PERHITUNGAN JATUH TEGANGAN DAN SUSUT DAYA SERTA UPAYA PERBAIKAN PENYALURAN DAYA LISTRIK PADA PT. PLN (PERSERO) RAYON SAMBAS ., Ardhi Surya Nopianto
Jurnal Teknik Elektro Universitas Tanjungpura Vol 2, No 1 (2016): Jurnal Mahasiswa Prodi Elektro UNTAN
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (650.029 KB)

Abstract

Abstrak - Profil tegangan dan susut daya diakibatkan oleh rugi-rugi daya di jaringan karena tingginya impedansi jaringan, karakteristik induktif jaringan listrik serta beban induktif yang tersambung pada jaringan. Dalam kenyataannya, adanya susut daya listrik pada penyediaan energi listrik adalah sesuatu yang tidak bisa dihindarkan. Meski demikian susut energi yang terjadi dalam proses penyaluran dan distribusi energi listrik merupakan suatu pemborosan energi apabila tidak dikendalikan secara optimal. Berdasarkan analisis perhitungan persentase jatuh tegangan pada penyulang Galing dan penyulang Kawakan PT. PLN (Persero) Rayon Sambas, pada penyulang Galing persentase jatuh tegangan maksimum terdapat pada bus 43 (GD 229) yaitu sebesar 5,470%, dengan besar tegangan 18,042 KV. Sedangkan pada penyulang Kawakan persentase jatuh tegangan maksimum terdapat pada bus 14 (GD 170) yaitu sebesar 2,107%, dengan besar tegangan 19,5786 KV. Hasil perhitungan setelah divalidasi dengan metode injeksi arus terdapat perbedaan, disebabkan pada penelitian ini merupakan pendekatan perhitungan jatuh tegangan antar saluran dimana rugi-rugi daya pada saluran diabaikan. Total rugi-rugi daya aktif yang terjadi pada penyulang Kawakan sebesar 9,222 KW, dan pada penyulang Galing sebesar 54,880 KW. Salah satu upaya perbaikan penyaluran daya yaitu dengan mengganti luas penampang penghantar pada seksi saluran yang mengalami persentase jatuh tegangan yang melebihi standar yang diijinkan. Dengan mengganti penghantar AAAC 35 mm2 menjadi AAAC 150 mm2 pada beberapa cabang penyulang Galing yang menghasilkan persentase jatuh tegangan yang besar, mengakibatkan tegangan bus atau gardu-gardu penyulang Galing meningkat, serta menurunkan rugi-rugi daya aktif total yang sebelumnya sebesar 54,880 KW menjadi 49,842 KW. Kata kunci : profil tegangan, persentase jatuh tegangan, rugi-rugi daya aktif, upaya perbaikan
EVALUASI RUGI-RUGI JARINGAN YANG DILAYANI OLEH JARINGAN PLTS TERPUSAT SIDING ., Didik Martono
Jurnal Teknik Elektro Universitas Tanjungpura Vol 2, No 1 (2016): Jurnal Mahasiswa Prodi Elektro UNTAN
Publisher : Fakultas Teknik

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Abstrak- Indonesia secara geografis sebagai Negara tropis, melintang garis katulistiwa berpotensi energi surya yang cukup baik. Bagi masyarakat yang tinggal di daerah kabupaten dan pedesaan, penyedian energi listrik merupakan masalah utama. Karena jaringan listrik PLN belum menjangkau pada daerah tersebut. Solusi yang tepat untuk mengatasi ketiadaan energi listrik di daerah tersebut adalah mengubah cahaya matahari yang melimpah menjadi energi listrik menggunakan teknologi  photovoltaic. Sistem penyediaan listrik seperti ini disebut Pembangkit Listrik Tenaga Surya (PLTS). PLTS terpusat 40 KW di Desa Siding Kecamatan Siding Kabupaten Bengkayang merupakan salah satu pembangkit listrik yang mendukung penyedian energi listrik PLN. Analisis rugi-rugi pada jaringan perlu dilakukan sebagai bahan pertimbangan dalam pengembangan sistem distribusi di masa yang akan datang. Dari hasil analsis yang telah dilakukan, diketahui bahwa :  persentase jatuh tegangan terbesar pada fasa R sebesar 3,215% atau 212,93 Volt, fasa S sebesar 2,930% atau 213,55 Volt, dan fasa T sebesar 3,258% atau 212,83 Volt. Dari persentase jatuh tegangan terbesar pada masing-masing fasa, sistem distribusi jaringan tegangan rendah PLTS Siding masih dalam ketentuan SPLN No.72 Tahun 1987, karena masih dibawah toleransi yaitu 4%. Sedangkan total rugi-rugi daya aktif sistem distribusi jaringan tegangan rendah PLTS Siding merupakan penjumlahan dari total rugi-rugi daya aktif pada masing-masing fasa sebesar 596,87 Watt atau sebesar 1,49%. Kata kunci : photovoltaic, PLTS terpusat, persentase jatuh tegangan, rugi-rugi daya aktif
