and are being considered for publication elsewhere. Submissions must be made online through the JEETech submission site. Published twice a year in May and November p-ISSN: 2964-7320 (Print); e-ISSN: 2722-5321 (Online)
Articles 9 Documents
Search results for , issue "Vol. 5 No. 2 (2024): Nomor 2 November" : 9 Documents clear
Implementasi Metode Artificial Bee Colony Untuk Penempatan Distributed Generator Pada Penyulang Rayon Tanjung Hidayat, Rahmat; Lomi, Abraham; Budi Sulistiawati, Irrine
Jurnal JEETech Vol. 5 No. 2 (2024): Nomor 2 November
Publisher : Universitas Darul Ulum

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32492/jeetech.v5i2.5202

Abstract

Distributed Generation (DG) is a power plant that is spread over the power distribution network. In principle, electrical power output is generated by power plants located far from the load center and electrical power is transmitted to the load center through transmission and distribution networks. The longer the cable from the power plant or substation, the lower the voltage at the end load. Sub-optimal DG placement and size can result in increased power losses and affect the system voltage profile. In addition, suboptimal generation capacity can lead to voltage instability, reduced system security, and potential impacts on system frequency and emissions. Therefore, this study will use the Artificial Bee Colony (ABC) method to determine the optimal DG capacity and location. In the base case condition, the power losses in the system are 118 KW and 99 Kvar. Power losses after the installation of 1 DG active power loss becomes 37.4 KW and reactive power loss becomes 31.65 Kvar. Placement of 2 DGs reduces active power loss to 17 KW and reactive power loss to 15 Kvar. While the placement of 3 DG reduces active power loss to 33 KW and reactive power loss to 28 KVar.
Perancangan Time Synchronization Sebagai Alat Bantu Pengujian Intertrip Relay Distance Wicaksono , Ryan; Jasa Kusumo Haryo, R; Ravi Dwi Santoso , Apriando; Dwi Wibowo, Endrik; Ridho Hanafi, Pembri
Jurnal JEETech Vol. 5 No. 2 (2024): Nomor 2 November
Publisher : Universitas Darul Ulum

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32492/jeetech.v5i2.5206

Abstract

At the company PT. PLN (Persero) ULTG Madiun carried out many tests relay, one of which is intertrip testing relay distance. Intertrip testing relay distance is a test carried out between 2 (two) relay distance conducting bays in main substations that face each other. Intertrip testing relay distance must be done if replacement occursrelay, replacement of teleprotection equipment, changes to protection schemes, and changes to logic circuitsrelay which is related to the send or receive signal from the opposite substation. However, this test requires synchronization between two intertrip test tools relay distance at each substation. In this final project, it will be designed Time Syncronization As A Tool For Intertrip Relay Distance Testing, to make things easier for PT employees. PLN (Persero) ULTG Madiun when synchronizing two intertrip test equipment relay distance. All process control of this tool uses ESP32 Devkit V1. Meanwhile for displaying setting time for testing can be seen on the web assisted by GPS NEO-6M. The results obtained when testing the Dolopo by Ponorogo R and S phase distance intertrip relay were carried out at 12.00.00, experiencing a delay time of 0.0553 seconds when the PMT tripped. Meanwhile, the Dolopo by Ponorogo T phase distance intertrip relay test was carried out on 12.09.00 and experienced a delay of 0.0529 seconds when the PMT tripped. From two intertrip relay distance tests, the trip time delay is no more than 0.1 second.
Metode Pengumpulan Data Debit Air Pada Saluran Distribusi Air PDAM Makassar Berbasis IoT Imran, Andi; Nurul Azizah; Gunawan Zain, Satria; Zulhajji; Ajiatmo, Dwi
Jurnal JEETech Vol. 5 No. 2 (2024): Nomor 2 November
Publisher : Universitas Darul Ulum

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32492/jeetech.v5i2.5201

Abstract

Water is an important resource for human survival as well as various economic sectors. PDAM is responsible for providing water supply to the community. One of the major challenges faced in managing water supply is the problem of water loss or leakage. This research aims to overcome this problem by designing an innovative method to collect water discharge data on the distribution channel of PDAM Makassar using Internet of Things (IoT) technology. This method uses the ESP32-CAM to take images of the water meter on the main pipe and save it to a database. Optical Character Recognition (OCR) technology is used to convert the image into text that can be processed. The test results show that the average error in meter readings is 0.215% with an average accuracy rate of 98%. Overall the system works well in reading digital meters and is reliable in monitoring water consumption visually and in real-time. Thus, this method can be an effective solution in detecting water leaks and improving the efficiency of water supply management by PDAMs, as well as saving resources and operational costs.
Pengaruh Penambahan Transformator Sisip pada Trafo Distribusi 200 kVA Kayu Merah Kabupaten Fakfak Yulianto La Elo; Lembang, Naomi; Tianotak, Siti
Jurnal JEETech Vol. 5 No. 2 (2024): Nomor 2 November
Publisher : Universitas Darul Ulum

