cover
Contact Name
Rudi Kurnianto
Contact Email
rudi.kurnianto@ee.untan.ac.id
Phone
+6285252665807
Journal Mail Official
j3eit@untan.ac.id
Editorial Address
Jl. Prof. Dr. Hadari Nawawi, Pontianak 78124, Indonesia
Location
Kota pontianak,
Kalimantan barat
INDONESIA
Journal of Electrical Engineering, Energy, and Information Technology
ISSN : -     EISSN : 30261856     DOI : http://dx.doi.org/10.26418/j3eit.v11i2
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) (E-ISSN: 3026-1856) is the latest name for the JTE UNTAN, which underwent a name change. This journal has been in circulation within UNTAN since 2013 under its previous name. The name change reflects an evolution in the topics covered by the journal, encompassing the fields of electrical engineering, energy, and information technology. With the establishment of J3EIT, it is expected to become a significant resource for the academic and research community in this discipline, fostering the exchange of knowledge and innovation among professionals in the field of electrical engineering and related areas. By consistently publishing high-quality scientific papers, this journal is expected to play a vital role in advancing knowledge in its field. J3EIT is published three times a year, April, August and December.
Articles 16 Documents
Search results for , issue "Vol 4, No 2: Juli 2016" : 16 Documents clear
EVALUASI RUGI-RUGI JARINGAN YANG DILAYANI OLEH JARINGAN PLTS TERPUSAT SIDING Didik Martono .
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 4, No 2: Juli 2016
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v4i2.16528

Abstract

Abstrak- Indonesia secara geografis sebagai Negara tropis, melintang garis katulistiwa berpotensi energi surya yang cukup baik. Bagi masyarakat yang tinggal di daerah kabupaten dan pedesaan, penyedian energi listrik merupakan masalah utama. Karena jaringan listrik PLN belum menjangkau pada daerah tersebut. Solusi yang tepat untuk mengatasi ketiadaan energi listrik di daerah tersebut adalah mengubah cahaya matahari yang melimpah menjadi energi listrik menggunakan teknologi  photovoltaic. Sistem penyediaan listrik seperti ini disebut Pembangkit Listrik Tenaga Surya (PLTS). PLTS terpusat 40 KW di Desa Siding Kecamatan Siding Kabupaten Bengkayang merupakan salah satu pembangkit listrik yang mendukung penyedian energi listrik PLN. Analisis rugi-rugi pada jaringan perlu dilakukan sebagai bahan pertimbangan dalam pengembangan sistem distribusi di masa yang akan datang. Dari hasil analsis yang telah dilakukan, diketahui bahwa :  persentase jatuh tegangan terbesar pada fasa R sebesar 3,215% atau 212,93 Volt, fasa S sebesar 2,930% atau 213,55 Volt, dan fasa T sebesar 3,258% atau 212,83 Volt. Dari persentase jatuh tegangan terbesar pada masing-masing fasa, sistem distribusi jaringan tegangan rendah PLTS Siding masih dalam ketentuan SPLN No.72 Tahun 1987, karena masih dibawah toleransi yaitu 4%. Sedangkan total rugi-rugi daya aktif sistem distribusi jaringan tegangan rendah PLTS Siding merupakan penjumlahan dari total rugi-rugi daya aktif pada masing-masing fasa sebesar 596,87 Watt atau sebesar 1,49%. Kata kunci : photovoltaic, PLTS terpusat, persentase jatuh tegangan, rugi-rugi daya aktif
EVALUASI PENERAPAN METODE PENTANAHAN NETRAL RESISTANSI TINGGI PADA GENERATOR DI PLTD SUNGAI RAYA Rifo Ardo Wiguna .
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 4, No 2: Juli 2016
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v4i2.16846

Abstract

Abstrak-Penelitian ini bertujuan untuk melakukan evaluasi terhadap kinerja sistem pentanahan di PLTD Sungai Raya. Pengumpulan data dilakukan dengan data sekunder yang diperoleh dari PT.PLN (Persero) Area Pengatur Distribusi dan Penyaluran (APDP) Kalimantan Barat. Metode yang digunakan dalam penelitian ini adalah pengolahan metode 3 titik, pada penelitian terdapat 13 titik pengukuran grounding pada PLTD Sungai Raya. Pegukuran titik grounding ditentukan berdasarkan pertimbangan yang dilakukan oleh PLTD Sungai Raya untuk melakukan proteksi pada bangunan, peralatan dan mesin yang ada pada lokasi PLTD Sungai Raya. Hasil pengukuran grounding masih standar dengan hasil pengukuran grounding tertinggi yaitu pada dititik 1 sebesar 4,81 ohm. Sedangkan untuk hasil pengukuran grounding pada titik lainnya berada di nilai rata-rata 0,50 ohm. Setelah pengolahan data, maka dapat disimpulkan bahwa penerapan metode pentanahan netral resistansi tinggi pada generator di PLTD Sungai Raya dilihat dari jenis pembumian, resistansi pembumian, dan elektroda pembumian yang digunakan telah memenuhi persyaratan standarisasi sesuai dengan PUIL 2000. Sehingga dari hasil evaluasi dapat dikategorikan sudah efektif. Kata Kunci: Evaluasi, Pentanahan Netral, Pengukuran Tahanan Tanah, Metode Tiga Titi
Rancang Bangun Sistem Peringatan Dini Dan Pelacakan Pada Kendaraan Sepeda Motor Dengan Menggunakan Mikrokontroler Arduino Nano Gusmanto .
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 4, No 2: Juli 2016
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v4i2.17758

