cover
Contact Name
Furaida Khasanah
Contact Email
ners.fura@gmail.com
Phone
+628989916124
Journal Mail Official
furaida.khasanah@poltekkesjogja.ac.id
Editorial Address
Jl Tata Bumi No 3, Banyuraden Gamping
Location
Kota yogyakarta,
Daerah istimewa yogyakarta
INDONESIA
Jurnal Teknologi Kesehatan
ISSN : 02164981     EISSN : 26139944     DOI : https://doi.org/10.29238/jtk
Core Subject : Health,
Jurnal Teknologi Kesehatan (Journal of Health Technology), with registered number ISSN 0216-4981 (print) and 2613-9944 (online), is a scientific journal published by Poltekkes Kemenkes Yogyakarta. The journal is registered in the CrossRef system with Digital Object Identifier (DOI) prefix 10.29238. Its Journal covers a lot of common problems or issues related to the health sciences. The aim of this journal publication is to disseminate the conceptual thoughts or ideas and research results that have been achieved in the area of health sciences. Jurnal Teknologi Kesehatan (Journal of Health Technology) particularly focuses on the main problems in the development of the sciences of Health sciences areas. It covers the Medical Laboratory Technology area, nursing area, midwifery area, dental nursing area, nutrition area, environmental health, and any sciences that cover the health sciences area.
Articles 11 Documents
Search results for , issue "Vol. 12 No. 2 (2016): September" : 11 Documents clear
Pengaruh Volume, Lama Pendiaman dan Suhu Penyimpanan Darah Pada Pemeriksaan Mikrohematokrit Terhadap Nilai Hematokrit Anik Nuryati; Suhardjono Suhardjono
Jurnal Teknologi Kesehatan (Journal of Health Technology) Vol. 12 No. 2 (2016): September
Publisher : POLTEKKES KEMENKES YOGYAKARTA

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (630.933 KB)

Abstract

Hematocrit is a special blood test to help diagnose a variety of diseases, including Dengue Hemorrhagic Fever (DHF), anemia, and polycythemia. Several obstacles often encountered in the examination, such as blood sampling volume, a delay time of inspection, and storage temperature. This study aims to determine the effect of high-volume variation, the standing time and the storage temperature of blood for hematocrit values. Thus it can provide information for health care workers and laboratory technician to determine a better microhematocrit examination. The type of the research is Quasi-Experiment since there is no randomization. The research was conducted from May to October 2015 in Yogyakarta Regional Health Laboratory and Citra Pratama Laboratory. The subjects were 10 men, aged 20-50 years, healthy (regular blood checks). Venous blood was taken as much as 5 ml and divided into 5 bottles of vials contained EDTA anticoagulant. One bottle was checked immediately; four bottles were stored for 1 and 2 hours at room temperature (16°C) and refrigerator temperature (8°C). The blood was inserted into 3, 4, 5, and 6 cms microhematocrit tube. The tip of the tube was closed by wax and then centrifuged 15,000 rpm for 5 minutes. The number of tightly-packed erythrocytes was read with haematocrit scale. The examination result showed that the hematocrit score was stable at 4 cms blood volume height, and was stored at 8°C temperature for an hour and at 16°C temperature for 2 hours. Hematocrit blood samples still showed normal range in the variations of blood volume height of 3, 4, 5 and 6 cm, withstanding time of 1 and 2 hours, and the temperature of 8°C and 16°C. There was no effect of volume height, standing time and blood storage temperature on hematocrit scores. It can be concluded that hematocrit score is stable at 4 cms blood volume height, 8°C storage temperature for an hour and at room temperature for 2 hours. There is no effect of volume, standing time and blood storage temperature on hematocrit scores.

Page 2 of 2 | Total Record : 11