cover
Contact Name
Abd Kholiq
Contact Email
kholiq@unesa.ac.id
Phone
+6285731570404
Journal Mail Official
jifi@unesa.ac.id
Editorial Address
Jurusan Fisika FMIPA Universitas Negeri Surabaya Kampus Ketintang Unesa, Gedung C3 Lantai 1 Jl Ketintang, Surabaya 60321, Indonesia
Location
Kota surabaya,
Jawa timur
INDONESIA
Inovasi Fisika Indonesia (IFI)
ISSN : 23024216     EISSN : 28301765     DOI : https://doi.org/10.26740/ifi
Jurnal Inovasi Fisika Indonesia(IFI) is a peer-reviewed journal, ISSN: 2302-4216, which is managed and published by the Department of Physics, Faculty of Mathematics and Natural Sciences (FMIPA) Universitas Negeri Surabaya (UNESA). This journal is accessible to all readers and covers developments and research in physics (Materials Physics, Earth Physics and Instrumentation Physics).
Articles 6 Documents
Search results for , issue "Vol 10 No 1 (2021)" : 6 Documents clear
ESTIMASI PARAMETER a-VALUE DAN b-VALUE UNTUK ANALISIS STUDI SEISMISITAS DAN POTENSI BAHAYA BENCANA GEMPA TEKTONIK DI WILAYAH MALUKU UTARA Hilda Risanti; Tjipto Prastowo
Jurnal Inovasi Fisika Indonesia (IFI) Vol 10 No 1 (2021)
Publisher : Jurusan Fisika FMIPA Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (873.849 KB) | DOI: 10.26740/ifi.v10n1.p1-10

Abstract

Abstrak Studi seismisitas dan analisis potensi bahaya bencana seismik di wilayah Maluku Utara dapat dilakukan dengan menentukan parameter a-value dan b-value di wilayah tersebut. Kedua parameter mendiskripsikan level seismisitas dan akumulasi stres mekanik yang disimpan oleh batuan geologi bawah permukaan di wilayah tersebut. Secara prinsip, parameter a-value dan b-value ditentukan dari distribusi frekuensi-magnitudo gempa melalui hukum Gutenberg-Richter. Dalam penelitian ini, hukum Gutenberg-Richter diterapkan pada sumber gempa tektonik dari katalog gempa USGS (http://earthquake.usgs.gov/earthquakes/) selama 2009-2019 dengan kedalaman mencapai 551 km dan variasi magnitudo . Kedua parameter dihitung dengan metode least-squares dan maximum likelihood, di mana perbedaan signifikan a-value dan b-value menurut kedua metode tersebut merefleksikan level akurasi kedua metode tersebut. Metode maximum likelihood memberikan a-value dan b-value yang lebih akurat karena melibatkan penapisan data sebelum proses pengolahan data. Persamaan empiris Gutenberg-Richter yang diperoleh dari metode maximum likelihood adalah , di mana a = 9,73 dan b = 1,39 dengan adalah jumlah kejadian gempa dan adalah gempa dengan magnitudo lebih besar dari (batas bawah magnitudo di mana hukum Gutenberg-Richter berlaku valid). Analisis variasi spasial dan temporal b-value serta variasi spasial a-value berhasil merekonstruksi 3 kejadian gempa relatif besar antara 2009-2019. Kombinasi temuan b-value ≈ 1,4, a-value ≈ 9,7 dan a-value (annual) ≈ 8,7 dengan bantuan ZMAP6,0 menunjukkan bahwa seluruh wilayah Maluku Utara merupakan wilayah yang rentan terhadap bencana gempa dengan frekuensi gempa tinggi yang dipicu seismisitas relatif tinggi di wilayah tersebut. Temuan ini memicu peningkatan kesadaran dan kesiagaan terhadap potensi bahaya bencana gempa tektonik di Maluku Utara. Kata Kunci: seismisitas, bencana seismik, a-value, b-value, hukum Gutenberg-Richter Abstract Seismic studies and corresponding seismic hazard analysis in North Maluku can be performed using determination of a-value and b-value parameters. These parameters describe seismicity level and mechanical stress accumulated in subsurface structure in the region of interest. In principle, a-value and b-value were obtained from frequency-magnitude distribution provided by Gutenberg-Richter law. In this study, this law was generated using earthquake datasets from USGS at http://earthquake.usgs.gov/earthquakes/, where events occurred between 2009-2019 with varying magnitudes and depths to 551 km. The methods included the least-squares and maximum likelihood, where significant differences in the parameters acquired reflect levels of accuracy. The maximum likelihood method yielded accurate results for a-value and b-value due to data declustering prior to data processing. The Gutenberg-Richter law in a log-linear expression was obtained, where a = 9.73 and b = 1.39 with is the cumulative number of occurence and denotes events with magnitudes greater than (defined as the magnitude at which the lower end of the distribution starts to deviate from the Gutenberg-Richter law). Analysis of spatial and temporal variations of b-value and spatial variation of a-value successfully reconstructed 3 occurrences of large magnitudes during 2009-2019. A combined finding of b-value ≈ 1,4, a-value ≈ 9,7 dan a-value (annual) ≈ 8,7 by ZMAP6.0 found for North Maluku reveals that the whole parts of the region are vulnerable to tectonic earthquakes with high frequency owing to relatively high seismicity. This calls for increased awareness of and preparedness for possible seismic threats in North Maluku. Keywords: seismicity, seismic hazard, a-value, b-value, Gutenberg-Richter law
PENENTUAN PARAMETER SEISMIK a-VALUE DAN b-VALUE UNTUK ANALISIS POTENSI BENCANA GEMPA DI WILAYAH MALUKU Teti Apriliani; Tjipto Prastowo
Jurnal Inovasi Fisika Indonesia (IFI) Vol 10 No 1 (2021)
Publisher : Jurusan Fisika FMIPA Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (636.473 KB) | DOI: 10.26740/ifi.v10n1.p11-20