Abstract

Abstrak.-- Kasus pencurian kendaraan sepeda motor sering terjadi di kota Pontianak, hal ini terbukti dengan banyaknya keluhan kehilangan kendaraan di masyarakat. Pada tugas akhir ini dirancanglah sebuah sistem peringatan dini dengan menggunakan mikrokontroler arduino nano, dengan tujuan dapat menginformasikan terjadinya pencurian dengan cepat. Lingkup kerja alat ini terbatas pada dua kondisi pencurian, kondisi pertama kontak kunci dinyalakan secara paksa dan kondisi kedua kendaraan dipindahkan posisinya lebih dari 60 meter. Untuk mengaktifkan sistem keamanan pada saat kendaraan diparkirkan dapat menggunakan dua pilihan, yaitu menggunakan remote dan SMS. Alat ini menggunakan modul GSM dan modul GPS, modul GSM ini berfungsi untuk mengirim informasi peringatan pada saat terjadinya pencurian. selain itu modul GSM juga memberikan informasi posisi kendaraan dalam bentuk titik koordinat berupa link Google Maps dan mengetahui kondisi kendaraan dengan mengirimkan SMS ke mikrokontroler. Sedangkan modul GPS mempunyai dua fungsi yaitu sebagai sistem pelacakan dan sebagai sensor posisi untuk mendeteksi perpindahan kendaraan saat diparkirkan. Saat terjadi pecurian sistem keamanan akan mengaktifkan buzzer dan memutuskan kabel kontak kunci sehingga kendaraan tidak bisa dinyalakan. Dari hasil pengujian pada alat ini, pengendalian menggunakan remote dapat menjangkau kurang dari 25 meter dan respon mikrokontroler dalam menginformasikan SMS peringatan terjadinya pencurian ke pemilik kendaraan memerlukan waktu 6-12 detik. Pengujian modul GPS pada kondisi kendaraan diparkirkan, pembacaan data GPS dapat berubah dalam radius 51 meter. Perubahan data GPS tersebut menjadi jarak referensi untuk sensor posisi pada modul GPS.     Kata kunci: pencurian, ardunio nano, GPS, sensor posisi, peringatan dini.
ANALISIS NILAI LEVEL DAYA TERIMA MENGGUNAKAN PENDEKATAN MODEL PROPAGASI WALFISCH-IKEGAMI Retno Niti Amalia .
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 4, No 2: Juli 2016
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v4i2.16277

Abstract

ABSTRACT- Propagation model in cellular communication is needed to know the characteristic of propagation and it can be used to predict the value of receiving power level cellular network. The value of receiving power level is one of the indicator to see the signal quality and the influence in the prediction of beam coverage in BTS that is usually called coverage. Propagation model that would be used in this research was outdoor Walfisch-Ikegami. This research located at city center with taking the receiving power that radiated from BTS Santika that taken by using measurement from software G-NetTrack Lite in 3G Signal. The purpose of this research was to analyze the receiving power level by using Walfisch-Ikegami propagation model approach. The value of receiving power known by Walfisch-Ikegami propagation calculation and measurement by using G-NetTrack Lite towards 5 points street around BTS Santika was Agus Salim  Street,  Merapi  Street,  Antasari  Street, Diponegoro Street, and Teuku Cik Ditiro Street. The result of propagation model calculation was founded as follow, -102.21 dBm, -89.68 dBm, -82.46 dBm, -96.05 dBm, and -76.49 dBm. The result of measurement by using the G-NetTrack Lite was founded as follow, -71 dBm, -73 dBm, -75 dBm, -81 dBm, and -75 dBm. The smaller the loss value or attenuation value, the value of receiving power that was founded would be closer with standard which has been set. The bigger the loss value or attenuation value, so the value of receiving power that was founded would be further with standard which has been set. Keywords:      Received      Power,      Walfisch-Ikegami Propagation Model, Receive Signal Code Power.
PERHITUNGAN JATUH TEGANGAN DAN SUSUT DAYA SERTA UPAYA PERBAIKAN PENYALURAN DAYA LISTRIK PADA PT. PLN (PERSERO) RAYON SAMBAS Ardhi Surya Nopianto .
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 4, No 2: Juli 2016
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v4i2.16967

