RANCANG BANGUN SISTEM NURSE CALL TERHADAP KEGAGALAN INFUSE PUMP MENGGUNAKAN MIKROKONTROLER ATmega8535 Heru Heru; Fitria Priyulida
JURNAL MUTIARA ELEKTROMEDIK Vol 6 No 1 (2022): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (363.353 KB) | DOI: 10.51544/elektromedik.v6i1.3258

Abstract

The infuse pump is a media device used to provide the patient's body fluids with a certain time and amount. In giving intravenous fluids can have a bad effect on patients. The infusion that is currently used is still manual where errors such as clogging or monitoring of fluids. Therefore, planning an infusion pump that can send notifications when the infusion fluid runs out.In designing this tool aims to design a nurse call on an infusion pump using a microcontroller and sent via Bluetooth to the nurse call. On the Bluetooth call nurse receiving and sending it to the microcontroller will send it to the LCD and the Buzzer sounds if it goes to the input.In this final design using the ATmega8535 microcontroller which will read the incoming data via Bluetooth. LCD and buzzer are used so nurses can see and hear when the infusion fluid runs out.
RANCANG BANGUN HEATER PADA BLOOD WARMER DENGAN TAMPILAN LCD BERBASISI MIKROKONTROLLER ATMega8535 Flaviana Poprita Liuk Mau; Dzia Ur Ridha
JURNAL MUTIARA ELEKTROMEDIK Vol 6 No 1 (2022): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (334.284 KB) | DOI: 10.51544/elektromedik.v6i1.3259

Abstract

Blood warmer is a tool that is used to warm blood in the process of blood transfusion. Inside the blood warmer there are several main parts that must be considered, the main part that must be considered is the heater part. With the main aim to maintain the temperature in the blood cantomate so that no clotting occurs. The design of this tool aims to obtain the design of blood builder using the LM35 sensor as a temperature indicator to be displayed on the LCD. This research starts from the stages of collecting various sources, gathering information designing tool products, designing and perfoming function tests. Device hard covening design circuit supply power, circuit minumum system ATMega8535 microcontroller, a temperature sensor circuit. circuit,heater driver circuit LCD. While design for device soft covering programming basic language complier. Principle work from system on a whole namely : temperature sensor circuit will give input on the microcontrller for processed and produce output in the fom of hot via heater
RANCANG BANGUN SISTEM PENGAMANAN TRANSFUSI DARAH BERBASIS MIKROKONTROLER ATMega 8535 Raja Embun Sari; Rizal Thalib
JURNAL MUTIARA ELEKTROMEDIK Vol 6 No 1 (2022): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (390.544 KB) | DOI: 10.51544/elektromedik.v6i1.3260

Abstract

Blood warmer is a tool that is used to warm blood in the process of blood transfusion. Inside the blood warmer there are several main parts that must be considered, in the main part that must be considered is the blood fluid detector section. With the main purpose so that blood does not rise again fill the blood bag. The design of this tool aims to get the design of a security system for blood transfusion by using a photodiode detector as an indicator of blood flow that will be displayed in the form of sound. This research starts from the stages of collecting various sources, gathering information, designing tool products, designing and performing function tests. The hardware includes the design of the power supply circuit, the minimum system circuit of the ATMega8535 microcontroller, the liquid blood detector circuit, the buzzer circuit, and the servo motor circuit. While the design for software includes basic complier language programming. The working principle of the overall system is: The photodiode detector circuit will provide input to the microcontroller to be processed and produce output in the form of buzzer and servo motor closing the hose
ANALISA PEMELIHARAAN ALAT ELECTROLYTE ANALYZER MERK SPOTCHEM EL SE-1520 Geosandy Nagata; Fitria Priyulida
JURNAL MUTIARA ELEKTROMEDIK Vol 6 No 1 (2022): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (343.997 KB) | DOI: 10.51544/elektromedik.v6i1.3261

Abstract

Health equipment is one of the factors that holds important equipment in providing health services to the community so that maintenance activities are needed for the sake of survival and the quality of the results of the tool, one of which is an electrolyte analyzer.Electrolyte analyzer is a laboratory equipment needed to determine electrolyte levels in the human body
ANALISIS KALIBRASI SYRINGE PUMP Awaluddin Laia; Yulizham Yulizham
JURNAL MUTIARA ELEKTROMEDIK Vol 6 No 1 (2022): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (337.929 KB) | DOI: 10.51544/elektromedik.v6i1.3262

Abstract

Sustainable health services need to be supported by equipment that is always in a ready-to-use condition and can be functioned properly. One of them is the pumpa syringe tool, through the provision of suitable equipment, preventive maintenance is needed including periodic maintenance and implementation of testing and calibration. The method used in this research is quantitative research with analytical descriptive method which aims to analyze the results of the syringe pump calibration using an infusion pump analyzer and also aims to determine the results of the data obtained after observing the workflow of the tool.From the results of examinations that have been carried out on the syringe pump calibration using the infusion pump analyzer at the Medan Health Facility Security Center (BPFK), the results obtained from the flow rate test of the syringe pump tool at the 10 mL/h point are 9.7 +- 0.4 mLh, so the final result is 9.7 + 0.4 = 10.1 mL/h or 9.7 - 0.4 = 9.3 mL h, it can be concluded that the measurement results that have been made are still within the 10% tolerance limit of the 10 mL/h. Measurement point value Occlusion test the syringe pump tool at the point of 100 mL/h yields 9.97+- 0.4 psi, so the final result is 9.97 + 0,4 = 10.37 psi or 9.97 - 0.4 = 9.57 psi, so it can be concluded that the measurement results that has been doneis still within the tolerance limit of <- 20 psi In performing then calibration.