Abstract

Abstrak Kerentanan wilayah Maluku terhadap bencana gempa dipelajari melalui analisis potensi bahaya bencana gempa dengan menentukan parameter seismik a-value dan b-value yang diperoleh dari data statistik gempa tektonik yang terjadi di wilayah tersebut selama kurun waktu tertentu. Kedua parameter seismik mendiskripsikan level seismisitas dan stress mekanik yang disimpan dalam lipatan batuan bawah permukaan. Secara prinsip, kedua parameter ditentukan dari distribusi frekuensi-magnitudo gempa dengan bantuan hukum Gutenberg-Richter. Pada penelitian ini, data sekunder distribusi frekuensi-magnitudo gempa diperoleh dari katalog USGS (http://earthquake.usgs.gov/earthquakes/search/) dengan variasi kedalaman sumber sampai 625 km di bawah permukaan dan variasi magnitudo gempa selama kurun waktu 2009-2019. Perhitungan parameter a-value dan b-value dilakukan dengan metode kuadrat terkecil dan maximum likelihood untuk uji konsistensi dan reliabilitas estimasi kedua parameter tersebut. Estimasi berdasarkan metode maximum likelihood memberikan hasil yang lebih akurat dan stabil karena melibatkan penapisan data sebelum proses pengolahan data dilakukan. Berdasarkan hasil analisis diperoleh persamaan empiris Gutenberg-Richter dengan metode maximum likelihood adalah , di mana dan dengan adalah frekuensi kejadian gempa dan adalah magnitudo yang lebih besar dari , batas bawah magnitudo di mana hukum Gutenberg-Richter masih berlaku. Akurasi hasil estimasi a-value dan b-value dijamin melalui penentuan yang akurat, di mana = 5,0 diperoleh dari plot distribusi frekuensi-magnitudo gempa. Berdasarkan nilai parameter a-value dan b-value, dapat disimpulkan bahwa wilayah Maluku memiliki level seismisitas yang relatif tinggi dan rentan terhadap potensi bencana gempa tektonik yang dipicu oleh aktivitas seismo-tektonik patahan lokal Sorong dan dua zona mikro-subduksi Busur Sangihe dan Busur Halmahera. Kata Kunci: seismisitas Maluku, gempa tektonik, a-value, b-value, hukum Gutenberg-Richter Abstract The vulnerability of Molucca to seismic hazards can be examined through analysis of earthquake-event potential in the region. This analysis can be performed by determining parameters a-value and b-value acquired from datasets of events during a time period, describing seismicity rate and mechanical stress accumulated within local crustal rocks. These parameters were estimated using the Gutenberg-Richter law in this study using frequency-magnitude distribution obtained from the USGS catalog at http://earthquake.usgs.gov/earthquakes/search/ with varying depths to 625 km below the surface and earthquake sizes during 2009-2019. The calculations were carried out using two separate methods, the least squares and the maximum likelihood to search for consistency and reliability of the results. Estimates using the maximum likelihood method provides results that are more accurate and stable due to data filtering prior to data processing. Using the maximum likelihood method selected, the Gutenberg-Richter empirical equation was found to be , where and with denotes the event frequency and represent magnitudes greater than , defined as the lower end of magnitudes above which the Gutenberg-Richter law applies. The accuracy in a-value and b-value estimates was provided by accurate determination of = 5,0 directly obtained from the plot of the frequency-magnitude distribution. Based on the calculated parameters, it can be concluded that Molucca is in the relatively high level of seismicity and prone to seismic threats owing to a combined effect of seismo-tectonic activities from both a local active Sorong fault and subduction processes of Sangihe arc and Halmahera arc. Keywords: Molucca seismicity, tectonic earthquake, a-value, b-value, Gutenberg-Richter law
RANCANG BANGUN ALAT PENGUKUR FREKUENSI RESONANSI DAN CEPAT RAMBAT GELOMBANG PADA DAWAI MENGGUNAKAN SENSOR PICK UP MAGNETIK Friska Dwi Kusuma Wardani; Imam Sucahyo; Metayanti Dewi
Jurnal Inovasi Fisika Indonesia (IFI) Vol 10 No 1 (2021)
Publisher : Jurusan Fisika FMIPA Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (514.894 KB) | DOI: 10.26740/ifi.v10n1.p21-28

