cover
Contact Name
Dina Mariani
Contact Email
dinamariani@unimus.ac.id
Phone
+6285299398663
Journal Mail Official
mediaelektrika@unimus.ac.id
Editorial Address
Universitas Muhammadiyah Semarang FT-FMIPA Building, 7nd Floor. Department of Electrical Engineering Jl. Kedungmundu Raya No. 18, Kota Semarang, Prov. Jawa Tengah, Indonesia 50273 Phone: 085299398663 Email: mediaelektrika@unimus.ac.id
Location
Kota semarang,
Jawa tengah
INDONESIA
MEDIA ELEKTRIKA
ISSN : 19797451     EISSN : 2579972X     DOI : 10.26714/me.14.2.2021.62-75
Media Elektrika is an electrical engineering journal that gives concerns on sciences related to electrical engineering. It includes the following fields: Electrical power engineering Electronics Telecommunication Control Informatics and computer technology
Articles 5 Documents
Search results for , issue "Vol 11, No 2 (2018): MEDIA ELEKTRIKA" : 5 Documents clear
ANALISIS PENGARUH BEBAN PUNCAK FEEDER TERHADAP EFISIENSI TRANSFORMATOR 31,5 MVA DAN 60 MVA Arvian Widya Mukti
MEDIA ELEKTRIKA Vol 11, No 2 (2018): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (929.115 KB) | DOI: 10.26714/me.11.2.2018.52-64

Abstract

EnglishThe efficiency of a transformer is, among other things, determined by the magnitude of the load that increases from month to month as well as from year to year. Therefore we need a study on the optimization of transformer efficiency, in this case carried out on the substation of 150 KV Srondol Semarang, In the study can be determined the optimal transformer efficiency in accordance with the influence of peak load on the feeder. Efficiency often becomes a benchmark for transformer performance. The ideal transformer efficiency is when the power capacity of the transformer is equal to the power absorbed by the load, It is necessary to further analyze the factors affecting the efficiency and treatment or action changes to keep the transformer performance to be good and optimal. IndonesianEffisiensi suatu transformator antara lain ditentukan oleh besarnya beban yang meningkat baik dari bulan ke bulan maupun dari tahun ke tahun. Oleh karena itu diperlukan suatu studi mengenai optimalisasi efisiensi transformator, dalam hal ini dilaksanakan pada Gardu Induk 150 KV Srondol Semarang, pada studi tersebut dapat ditentukan effisiensi transformator yang optimal sesuai dengan pengaruh beban puncak pada feedernya. Efisiensi kerap kali menjadi suatu tolak ukur unjuk kerja transformator. Efisiensi transformator yang ideal adalah ketika kapasitas daya transformator sama dengan daya yang terserap oleh beban, maka perlu analisis lebih lanjut mengenai faktor – faktor yang mempengaruhi perubahan efisiensi dan treatment atau tindakan untuk menjaga kinerja transformator tersebut menjadi baik dan optimal.
PERANCANGAN MONITORING DAN KONTROL TEMPERATUR DAN KELEMBABAN UDARA RUANG KONTROL PANEL MENGUNAKAN RASPBERRY Pi 2 BERBASIS IoT Riki Sanaji; Rangga Dipta Azhari
MEDIA ELEKTRIKA Vol 11, No 2 (2018): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (908.585 KB) | DOI: 10.26714/me.11.2.2018.85-96

Abstract

Internet of Things (IoT) adalah hubungan objek fisik yang terhubung dengan elektronik, software, sensor, dan hubungan jaringan yang menjadikan objek–objek tersebut dapat saling mengumpulkan dan mengirim data. IoT memperbaharui sistem industri dengan sangat signifikan, konsep pengendalian dan pemonitoran yang disediakan oleh IoT sangat bermanfaat untuk meningkatkan efisiensi dunia monitoring, salah satunya adalah dalam pemonitoran dan pengendalian kondisi temperatur dan kelembaban udara ruang kontrol panel. Pengontrolan udara sangat penting untuk menjaga komponen – komponen kontrol panel. Mesin akan bekerja secara maksimal dan komponen–komponen kontrol akan lebih optimal saat mesin beroprasi juga saat mencapai beban yang sangat tinggi. Dengan konsep IoT, menggunakan perangkat monitoring dan kontrol temperature dapat memonitoring secara langsung dan dapat di akses dari perangkat lain. Data – data hasil pengukuran akan tersimpan pada data base yang dapat di gunakan untuk analisa udara di ruang kontrol panel. Data analisa digunakan untuk perawatan sistem pendingin juga memperbaharui sistem pendinginan ruang kontrol panel.
ANALISA SISTEM PENCAHAYAAN DAN PENGKONDISI UDARA GEDUNG RAJAWALI RSUP DR. KARIADI SEMARANG Catur Nofianto; Rizal Fajar Rahmawan
MEDIA ELEKTRIKA Vol 11, No 2 (2018): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (727.753 KB) | DOI: 10.26714/me.11.2.2018.75-84

