cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
ganendra@batan.go.id
Editorial Address
Jl. Babarsari Kotak Pos 6101 ykbb, Yogyakarta 55281
Location
Kota adm. jakarta selatan,
Dki jakarta
INDONESIA
Ganendra: Majalah IPTEK Nuklir
ISSN : 14106957     EISSN : 25035029     DOI : https://doi.org/10.17146/gnd
Core Subject : Science, Education,
Jurnal Iptek Nuklir Ganendra merupakan jurnal ilmiah hasil litbang dalam bidang iptek nuklir, diterbitkan oleh Pusat Teknologi Akselerator dan Proses Bahan (PTAPB) - BATAN Yogyakarta. Frekuensi terbit dua kali setahun setiap bulan Januari dan Juli.
Arjuna Subject : -
Articles 6 Documents
Search results for , issue "Volume 20 Nomor 2 Juli 2017" : 6 Documents clear
PERBANDINGAN HASIL KONSTRUKSI TERHADAP HASIL SIMULASI DARI ISOKRONUS MAGNET SIKLOTRON DECY-13 Idrus Abdul Kudus, Taufik, Kurnia Wibowo, Fajar Sidik Permana
GANENDRA Majalah IPTEK Nuklir Volume 20 Nomor 2 Juli 2017
Publisher : Website

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (522.542 KB) | DOI: 10.17146/gnd.2017.20.2.3577

Abstract

Dalam siklotron, magnet merupakan komponen utama untuk menghasilkan lintasan partikel melingkar dan memfokuskan berkas partikel. Sebuah sistem magnet siklotron dengan kapasitas 13 MeV telah berhasil dibangun. Selanjutnya karakteristiknya dievaluasi dengan membandingkan nilai isokronus magnet yang dibangun terhadap hasil simulasi. Proses tersebut dilakukan melalui tahapan komisioning dan pemetaan medan magnet (untuk mengukur distribusi medan magnet dari setiap hill magnet dengan menggunakan sensor Tesla Meter dalam interval jarak pengambilan data 5 mm selama +9 jam). Dengan menggunakan arus koil maksimum 133 A dan menggunakan 2 (dua) hall probe hasil mapping medan magnet menghasilkan kurva medan rerata di atas medan isokronus dengan rentang kesalahan 0,3%. Akan tetapi, pada jari-jari kurang dari 8 cm medan rerata masih dibawah kurva isokronous. Oleh karena itu, perlu proses shimming dengan menambah ketebalan bump 0,5 mm pada area pusat dan mengurangi medan rerata pada jari-jari lebih dari 8 cm supaya mendekati kurva isokronous.
SUMBER ELEKTRON TIGA ELEKTRODA MENGGUNAKAN TABUNG PEMERCEPAT NEC UNTUK MBE-LATEKS 300kV/20 mA Darsono Darsono; Suprapto Suprapto; Taufik Taufik
GANENDRA Majalah IPTEK Nuklir Volume 20 Nomor 2 Juli 2017
Publisher : Website

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1154.302 KB) | DOI: 10.17146/gnd.2017.20.2.3638

Abstract

SUMBER ELEKTRON TIGA ELEKTRODA MENGGUNAKAN TABUNG AKSELERATOR NEC UNTUK MBE-LATEKS 300kV/20 mA. Pada makalah ini dilaporkan hasil disain, konstruksi, dan karakterisasi sumber elektron (SE) tiga elektroda untuk mesin berkas elektron (MBE) lateks dengan memanfaatkan tabung pemercepat buatan NEC (National Electric Coorporation) sebagai ruang dan elektroda sumber elektron. Metode yang digunakan dengan mendisain flange untuk menempatkan filamen, katoda Pierce, dan anoda pemfokus yang terisolasi dengan katoda, kemudian flange ini dimuatkan pada tabung pemercepat yang telah dilepas 2 elektrodanya sehingga terbentuk struktur sumber elektron 3 elektroda jenis Pierce. Bentuk lintasan berkas elektron pada tabung pemercepat disimulasi menggunakan program OPERA-3D untuk variasi parameter posisi filamen relatif terhadap ujung lubang katoda Pierce 3; 1,5; -1,5; dan -2,5 mm menggunakan 1 tabung pemercepat. Dilanjutkan simulasi untuk beda tegangan katoda dan anoda pemfokus 5, 10, dan 15 kV menggunakan 2 tabung pemercepat. Selanjutnya dilakukan konstruksi dan karakterisasi profil dan arus berkas elektron keluarannya. Hasil penelitian menunjukkan bahwa pada posisi filamen -2,5 mm menghasilkan lintasan berkas elektron paling sedikit divergen dan merambat sejajar pada sumbu aksial 2 tabung pemercepat pada beda tegangan katoda dan anoda pemfokus 15 kV.  Profil  berkas elektron sangat ditentukan oleh tegangan anoda pemfokus. Besarnya keluaran arus berkas elektron sangat ditentukan oleh tegangan anoda ekstraksi dengan hasil terbesar 50 mA. SE yang dibuat ini memenuhi spesifikasi yang dibutuhkan untuk MBE lateks.
SURFACE MODIFICATION OF CHEMICAL VAPOR DEPOSITION (CVD) DIAMOND FILM/SI(111) BY IMPLANTATION WITH Fe + B IONS IN CONJUNCTION WITH THEIR MAGNETIC PROPERTIES Setyo Purwanto; A. Dimyati; R. Iskandar; Wisnu A.A; Tjipto S
GANENDRA Majalah IPTEK Nuklir Volume 20 Nomor 2 Juli 2017
Publisher : Website