Abstract

Abstrak Pengukuran frekuensi resonansi yang sesuai dengan hukum Marsenne dan cepat rambat gelombang dapat dilakukan menggunakan sonometer. Sonometer dapat diterapkan pada alat praktikum laboratorium instrumentasi. Metode pengukuran tersebut yaitu dawai dengan massa per satuan panjang sebesar 0,39; 0,78 dan 1,12 kg/m diletakkan di atas kayu sepanjang 80 cm secara bergantian yang diberi beban di ujung serta pengait di ujung lainnya dengan menambahkan komponen driver coil yang disambungkan dengan sumber input AFG (Audio Frequency Generator) dan dua bridge. Gelombang merambat melalui dawai dan dideteksi oleh sensor pick up magnetik yang disambungkan dengan osiloskop. Pengukuran frekuensi resonansi dilakukan dengan memanipulasi massa per satuan panjang dawai (0,39; 0,78 dan 1,12 kg/m) dan jarak antara driver coil dengan sensor pick up magnetik (0,39 dan 0,18 m). Ketiga manipulasi massa per satuan panjang dawai untuk jarak 0,3 m menghasilkan frekuensi 220,48; 264,20 dan 373,63 Hz serta untuk jarak 0,18 m menghasilkan frekuensi 36,75; 44,03 dan 62,27 Hz. Pengukuran tersebut membuktikan bahwa semakin pendek jarak maka didapatkan frekuensi resonansi yang semakin besar, sedangkan semakin kecil massa per satuan panjang pada dawai maka semakin besar frekuensi resonansi. Kedua hal tersebut sesuai dengan hukum marsenne. Pengukuran cepat rambat gelombang dilakukan dengan memanipulasi massa persatuan panjang dawai 0,39; 0,78 dan 1,12 kg/m. Ketiga manipulasi tersebut diperoleh 354,46; 250,64 dan 209,17 m/s. Oleh karena itu, dapat dijelaskan bahwa semakin kecil massa persatuan panjang dawai maka semakin cepat gelombang merambat. Kata Kunci: Frekuensi resonansi, cepat rambat gelombang, sensor pick up magnetic, massa per satuan panjang, jarak antara driver coil dengan sensor pick up magnetik Abstract Measurement of the resonant frequency in accordance with Marsenne's law and the propagation of the waves was carried out using a sonometer. Sonometer can be applied to laboratory instrumentation lab tools. The measurement method is a string with a mass per unit length of 0.39; 0.78 and 1.12 kg / m are placed on the wood along 80 cm alternately which is loaded at the end and the hook at the other end by adding a coil driver component connected to the AFG (Audio Frequency Generator) input source and two bridges. The waves propagate through the strings and are detected by a magnetic pick-up sensor connected to an oscilloscope. Resonant frequency measurements were performed by manipulating the mass per unit length of the string (0.39; 0.78 and 1.12 kg / m) and the distance between the driver coil and the magnetic pick-up sensor (0.39 and 0.18 m). The three manipulations of mass per unit length of string for a distance of 0.3 m yield a frequency of 220.48; 264.20 and 373.63 Hz and for a distance of 0.18 m the resulting frequency is 36.75; 44.03 and 62.27 Hz. These measurements prove that the shorter the distance, the greater the resonant frequency is obtained, while the smaller the mass per unit length of the string, the greater the resonant frequency. Both of these are in accordance with Marsenne's law. Measurement of the velocity of the wave propagation is done by manipulating the mass of the length of the string 0.39; 0.78 and 1.12 kg / m. The three manipulations were obtained 354.46; 250.64 and 209.17 m / s. Therefore, it can be explained that the smaller the united mass of the strings, the faster the waves propagate. Keywords: Resonant frequency, wave velocity, magnetic pick up sensor, mass per unit length, distance between coil driver and magnetic pick up sensor
ANALISIS PANDU GELOMBANG OPTIK MODEL Y-BRANCH DENGAN FILM TIN (IV) OXIDE NANO SEBAGAI DIVAIS OPTOELEKTRONIKA Novita Dwi Rahayu; Asnawi .
Jurnal Inovasi Fisika Indonesia (IFI) Vol 10 No 1 (2021)
Publisher : Jurusan Fisika FMIPA Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (717.162 KB) | DOI: 10.26740/ifi.v10n1.p29-35