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32492/jeetech.v5i2.5203

Abstract

Permasalahan ketenagalistrikan di Kabupaten Fakfak bukan hanya terjadi oleh akibat terbatasnya pasokan listrik yang disalurkan oleh PLN, namun juga terjadi akibat proses distribusi listrik ke Masyarakat. Salah satu masalah yang seringkali terjadi adalah presentasi penggunaan tranformator yang telah melebihi dari ketentuan PLN yang mana pembebanan normal transformator adalah 60 % - 80%. Penyulang Danaweria merupakan salah satu penyulang yang seringkali mendapat keluhan dari konsumen Listrik PLN di Kabupaten Fakfak dimana sampai mengakibatkan terjadinya pemadaman listrik oleh PLN. Jika hal ini terus dibiarkan, maka tentu akan mengakibatkan kerusakan pada gardu distribusi yang akan merugikan pihak PLN sebagai penyedia  dan masyarakat sebagai konsumen listrik. Melalui pemasangan transformator sisipan, diharapkan dapat mengurangi beban pada gardu distribusi dengan memindahkan beban ke gardu sisipan. Dalam penelitian ini akan mengkaji terkait pemasangan transformator sisipan untuk mengurangi beban pada gardu distribusi FFK 058, 200kVA Penyulang Danaweria di PT. PLN (Persero) ULP Fakfak, dengan memindahkan sebagian beban ke transformator sisipan 100 kVA. Setelah pemasangan trafo sisipan, beban puncak siang hari dari trafo FFK 058, 200 kVA diperoleh presentase pembebanan sebesar 35,4% dari sebelumnya sebesar 61,07%. Sedangkan pada malam hari, presentase pembebanan sebesar 55,7 % dari sebelumnya 98,23%.  Hasil tersebut menunjukan presentasi pembebanan dalam keadaan normal sesuai ketentuan PLN
Frekuensi Gangguan dan Energi Tak Tersalurkan Sebagai Indikator keandalan Sistem Jaringan Tegangan Menengah Rusliadi, Rusliadi; La Elo, Yulianto
Jurnal JEETech Vol. 5 No. 2 (2024): Nomor 2 November
Publisher : Universitas Darul Ulum

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32492/jeetech.v5i2.5208

Abstract

The increasing need for electrical energy must be balanced with improved customer service. Customers will feel comfortable if they can enjoy an uninterrupted electricity supply in the form of a disconnection of the electricity supply for a certain period of time or what is commonly called the ENS (Energy Not Supplied) index and the AENS (Average Energy Not Supplied) index. The reliability of the electric power system is one of the things that is very important in order to maintain the performance of the three main pillars of PT. PLN (Persero). A reliable distribution network can be seen from the number of disruptions that often occur in the distribution network. Disruptions that arise in the distribution network arise due to internal factors such as less reliable distribution network components. In addition, it can also be caused by external factors such as natural disasters or the influence of trees and animals. Based on the results of the research that has been conducted, it is known that the occurrence of disruptions and the length of the duration of the disruption cause the Energy Not Supplied (ENS) value to increase as in April and July, the high duration of the blackout also makes the ENS higher, namely 792.857804 kW and 789.046811 kW. However, the distribution network at the Wagom feeder is still considered reliable in distributing electrical energy based on the SAIDI and SAIFI indices. From the research results, the SAIDI index at the Wagom feeder reached 8.96 hours/customer/year. While the SAIFI index at the Wagom feeder reached 2.08 times/customer/year.
Metode Simple Additive Weighting (SAW) pada Pemilihan Jenis Lampu Penerang Jalan Berbasis Photovoltaic Tijaniyah, Tijaniyah; Pengestu, Teguh
Jurnal JEETech Vol. 5 No. 2 (2024): Nomor 2 November
Publisher : Universitas Darul Ulum