EVALUASI KUALITAS PENERIMAAN SIARAN ANTV DI WILAYAH KABUPATEN KUBU RAYA ., Hadiansyah
Jurnal Teknik Elektro Universitas Tanjungpura Vol 2, No 1 (2016): Jurnal Mahasiswa Prodi Elektro UNTAN
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Stasiun Televisi Swasta PT. Cakrawala Andalas Televisi Pontianak  atau  lebih  dikenal  ANTV Pontianak adalah salah satu pemancar televisi yang terletak di kota Pontianak. Stasiun Televisi ANTV Pontianak terletak pada koordinat 00º 00′ 55.3″ Lintang Selatan, 109º 20′ 145″ Bujur Timur yang beralamat di Jalan Gusti Situ Mahmud No. 8 RT 4 RW  12  Kelurahan  Siantan  Hulu  Kota  Pontianak, Kalimantan Barat. Antena pemancar Stasiun Televisi ANTV Pontianak yang miliki tinggi 65 meter diatas permukaan   tanah,   menggunakan   frekuensi   video 719.250  MHz  dan  frekuensi  audio  724.750  MHz. Daya  pancar  antena  milik  ANTV  Pontianak  ini adalah 1000 watt dengan 1 panel pemancar yang terletak di atas towernya yang mengarah pada arah tenggara. Dengan 1 buah panel diharapkan dapat membuat  siaran yang  jernih baik dari segi gambar maupun suaranya. Hasil perhitungan diperoleh bahwa jarak jangkau maksimum dari antena pemancar Stasiun  ANTV  Pontianak  adalah  35,48  km, sedangkan untuk analisis kualitas penerimaan video dan audio penulis melakukan penelitian uji coba langsung ke masyarakat pengguna televisi yang menggunakan antena yagi sebagai antena penerima sinyal siaran dan melihat secara langsung kualitas video dan audio yang di terima. Setelah melakukan penelitian   dan   uji   coba,   batas   jarak   jangkau maksimum kualitas sangat baik dan baik. Stasiun Televisi ANTV Pontianak meliputi, Arah Tenggara: Jalan Sultan Agung Desa Sungai Raya Kec. Rasau Jaya Kab. Kubu Raya (26,44 km). Arah Timur: Jalan Raya  Ambawang  Desa  Korek  Kec.  Sungai Ambawang Kab. Kubu Raya (24,13 km). Arah Barat Laut: Jalan Raya Jungkat Desa Sungai Nipah Kec. Siantan  Kab.  Mempawah  (21,6  km).  Arah  Barat: Jalan Raya Sungai Kakap Desa Sungai Kakap Kec. Sungai Kakap Kab. Kubu Raya (21 km).   Kata kunci : Pemancar, ANTV Pontianak, Kualitas video dan audio.
PERANCANGAN PERAHU LISTRIK BERTENAGA SURYA DI KOTA PONTIANAK ., Joko Nursanto
Jurnal Teknik Elektro Universitas Tanjungpura Vol 2, No 1 (2016): Jurnal Mahasiswa Prodi Elektro UNTAN
Publisher : Fakultas Teknik

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Power Boats is a means of transportation in an environmentally friendly water using solar systems, which transform the energy of sunlight into electrical energy stored in the battery and later as an energy source to drive an electric boat engines. This electric boats as the development of renewable energy do not use fuel that is increasingly growing number of limited and expensive prices. Electric boats have a speed of 7 km / h and can operate for approximately 11.46 hours. The electric boats using solar panels solar Skytech SIM-100 wp, Trojan 31-GEL battery with a capacity of 102 Ah, Solar Charge Controller Shinyoku SC 990 (12V - 10A) engine powered boat Trolling Motor 0.50 pk made in China. Keywords: Power Boats, PLTS, Renewable Energy.