Abstract

Abstrak Pandu gelombang optik adalah salah satu piranti pasif yang penting dalam sistem fotonika dan jaringan komunikasi optik. Piranti dalam pandu gelombang optik dapat mentransmisikan dan memodifikasi sinyal optik dari satu titik ke titik lain yang dapat berfungsi sebagai pembagi daya (power divider), directional coupler, optical combiner, dan optical switch. Tujuan penelitian ini adalah memfabrikasi pandu gelombang optik model Y-branch berbasis material Tin (IV) Oxide (SnO2). Pandu gelombang optik model Y-branch dibuat dengan menggunakan metode laser cutting, dimana substrat pandu gelombang optik adalah akrilik dengan film/core pandu gelombang adalah SnO2 dan PMMA sebagai cladding. Proses kerja laser cutting yaitu dengan memfokuskan sinar laser pada substrat akrilik yang ingin dipotong dengan ukuran 25x15 mm2. Setelah proses pemotongan akrilik kemudian material SnO2 berupa gel dimasukkan ke dalam pandu gelombang Y-branch. Pengukuran output pandu gelombang Y-branch­ dilakukan dengan mengambil gambar laser dari penampang melintang (cross section) pada pandu gelombang kemudian diolah menggunakan perangkat lunak Image-J. Grafik pada perangkat lunak Image-J dapat digunakan untuk menganalisis hasil penelitian. Laser He-Ne dengan panjang gelombang sebesar 632,8 nm sebagai sumber cahaya masukan pada pandu gelombang optik Y-branch. Hasil penelitian menunjukkan bahwa nilai intensitas output 1 dan output 2 yang optimum dari pandu gelombang optik model Y-branch terdapat pada sudut percabangan 50 yaitu sebesar 58,8% (kanal 1) dan 41,2% (kanal 2), hal ini menggambarkan bahwa pandu gelombang Y-branch dengan sudut 50 merupakan pandu gelombang optik yang memiliki nilai luaran yang optimum sebagai pembagi daya (power divider). Dengan demikian, pandu gelombang optik model Y-branch berbasis material Tin (IV) Oxide berpotensi untuk terus dikembangkan sebagai bahan utama pada divais optoelektronika. Kata Kunci: pandu gelombang, pembagi daya, SnO2, laser cutting Abstract Optical waveguides are one of the most important passive devices in photonic systems and optical communication networks. Devices in optical waveguides can transmit and modify optical signals from one point to another which can function as a power divider, directional coupler, optical combiner, and optical switch. The purpose of this research is to fabricate a Y-branch model optical waveguide based on Tin (IV) Oxide (SnO2) material. The Y-branch optical waveguide model is made using laser cutting method, where the optical waveguide substrate is acrylic with the film/core is SnO2 and PMMA as cladding. The work process of laser cutting is by focusing the laser beam on the acrylic substrate to cut with a size of 25x15 mm2. After the acrylic cutting process, the SnO2 material in the form of gel is injected into the Y-branch waveguide. Measurement of the Y-branch waveguide output is done by taking a laser image from the cross section of the waveguide and then processing it using Image-J software. Graphics in Image-J software can be used to analyze research results. He-Ne laser with a wavelength of 632.8 nm as an input light source on a Y-branch optical waveguide. The results showed that the optimum intensity value from the Y-branch optical waveguide model at a branching angle of 50 with 58.8% (channel 1) and 41.2% (channel 2), this illustrates that the Y-branch waveguide with an angle of 50° is an optical waveguide that has an optimum output value as a power divider. Thus, the Y-branch optical waveguide model based on Tin (IV) Oxide material has the potential to be developed as the main material in optoelectronic devices. Keywords: waveguide, power divider, SnO2, laser cutting
PENGEMBANGAN SENSOR GLUKOSA BERBASIS MATERIAL TIN OXIDE NANO DENGAN MENGGUNAKAN FIBER BRAGG GRATING Diptya Latifa Rohadi Latifa Rohadi; Asnawi .
Jurnal Inovasi Fisika Indonesia (IFI) Vol 10 No 1 (2021)
Publisher : Jurusan Fisika FMIPA Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (528.436 KB) | DOI: 10.26740/ifi.v10n1.p36-42