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32492/jeetech.v5i2.5204

Abstract

The simple additive weighting method is a decision support system method for various decision selection problems. Many research topics use the SAW method as a reference method in a decision support system. The street lighting control system is very useful for residents of the village of Karanganyar, Paiton, Probolinggo. This lighting is the main spotlight for residents' activities at the village office. Such as August competitions, routine monthly recitations, competitions to commemorate Isra' Mi'raj and the Prophet's birthday. There are many types of lamps in stores. The criteria for lamps are that they have high light illumination, long-lasting light, large bulb size, so that they can help village residents carry out activities at night. This lamp also uses photovoltaic as an additional source of electrical energy so it can save electricity costs to PLN. The solar panel measures 550 x 360 x 25 mm, 20 volts and has a peak power of 20 watts
Rancang Bangun Pengumpan Shuttlecock Otomatis Ramadhani, Andito; Paramytha, Nina
Jurnal JEETech Vol. 5 No. 2 (2024): Nomor 2 November
Publisher : Universitas Darul Ulum

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32492/jeetech.v5i2.5209

Abstract

Badminton is one of the most popular sports in Indonesia. This sport not only improves health, but also develops physical, mental and strategic skills. Badminton is also one of the sports that makes Indonesia proud in the international arena thanks to the success of Indonesian badminton players in various world championships. To create reliable badminton players, a very strict training program and the best training facilities are needed, one of which is a drill training program in badminton that feeds continuously, this exercise is very effective depending on how long the ball feeder feeds. Therefore, an innovation to help a coach in training his students, especially in drill training, is an automatic shuttlecock feeder that can feed automatically with varied feeds and with a certain speed that has been programmed using a microcontroller, previously this automatic shuttlecock feeder tool has been made by Reza Kurniawan and Jaka Kurniawan. Still, in this research, the author added a security system using two sensors: an RFID sensor and an ultrasonic sensor.
Rancang Bangun Sistem Kendali Otomasi Ketinggian Meja Dan Lampu Belajar Sesuai Ergonomi Dan Kesehatan Pengguna Junianto; Paramytha , Nina; Fitriani, Endah; Ariyadi, Tamsir
Jurnal JEETech Vol. 5 No. 2 (2024): Nomor 2 November
Publisher : Universitas Darul Ulum

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32492/jeetech.v5i2.5207

Abstract

Ergonomic challenges are associated with study tables often ignore the user's optimal dimensions and posture. A comfortable study environment is needed to improve productivity and health. It is necessary to design and implement an automatic control system for the table height and study light intensity, utilizing ultrasonic sensors and Light Dependent Resistors (LDR) to adapt to the user's needs. Previous studies often neglect the integration of adjustable furniture with smart lighting systems, causing discomfort and inefficiency in the study environment. A new method is needed by combining a linear DC motor actuator with an L298N motor driver to facilitate table height adjustment between 70 cm and 80 cm, while using a relay module to control the brightness of the lights based on ambient light conditions. The results show that the developed system significantly improves user comfort and health, demonstrating its effectiveness in various settings, including home and workplace. The results show that ergonomic design when paired with automation, can improve user concentration and productivity. This study contributes to the field of ergonomic design by providing a practical solution that addresses table height and lighting, ultimately promoting a healthier and more efficient study environment.
Pengaruh Penyesuaian Parameter Membership Function pada Sistem Kendali Robot Balancing Berbasis Fuzzy Logic Santoso, Santoso; Balok Hariadi; Ratna Hartayu; Reza Sarwo Widagdo; Wahyu Setyo Pambudi; M Ary Heryanto
Jurnal JEETech Vol. 5 No. 2 (2024): Nomor 2 November
Publisher : Universitas Darul Ulum

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32492/jeetech.v5i2.5205

Abstract

This research develops a balancing robot control system using a fuzzy logic approach, focusing on the adjustment of membership function parameters. The main components of the system include the ESP32 microcontroller, MPU6050 sensor for detecting tilt angle and angular velocity, and L298 motor driver for DC motor actuation. Triangular-shaped membership functions are implemented, and parameters a, b, and c are adjusted through simulation to enhance system performance. Evaluation results indicate an average settling time of 1.2 seconds, a maximum overshoot of 5%, and a steady-state error of less than 2 degrees. This adjustment successfully balances response speed and stability, providing important guidance for developers in designing a more optimal fuzzy logic control system. The research was conducted at the Electrical Engineering Laboratory of 17 August 1945 University (Untag) Surabaya from June to December 2023.

Page 1 of 1 | Total Record : 9