cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kota adm. jakarta selatan,
Dki jakarta
INDONESIA
Mechatronics, Electrical Power, and Vehicular Technology
ISSN : 20873379     EISSN : 20886985     DOI : -
Core Subject : Engineering,
Mechatronics, Electrical Power, and Vehicular Technology (hence MEV) is a journal aims to be a leading peer-reviewed platform and an authoritative source of information. We publish original research papers, review articles and case studies focused on mechatronics, electrical power, and vehicular technology as well as related topics. All papers are peer-reviewed by at least two referees. MEV is published and imprinted by Research Center for Electrical Power and Mechatronics - Indonesian Institute of Sciences and managed to be issued twice in every volume. For every edition, the online edition is published earlier than the print edition.
Arjuna Subject : -
Articles 24 Documents
Search results for , issue "Vol 4, No 1 (2013)" : 24 Documents clear
Maximum Power Point Tracking of Photovoltaic System for Traffic Light Application Muhida, Riza; Mohamad, Nor Hilmi; Legowo, Ari; Irawan, Rudi; Astuti, Winda
Journal of Mechatronics, Electrical Power and Vehicular Technology Vol 4, No 1 (2013)
Publisher : Research Centre for Electrical Power and Mechatronics, Indonesian Istitutes of Sciences

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (641.854 KB) | DOI: 10.14203/j.mev.2013.v4.57-64

Abstract

Photovoltaic traffic light system is a significant application of renewable energy source. The development of the system is an alternative effort of local authority to reduce expenditure for paying fees to power supplier which the power comes from conventional energy source. Since photovoltaic (PV) modules still have relatively low conversion efficiency, an alternative control of maximum power point tracking (MPPT) method is applied to the traffic light system. MPPT is intended to catch up the maximum power at daytime in order to charge the battery at the maximum rate in which the power from the battery is intended to be used at night time or cloudy day. MPPT is actually a DC-DC converter that can step up or down voltage in order to achieve the maximum power using Pulse Width Modulation (PWM) control. From experiment, we obtained the voltage of operation using MPPT is at 16.454 V, this value has error of 2.6%, if we compared with maximum power point voltage of PV module that is 16.9 V. Based on this result it can be said that this MPPT control works successfully to deliver the power from PV module to battery maximally.
Effect of Regenerative Organic Rankine Cycle (RORC) on the Performance of Solar Thermal Power in Yogyakarta, Indonesia Pikra, Ghalya; Purwanto, Andri Joko; Santoso, Adi
Journal of Mechatronics, Electrical Power and Vehicular Technology Vol 4, No 1 (2013)
Publisher : Research Centre for Electrical Power and Mechatronics, Indonesian Istitutes of Sciences

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (290.736 KB) | DOI: 10.14203/j.mev.2013.v4.25-32

Abstract

This paper presents effect of Regenerative Organic Rankine Cycle (RORC) on the performance of solar thermal power in Yogyakarta, Indonesia. Solar thermal power is a plant that uses solar energy as heat source. Indonesia has high humidity level, so that parabolic trough is the most suitable type of solar thermal power technology to be developed, where the design is made with small focal distance. Organic Rankine Cycle (ORC) is a Rankine cycle that use organic fluid as working fluid to utilize low temperature heat sources. RORC is used to increase ORC performance. The analysis was done by comparing ORC system with and without regenerator addition. Refrigerant that be used in the analysis is R123. Preliminary data was taken from the solar collector system that has been installed in Yogyakarta. The analysis shows that with 36 m total parabolic length, the resulting solar collector capacity is 63 kW, heat input/evaporator capacity is determined 26.78 kW and turbine power is 3.11 kW for ORC, and 3.38 kW for RORC. ORC thermal efficiency is 11.28% and RORC is 12.26%. Overall electricity efficiency is 4.93% for ORC, and 5.36% for RORC. With 40°C condensing temperature and evaporation at 10 bar saturated condition, efficiency of RORC is higher than ORC. Greater evaporation temperature at the same pressure (10 bar) provide greater turbine power and efficiency.
Front Cover MEV Vol 4 Iss 1 Muharam, Aam
Journal of Mechatronics, Electrical Power and Vehicular Technology Vol 4, No 1 (2013)
Publisher : Research Centre for Electrical Power and Mechatronics, Indonesian Istitutes of Sciences

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14203/j.mev.2013.v4.%p

Abstract

Modeling of Electric Field Around 100 MVA 150/20 kV Power Transformator using Charge Simulation Method Rachman, Noviadi Arief; Risdiyanto, Agus; Ramdan, Ade
Journal of Mechatronics, Electrical Power and Vehicular Technology Vol 4, No 1 (2013)
Publisher : Research Centre for Electrical Power and Mechatronics, Indonesian Istitutes of Sciences

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14203/j.mev.2013.v4.33-40

Abstract

Charge Simulation Method is one of the field theory that can be used as an approach to calculate the electromagnetic distribution on the electrical conductor. This paper discussed electric field modeling around power transformator by using Matlab to find the safety distance. The safe distance threshold of the electric field to human health refers to WHO and SNI was 5 kV/m. The specification of the power transformator was three phases, 150/20 kV, and 100 MVA. The basic concept is to change the distribution charge on the conductor or dielectric polarization charge with a set of discrete fictitious charge. The value of discrete fictitious charge was equivalent to the potential value of the conductor, and became a reference to calculate the electric field around the surface contour of the selected power transformator. The measurement distance was 5 meter on each side of the transformator surface. The results showed that the magnitude of the electric field at the front side was 5541 V/m, exceeding the safety limits.
Preface MEV Vol 4 Iss 1 Muharam, Aam
Journal of Mechatronics, Electrical Power and Vehicular Technology Vol 4, No 1 (2013)
Publisher : Research Centre for Electrical Power and Mechatronics, Indonesian Istitutes of Sciences