Abstract

Abstrak Diabetes melitus merupakan masalah kesehatan masyarakat yang disebabkan oleh faktor genetik maupun usia. Upaya mencegah penambahan jumlah penderita diabetes maka perlu adanya pemantauan kadar glukosa dalam tubuh. Pemantauan dilakukan dengan mengukur kadar glukosa dalam darah dengan cara penusukan jari yang menyebabkan ketidaknyamanan pada pasien. Maka dikembangkan metode pengukuran non-invasive yang sesuai dengan tujuan penelitian ini yaitu mendeskripsikan cara dan hasil pengembangan sensor glukosa berbasis material tin oxide nano dengan menggunakan fiber bragg grating (FBG). Sensor dengan menggunakan fiber bragg grating berbasis optik material tin oxide nano memiliki kepekaan yang tinggi dan periode reaksi yang cepat sebagai sensor glukosa. Hasil penelitian menunjukkan sensitifitas yang terjadi terkait pergeseran nilai indeks bias dan nilai panjang gelombang pada larutan glukosa. Pada konsentrasi glukosa sebesar 10% terjadi pergeseran indeks bias yaitu 1,345. Pergeseran nilai panjang gelombang terjadi pada indeks bias 1,332 yaitu 1550,072. Dengan demikian adanya pergeseran panjang gelombang terhadap indeks bias larutan glukosa dari berbagai konsentrasi glukosa ini menunjukkan bahwa pengembangan FBG berbasis material tin oxide nano dapat digunakan sebagai sensor glukosa. Sensor fiber bragg grating dengan menggunakan pelapis nanomaterial SnO2 dapat diimplementasikan dengan menggunakan saliva pasien diabetes melitus (DM). Kata kunci: Fiber Bragg Grating, Diabetes Melitus, SnO2 Abstract Diabetes mellitus is a public health problem caused by genetic factors and age. In efforts to prevent the increase in the number of diabetics, it is necessary to monitor glucose levels in the body. Monitoring is carried out by measuring the level of glucose in the blood by means of pricking a finger which causes discomfort to the patient. So a non-invasive measurement method was developed that is in accordance with the objectives of this study, namely to describe the methods and results of the development of a glucose sensor based on tin oxide nanomaterial using a fiber Bragg grating (FBG). The sensor using optical fiber Bragg grating of tin oxide nanomaterial has high sensitivity and a fast reaction period as a glucose sensor. The results showed that the sensitivity occurred related to the shift in the refractive index value and the wavelength value in the glucose solution. At a glucose concentration of 10%, there was a shift in the refractive index, namely 1.345. The shift in the wavelength value occurs at the refractive index of 1.332 which is 1550.072. Thus, the shift in wavelength towards the refractive index of glucose solutions from various glucose concentrations indicates that the development of FBG based on tin oxide nanomaterial can be used as a glucose sensor. The fiber Bragg grating sensor using the SnO2 nanomaterial coating can be implemented using the saliva of diabetes mellitus (DM) patients. Keywords: Fiber Bragg Grating, Diabetes Mellitus, SnO2
UJI SENSITIVITAS SENSOR TCS230 BERBASIS ARDUINO UNO SEBAGAI ALAT PENDETEKSI WARNA BAGI PENDERITA BUTA WARNA Daffa Mahendra; Dzulkiflih .
Jurnal Inovasi Fisika Indonesia (IFI) Vol 10 No 1 (2021)
Publisher : Jurusan Fisika FMIPA Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (841.182 KB) | DOI: 10.26740/ifi.v10n1.p43-51