Abstract

Abstrak - Profil tegangan dan susut daya diakibatkan oleh rugi-rugi daya di jaringan karena tingginya impedansi jaringan, karakteristik induktif jaringan listrik serta beban induktif yang tersambung pada jaringan. Dalam kenyataannya, adanya susut daya listrik pada penyediaan energi listrik adalah sesuatu yang tidak bisa dihindarkan. Meski demikian susut energi yang terjadi dalam proses penyaluran dan distribusi energi listrik merupakan suatu pemborosan energi apabila tidak dikendalikan secara optimal. Berdasarkan analisis perhitungan persentase jatuh tegangan pada penyulang Galing dan penyulang Kawakan PT. PLN (Persero) Rayon Sambas, pada penyulang Galing persentase jatuh tegangan maksimum terdapat pada bus 43 (GD 229) yaitu sebesar 5,470%, dengan besar tegangan 18,042 KV. Sedangkan pada penyulang Kawakan persentase jatuh tegangan maksimum terdapat pada bus 14 (GD 170) yaitu sebesar 2,107%, dengan besar tegangan 19,5786 KV. Hasil perhitungan setelah divalidasi dengan metode injeksi arus terdapat perbedaan, disebabkan pada penelitian ini merupakan pendekatan perhitungan jatuh tegangan antar saluran dimana rugi-rugi daya pada saluran diabaikan. Total rugi-rugi daya aktif yang terjadi pada penyulang Kawakan sebesar 9,222 KW, dan pada penyulang Galing sebesar 54,880 KW. Salah satu upaya perbaikan penyaluran daya yaitu dengan mengganti luas penampang penghantar pada seksi saluran yang mengalami persentase jatuh tegangan yang melebihi standar yang diijinkan. Dengan mengganti penghantar AAAC 35 mm2 menjadi AAAC 150 mm2 pada beberapa cabang penyulang Galing yang menghasilkan persentase jatuh tegangan yang besar, mengakibatkan tegangan bus atau gardu-gardu penyulang Galing meningkat, serta menurunkan rugi-rugi daya aktif total yang sebelumnya sebesar 54,880 KW menjadi 49,842 KW. Kata kunci : profil tegangan, persentase jatuh tegangan, rugi-rugi daya aktif, upaya perbaikan
ANALISIS QUALITY OF SERVICE DAN PENERIMAAN SINYAL WIMAX 3.3 GHZ PADA KONDISI LINE OF SIGHT DAN KONDISI NON LINE OF SIGHT PT APLIKANUSA LINTASARTA PONTIANAK Rendi Andika .
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 4, No 2: Juli 2016
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v4i2.16973

Abstract

Abstract PT. Aplikanusa Lintasarta area Pontianak sebagai penyedia layanan Internet dan jaringan Virtual Private Network(VPN). PT. Lintasarta menyediakan berbagai media akses telekomunikasi data salah satunya menggunakan media akses Broadband Wireless Access (BWA) yang merupakan teknologi WiMAX dimana antena pemancar WiMAX PT. Lintasarta terletak di BTS Arena Remaja milik PT. Indosat Jl. Sukajaya. Kota Pontianak yang merupkan daerah yang berkembang dimana terdapat pembangunan insfratuktur dan gedung – gedung tinggi yang memungkinkan dalam performansi WiMAX yang dipancarkan dari Base Station (BS) ke Subscriber Station (SS) mengalami Non-Line of Sight (NLOS) sehingga pada penelitian akan dilakukan analisis kekuatan sinyal penerimaan WiMAX yang didapatkan dalam percobaan keadaan Line of Sight (LOS) dan Non-Line of Sight (NLOS) atau keadaan terhalang gedung serta menganalisa pengaruh terhadap modulasi dan bandwidthnya.  Permasalahan yang terjadi kualitas penerimaan sinyal WiMAX dalam keadaan LOS dan NLOS (terhalang) oleh gedung serta bagaimana pengaruh terhadap modulasi dan bandwidth yang didapatkan serta parameter QoS adalah delay/latency, Packet Loss, dan throughput. Sedangakan untuk menilai kekuatan sinyal penerima digunakan  Receive Symbol Strengh. Berdasarkan hasil perhitungan, maka dapat disimpulkan nilai kualitas layanan berdasarkan QoS untuk kondisi LOS dan NLOS yaitu : Pada parameter delay dari hasil capture aplikasi WiMAX. Pada kondisi LOS rata-rata sebesar 9,18 ms dan pada kondisi NLOS rata-rata sebsar 14,32 ms. Pada parameter delay dari hasil capture aplikasi WiMAX. Pada kondisi LOS rata-rata sebesar 83,403 % dan pada kondisi NLOS rata-rata sebsar 69,58%. Pada parameter delay dari hasil capture aplikasi WiMAX. Pada parameter Packet Loss kondisi LOS rata-rata sebesar 0% dan pada kondisi NLOS rata-rata sebesar 0%. Kekuatan sinyal penerima untuk kondisi LOS berupa QAM dengan nilai RSSI rata-rata sebesar -64,06 dBm. Kekuatan sinyal penerima untuk kondisi NLOS berupa QAM, QPSK dan BPSK dengan nilai RSSI rata-rata sebesar -83,96 dBm. Kata kunci - Quality of Service, Delay, Jitter, Throughtput, Packet Loss dan Receive Symbol Strengh.

Page 2 of 2 | Total Record : 16