STUDI POTENSI LIMBAH KOTA SEBAGAI PEMBANGKIT LISTRIK TENAGA SAMPAH (PLTSa) KOTA SINGKAWANG ., URAY IBNU FARUQ
Jurnal Teknik Elektro Universitas Tanjungpura Vol 2, No 1 (2016): Jurnal Mahasiswa Prodi Elektro UNTAN
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Abstract -   Source of electrical energy is currently the main problems in Singkawang city, this is because the number of population density increased annually. Besides, the problem of the amount of waste continues to rise, these two problems can be solved with one  solution  to  convert  a  renewable  energy that makes a potential where trash converted into power plant of waste to energy. To determine whether the waste can be a solution to the energy crisis by conducting a study of potential  waste  or  garbage  into  fuel  power plant. writing this essay described how rubbish can  produce  electrical  energy  for  24833.76 kWh / day if operating for one year amounted to 9,064,322.4 kWh / year or 9064.32 MWh / year, The first step is to know the total amount of  organic  waste  per  day,  the  number  of calories in the organic waste, the amount of energy (kWh) / day, the capacity of power generation, the power output of the boiler, steam turbine net power.   Kata kunci : garbage of potential study, waste to energy, steam of power plant
PERANCANGAN DAN ANALISA CIRCULAR POLARITY ANTENNA CROSSHAIR WAVEGUIDE SEBAGAI PENGUAT WIFI ADAPTER TP-LINK TL-WN723N PADA FREKUENSI 2,4 GHZ ., Yulianus Sandi
Jurnal Teknik Elektro Universitas Tanjungpura Vol 2, No 1 (2016): Jurnal Mahasiswa Prodi Elektro UNTAN
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Abstrak  - Waveguide  Crosshair Antenna   with   reflectors   which   has   the function to change the radiation pattern and beam width antenna beam so that in itself could increase the antenna gain. The amount of  change  in  the  gain  generated  by  the addition of the reflector can be affected by several things, among them is to set the size of the  reflector  panel  angle  (α),  adjust  the amount of spacing between the driven element and reflector panel (space), and change the length dimension of the reflector (h). The resulting radiation pattern     waveguide Crosshair antenna is directional, the signal emitted in two directions with the same magnitude.  With  the  addition  of  reflectors, will limit the radiation pattern from being widened backward and transmits force will be strengthened in the opposite direction, so that one  can  clearly  see  how  it  changes  the transmit antenna patterns before and after the addition  of  the  reflector,  the  antenna amplifier is more devoted to the working frequency of 2.4 GHz for wireless LAN ( local area network ). The parameters that must be considered in designing antennas for wireless LAN is working frequency. To test the speed of the download (download) and upload (upload), conducted through speedtest.net on two different networks, namely network UNTAN hotspot network in the faculty of engineering with download speeds of 72.23 Mbps, 50.56 Mbps upload network and the Faculty  of  Engineering  at  the  speed  3.05 Mbps download, upload 2.13 Mbps, which is influenced by the speed  speedtest maximum value and minimum speed provided by the ISP (internet Service Provider). Kata kunci: Crosshair Waveguide Antenna, External Antenna, Wifi Adapter frekuensi 2.4 GHz
ANALISIS QUALITY OF SERVICE DAN PENERIMAAN SINYAL WIMAX 3.3 GHZ PADA KONDISI LINE OF SIGHT DAN KONDISI NON LINE OF SIGHT PT APLIKANUSA LINTASARTA PONTIANAK ., Rendi Andika
Jurnal Teknik Elektro Universitas Tanjungpura Vol 2, No 1 (2016): Jurnal Mahasiswa Prodi Elektro UNTAN