Abstract

Abstrak Pengujian terhadap sensor TCS230 memberikan peluang untuk mengetahui sensitivitas dan tingkat kesalahan (error) sehingga dapat membantu penderita kelainan buta warna (color blindness) dalam mengidentifikasi suatu objek warna. Fokus pada penelitian ini adalah untuk meneliti sensitivitas dari Sensor TCS230 terhadap warna RGB pada suatu objek warna. Metode penelitian yang dilakukan oleh peneliti secara kuantitatif menggunakan sumber data primer. Pengujian data menggunakan metode MSE (Mean Square Error) dan ACPP (Algoritma Closest Pair Point). Hasil dari penelitian menggunakan metode MSE menemukan bahwa pada uji warna merah (R/Red) memiliki nilai error paling kecil sebesar 2,82%, warna biru memiliki nilai error paling kecil sebesar 10,44%, warna hijau memiliki nilai error paling kecil sebesar 11,33%, warna putih memiliki nilai error paling kecil sebesar 4,50% dan warna kuning memiliki nilai error paling kecil sebesar 7,90%. Hasil penelitian menggunakan metode ACPP menghasilkan nilai error pada sampel 1 (satu) sebesar 6,54% dengan warna terdekat yaitu merah koral dan sampel 2 (dua) sebesar 14,90% dengan warna terdekat yaitu warna merah salmon gelap. Peneliti mengambil kesimpulan bahwa pada metode MSE memiliki tingkat error rendah pada jarak 1 cm dan semakin besar jarak maka frekuensi yang diperlukan semakin besar serta metode ACPP memiliki jarak warna terdekat dengan kesesuain mayoritas sampel warna. Kata Kunci: ACPP, buta warna, frekuensi, jarak, MSE, Abstract Testing the TCS230 sensor provides an opportunity to determine the sensitivity and error rate so as to help people with color blindness in identifying a color object. The focus of this study was to examine the sensitivity of the TCS230 Sensor to RGB colors on a color object. Research methods conducted by researchers quantitatively using primary data sources. Data testing using MSE (Mean Square Error) and ACPP (The Closest Pair Point Algorithm) methods. The results of the study using MSE method found that in the red color test (R/Red) had the smallest error value of 2.82%, blue had the smallest error value of 10.44%, green color had the least error value of 11.33%, white had the smallest error value of 4.50% and yellow had the least error value of 7.90%. The results of the study using ACPP method produced a error value in the sample of 1 (one) of 6,54% with the closest color of coral red and 2 (two) samples of 14,90% with the nearest color of dark salmon red. The researchers concluded that in the MSE method has a low error rate at a distance of 1 cm and the greater the distance, the frequency required the greater and the ACPP method has the closest color distance to the majority of color samples. Keywords: ACPP, color blindness, distance, frequency, MSE.

Page 1 of 1 | Total Record : 6