Abstract

EnglishWith the research Rajawali Building energy audits at the General Hospital Center Kariadi doctor is expected to generate electrical energy consumption in the policy environment Rajawali Building. Electrical energy is supplied to the use of tools such as lighting systems, HVAC system (AC), and the utility system (pump). The intensity value of energy consumption for building Rajawali General Hospital Physicians Kariadi Semarang based on a calculation of the total recapitulation electricity consumption per building area last year was 98.69 kWh / m2 / year. Energy management systems in Rajawali Building General Hospital Physicians Kariadi Semarang already seen their energy saving measures in the building. Installation of energy metering has been done that will allow the monitoring system energy use. Doctors Hospital Kariadi Rajawali building using electrical energy in 2016 amounted to 1,826,775 kWh / year. The composition of the major energy users in the building occupied by the AC Eagles by 79%, the lighting is 11% and 10% pump.IndonesianDengan adanya penelitian audit energi di Gedung Rajawali Rumah Sakit Umum Pusat Dokter Kariadi ini diharapkan dapat menghasilkan kebijakan pemakaian energi listrik di lingkungan Gedung Rajawali. Energi listrik disuplai untuk penggunaan peralatan antara lain , sistem penerangan, sistem tata udara ( AC ), dan sistem utilitas ( pompa ). Nilai Intensitas konsumsi energi untuk Gedung Rajawali Rumah Sakit Umum Pusat Dokter Kariadi Semarang berdasarkan perhitungan dari total rekapitulasi pemakaian listrik per luas bangunan satu tahun terakhir adalah 98,69 kWh / m2 / Tahun. Sistem manajemen energi yang ada di Gedung Rajawali Rumah Sakit Umum Pusat Dokter Kariadi Semarang sudah terlihat adanya langkah-langkah penghematan energi khusus di gedung ini. Pemasangan metering energi sudah dilakukan sehingga akan memudahkan sistem monitoring penggunaan energi. Gedung Rajawali RSUP Dokter Kariadi menggunakan energi listrik pada tahun 2016 sebesar 1.826.775 kWh / tahun. Komposisi pengguna energi utama di Gedung Rajawali ditempati oleh AC sebesar 79 %, pencahayaan adalah 11% dan pompa 10 %.
PENGEMBANGAN SISTEM INFORMASI AKADEMIK USER FRIENDLY UNTUK SMA MUHAMMADIYAH KOTA TEGAL (SIATA) Luthfi Nur Hidayanti
MEDIA ELEKTRIKA Vol 11, No 2 (2018): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (634.979 KB) | DOI: 10.26714/me.11.2.2018.65-74

Abstract

EnglishAn Academic Information System of Senior High School (SMA) is called SIATA. The system is designed and made to make easy on data processing of a school. SIATA is made only for offline web or local host. The method on designing SIATA uses waterfall model, because it is flexible model. SIATA needs an alpha and beta trial testing to find the weakness and quality of the system before it is implemented as the running system. The result of the design is an academic information system, which is easy used by the user. The operating system is not difficult, so it is can be user friendly system. Indonesian Sistem Informasi Akademik SMA Muhata atau yang disebut SIATA, merupakan suatu sistem yang dirancang dan dibangun untuk mempermudah sekolah dalam proses pengolahan data akademik. Saat ini SIATA dibangun sebatas web offline atau localhost. Metode yang digunakan dalam perancangan SIATA ini menggunakan model waterfall karena sifatnya yang fleksibel. Sebelum SIATA diimplementasikan menjadi sistem yang berjalan akan dilakukan pengujian alpha dan pengujian beta guna menemukan kelemahan sistem dan menentukan kualitas sistem. Hasil dari perancangan ini adalah sebuah sistem informasi akademik yang mudah digunakan oleh user dan pengoperasiannya tidak rumit sehingga menjadi sistem yang user friendly.
ANALISA JARINGAN FTTH STO JOHAR KE MG SETOS BERDASARKAN TEKNOLOGI GPON DI PT. TELKOM AKSES DIGITAL LIFE REGIONAL IV JATENG DAN D.I.Y Mochamad Subchan Mauludin; Indah Rahmawati
MEDIA ELEKTRIKA Vol 11, No 2 (2018): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (371.687 KB) | DOI: 10.26714/me.11.2.2018.43-51

Abstract

Serat optik merupakan media transmisi yang dapat menyalurkan informasi dengan kapasitas besar dan teknologinya disebut Jaringan Lokal Akses Fiber. FTTH (Fiber To The Home). Analisa jaringan FFTH berteknologi GPON dengan parameter daya transmisi di Optical Line Terminal, daya receiver, redaman kabel serat optik, konektor, passive splitter, dan sambungan, jaringan FTTH  STO Johar ke MG Setos dilakukan dengan metode link power budget dan rise time budget. Pr sensitivitas uplink dan downlink  menunjukkan nilai rata-rata, yakni  -13,71997 dBm dan 13,55897 dBm sehingga margin daya yang didapatkan adalah 0,28003  dBm untuk uplink dan 0,44103  dBm untuk downlink. Sedangkan untuk rise time total sebesar 0,667 ns  untuk  downlink. Hasil dari perhitungan dan skema FTTH STO Johar ke MG Setos sesuai dengan standar di PT. Telkom.