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Abstract PT. Aplikanusa Lintasarta area Pontianak sebagai penyedia layanan Internet dan jaringan Virtual Private Network(VPN). PT. Lintasarta menyediakan berbagai media akses telekomunikasi data salah satunya menggunakan media akses Broadband Wireless Access (BWA) yang merupakan teknologi WiMAX dimana antena pemancar WiMAX PT. Lintasarta terletak di BTS Arena Remaja milik PT. Indosat Jl. Sukajaya. Kota Pontianak yang merupkan daerah yang berkembang dimana terdapat pembangunan insfratuktur dan gedung – gedung tinggi yang memungkinkan dalam performansi WiMAX yang dipancarkan dari Base Station (BS) ke Subscriber Station (SS) mengalami Non-Line of Sight (NLOS) sehingga pada penelitian akan dilakukan analisis kekuatan sinyal penerimaan WiMAX yang didapatkan dalam percobaan keadaan Line of Sight (LOS) dan Non-Line of Sight (NLOS) atau keadaan terhalang gedung serta menganalisa pengaruh terhadap modulasi dan bandwidthnya.  Permasalahan yang terjadi kualitas penerimaan sinyal WiMAX dalam keadaan LOS dan NLOS (terhalang) oleh gedung serta bagaimana pengaruh terhadap modulasi dan bandwidth yang didapatkan serta parameter QoS adalah delay/latency, Packet Loss, dan throughput. Sedangakan untuk menilai kekuatan sinyal penerima digunakan  Receive Symbol Strengh. Berdasarkan hasil perhitungan, maka dapat disimpulkan nilai kualitas layanan berdasarkan QoS untuk kondisi LOS dan NLOS yaitu : Pada parameter delay dari hasil capture aplikasi WiMAX. Pada kondisi LOS rata-rata sebesar 9,18 ms dan pada kondisi NLOS rata-rata sebsar 14,32 ms. Pada parameter delay dari hasil capture aplikasi WiMAX. Pada kondisi LOS rata-rata sebesar 83,403 % dan pada kondisi NLOS rata-rata sebsar 69,58%. Pada parameter delay dari hasil capture aplikasi WiMAX. Pada parameter Packet Loss kondisi LOS rata-rata sebesar 0% dan pada kondisi NLOS rata-rata sebesar 0%. Kekuatan sinyal penerima untuk kondisi LOS berupa QAM dengan nilai RSSI rata-rata sebesar -64,06 dBm. Kekuatan sinyal penerima untuk kondisi NLOS berupa QAM, QPSK dan BPSK dengan nilai RSSI rata-rata sebesar -83,96 dBm. Kata kunci - Quality of Service, Delay, Jitter, Throughtput, Packet Loss dan Receive Symbol Strengh.
PERAMALAN BEBAN DENGAN MENGGUNAKAN METODE TIME SERIES UNTUK KEBUTUHAN TENAGA LISTRIK DI GARDU INDUK SUNGAI RAYA ., Syarif M. Bahtiar
Jurnal Teknik Elektro Universitas Tanjungpura Vol 2, No 1 (2016): Jurnal Mahasiswa Prodi Elektro UNTAN
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Abstrak- Penelitian ini bertujuan untuk mengetahui besarnya kebutuhan tenaga listrik pada gardu induk sungai raya PLN Kalimantan Barat. Pemilihan gardu induk sungai raya di dasarkan pada nilai rata-rata kenaikan yang paling besar di antara gardu induk yang ada. Dari 2431 A pada tahun 2011 menjadi 2879 A pada 2014. Kenaikan ini di sebabkan dalam kurun waktu 10 tahun ini, pertumbuhan ekonomi di kota Pontianak cukup tinggi, sehingga kebutuhan energi listrik juga akan meningkat. Metode yang di gunakan untuk mengetahui kebutuhan energi pada gardu induk sungai raya ini menggunakan Metode Time Series dengan menggunakan waktu sebagai dasar peramalan, kemudian di olah secara statistik untuk menentukan pola perkiraan di masa yang akan datang. Dari hasil peramalan tersebut dapat digunakan untuk merencanakan pengembanagan  sistem dan peralatan kelistrikan pada PLN Wilayah V Kalimantan Barat.   Kata Kunci : Beban Listrik, Time Series dan Peramalan
PENENTUAN LETAK OPTIMUM ARRESTER PADA GARDU INDUK (GI) 150 kV SIANTAN MENGGUNAKAN METODE OPTIMASI ., Ringga Nurhaidi
Jurnal Teknik Elektro Universitas Tanjungpura Vol 2, No 1 (2016): Jurnal Mahasiswa Prodi Elektro UNTAN
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Substation 150 kV Siantan frequent disturbances from lightning strikes. Where based on the results of the analysis in 2015, the number of lightning strikes in the transmission network is approximately 30 times strike. Therefore, we need a protection device to protect this transmission network. The main protection against lightning strikes on the network transmission is lightning arresters. Where, to selecting a reliable arrester for use, note the value of the identifier / rating of the arrester is appropriate for use on a 150 kV substation Siantan. From this research, the results of the analysis and calculation of the value for the distance Optimum arrester on the transformator (S) at 150 kV substations Siantan using lagrange method is 34,784 meter, while the identifier / rating of the arrester to be used are as follows: identifier arester voltage (UC) = 134.64 kV, the working voltage arrester (Ea) = 414.333 kV, operating current arrester (He) = 5.504 kA, Keywords: lightning arrester (LA), lagrange method, the parent Siantan 150 kV Substation