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (61.424 KB) | DOI: 10.14203/j.mev.2013.v4.%p

Abstract

Autoregressive Integrated Adaptive Neural Networks Classifier for EEG-P300 Classification Soetraprawata, Demi; Turnip, Arjon
Journal of Mechatronics, Electrical Power and Vehicular Technology Vol 4, No 1 (2013)
Publisher : Research Centre for Electrical Power and Mechatronics, Indonesian Istitutes of Sciences

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (494.761 KB) | DOI: 10.14203/j.mev.2013.v4.1-8

Abstract

Brain Computer Interface has a potency to be applied in mechatronics apparatus and vehicles in the future. Compared to the other techniques, EEG is the most preferred for BCI designs. In this paper, a new adaptive neural network classifier of different mental activities from EEG-based P300 signals is proposed. To overcome the over-training that is caused by noisy and non-stationary data, the EEG signals are filtered and extracted using autoregressive models before passed to the adaptive neural networks classifier. To test the improvement in the EEG classification performance with the proposed method, comparative experiments were conducted using Bayesian Linear Discriminant Analysis. The experiment results show that the all subjects achieve a classification accuracy of 100%.
IMU Application in Measurement of Vehicle Position and Orientation for Controlling a Pan-Tilt Mechanism Saputra, Hendri Maja; Abidin, Zainal; Rijanto, Estiko
Journal of Mechatronics, Electrical Power and Vehicular Technology Vol 4, No 1 (2013)
Publisher : Research Centre for Electrical Power and Mechatronics, Indonesian Istitutes of Sciences

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1030.099 KB) | DOI: 10.14203/j.mev.2013.v4.41-50

Abstract

This paper describes a modeling and designing of inertial sensor using Inertial Measurement Unit (IMU) to measure the position and orientation of a vehicle motion. Sensor modeling is used to derive the vehicle attitude models where the sensor is attached while the sensor design is used to obtain the data as the input to control the angles of a pan-tilt mechanism with 2 degrees of freedom. Inertial sensor Phidget Spatial 3/3/3, which is a combination of 3-axis gyroscope, 3-axis accelerometer and 3-axis magnetometer, is used as the research object. Software for reading the sensor was made by using Matlabâ„¢. The result shows that the software can be applied to the sensor in the real-time reading process. The sensor readings should consider several things i.e. (a) sampling time should not be less than 32 ms and (b) deviation ratio between measurement noise (r) and process noise (q) for the parameters of Kalman filter is 1:5 (i.e. r = 0.08 and q = 0.4).
Appendix MEV Vol 4 Iss 1 Muharam, Aam
Journal of Mechatronics, Electrical Power and Vehicular Technology Vol 4, No 1 (2013)
Publisher : Research Centre for Electrical Power and Mechatronics, Indonesian Istitutes of Sciences

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (46.316 KB) | DOI: 10.14203/j.mev.2013.v4.%p

Abstract

Optimization for Biogas Power Plants using Automatic Control of Gas Pressures Candra, Dodiek Ika; Tamayo, Camilo Andreas Wilches
Journal of Mechatronics, Electrical Power and Vehicular Technology Vol 4, No 1 (2013)
Publisher : Research Centre for Electrical Power and Mechatronics, Indonesian Istitutes of Sciences

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (404.64 KB) | DOI: 10.14203/j.mev.2013.v4.9-16

Abstract

In many cases, gas storages on biogas power plants are not used optimally to store gas as much as their capacity. The digester is sometimes overload to store gas and the controller cannot deliver gas to other storage. Consequently, gas is often released from digester to avoid over pressure. At the end, biogas power plant has less efficiency. Hence, a mechanism to control gas pressure to make different pressure between its storages is required. Fans were used to manipulate the most majority system pressures on a biogas power plant using frequency converters. Measurements, simulations, and experiments were conducted to create a new system on a biogas power plant. A controller, Programmable Logic Controller was used to control the entire system pressure using Proportional-Integral-Derivative algorithm. When the gas pressures are not in the allowable range of pressure, then the controller changes the fans’ frequency to the desired conditions. As a result, gas moves to another storage and system pressures are in the allowable range.
Quality Evaluation of the Modified Diesel-Electric Train (KRDE) Hidayat, Taufik; Alam, Hilman Syaeful
Journal of Mechatronics, Electrical Power and Vehicular Technology Vol 4, No 1 (2013)
Publisher : Research Centre for Electrical Power and Mechatronics, Indonesian Istitutes of Sciences

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (335.561 KB) | DOI: 10.14203/j.mev.2013.v4.51-56

Abstract

Quality of the diesel-electric train (KRDE) modified from the electric train (A and B types) which were used in three operating regions in the Indonesian Railway Company has been evaluated by analyzing the cause of the KRDE damages in terms of some aspects including: design, components quality, maintenance (method, finance, human resources), environment and way of operation. Based on the evaluation, it was found that the modification of the both types of KRDE provided a very low reliability and availability due to design and technical problems, as well as unoptimal maintenance. In KRDE type A, damage occurs in the cabling system, compressor, radiator fan system, and the braking system. While in type B, damage occurs in the traction motors, static inverter, and radiator fan. It is predicted that their life span can not reach the design life of 25 years, and even they are expected to be grounded. Many improvement is required to lengten their service life including: repair, modification, human resource competence, facilities, spare parts, maintenance and management.

Page 1 of 3 | Total Record : 24