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (677.034 KB) | DOI: 10.17146/gnd.2017.20.2.3281

Abstract

Surface Modification of Chemical Vapor Deposition (CVD) Diamond Film/Si(111)  by Implantation with Fe+B ions In Conjunction with their  Magnetic Properties. Surfcace modification of CVD manufactured diamond films on Si(111) substrate has been performed by means of Fe+B ion implantation followed by Argon ion gas sputtering with acceleration energy 20 keV and ion dose 1x1015  and 1x1016 ions cm-2. Scanning Transmission Electron Microscope (STEM) imaging shows the formation of amorphous carbon layer on top of the diamond film with thickness ca. 100 nm on the implanted sample and ca. 20 nm on the sample without implantion. The morphology and magnetic property of the films surface were characterized by Atomic and Magnetic Force Microscopy (AFM/MFM). The Electron Energy Loss Spectroscopy EELS analysis has revealed amount of Boron atoms distributed homogenously inside the carbon amorphous layer on both samples which is in close agreement to the result of Raman Spectroscopy showing the changes of the Raman spectrum due to implantation. The magnetic properties of the samples after Fe+B ion implantion were additionally investigated by means of Vibrating Sample Magnetometer (VSM). By increasing ion doses at constant energy 20 keV, the magnetoresistance property decreased from +45% on the sample implanted with dose 1x1015 to +8% on the sample implanted with dose 1x1016 ions cm-2.
PENENTUAN MASSA TEREROSI UNTUK BERBAGAI MATERIAL KATODA IGNITOR Lely Susita R.M; Anjar Anggraini; Ihwanul Aziz
GANENDRA Majalah IPTEK Nuklir Volume 20 Nomor 2 Juli 2017
Publisher : Website

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (641.803 KB) | DOI: 10.17146/gnd.2017.20.2.3034

Abstract

ABSTRAKPENENTUAN MASSA TEREROSI UNTUK BERBAGAI MATERIAL KATODA IGNITOR. Sistem elektroda ignitor yang berfungsi menginisiasi lucutan plasma terdiri dari dua buah elektroda ignitor yang dilengkapi dengan satu unit sistem catudaya lucutan ignitor (Ignitor Discharge Power Supply) dengan 2 trafo flyback, dimana inti ferit flyback masing-masing berdiameter 1,3 cm dan 1,5 cm sehingga diperoleh arus spot plasma yang berbeda untuk kedua sistem elektroda ignitor.  Arus spot plasma tergantung pada jenis material katoda. Semakin besar arus menuju katoda maka semakin besar spot plasma yang dihasilkan sehingga semakin besar pula material katoda yang tererosi.  Dalam penelitian ini dilakukan uji fungsi sistem elektroda ignitor, dan dari hasil uji fungsi dapat ditentukan besarnya massa dan partikel material katoda ignitor yang tererosi untuk menentukan umur katoda akibat hilangnya bahan di permukaan katoda setelah terbentuk spot plasma.  Hasil pengujian spot plasma pada permukaan katoda ignitor menggunakan material Mg, diperoleh arus spot plasma 13 A dan lebar pulsa 38 µdet, sedangkan untuk material Ag, Al, Cd dan Cu masing-masing diperoleh arus spot plasma 14,32 A, 12,34 A, 12,56 A dan 10,58 A lebar pulsa 22 µdet, 39 µdet, 38 µdet, dan 34 µdet.  Material katoda yang paling baik untuk sistem elektroda ignitor adalah magnesium karena mempunyai laju erosi γ paling rendah (11,7 µg/C) sehingga tidak mudah tererosi dan rusak.  Dari hasil pengujian spot plasma diperoleh  massa katoda tererosi untuk material Mg yang paling rendah yaitu 5,78 nano gram dan katoda akan berkurang sepanjang 11,75 μm, sedangkan massa katoda tererosi paling tinggi adalah Cd (laju erosi 43,9 µg/C) sebesar 20,95 nano gram, dimana katoda akan berkurang sepanjang 85,67 μm 
THERMODYNAMICS ANALYSES ON REGENERATIVE STEAM CYCLE WITH TWO TANKS FOR HTGR-10 CONCEPT Sri Sudadiyo; Geni Rina Sunaryo
GANENDRA Majalah IPTEK Nuklir Volume 20 Nomor 2 Juli 2017
Publisher : Website

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1116.723 KB) | DOI: 10.17146/gnd.2017.20.2.3302

Abstract

In this work, steam cycle from a nuclear power plant is explored in order to increase efficiency and electric power output. A thermal source in the form of a HTGR-10 concept is considered. The power conversion unit of HTGR-10 consists of steam generator, turbine, condenser, pump, and connecting pipes. Helium is used as the core coolant and the working fluid for power conversion unit is water/steam. The proposed thermodynamic process modification has been evaluated for regenerative steam power cycle of this reactor. The scope of study covered regenerative steam cycle with two tanks including feed water tank and intermediate feed water tank. The evaluation analyzes the effect of pressure, efficiencies of turbine and pumps, and tanks against thermal efficiency. The Cycle-Tempo software is used to simulate and optimized this effect on steam cycle based on HTGR-10. The results indicate improvements of as much as 2.65 % in thermal efficiency and 0.271 MWe in electric power.
NEUTRON RESPONSE FUNCTION OF BONNER SPHERE SPECTROMETER WITH 6LiI(Eu) DETECTOR Rasito Tursinah; Bunawas Bunawas; Jungho Kim
GANENDRA Majalah IPTEK Nuklir Volume 20 Nomor 2 Juli 2017
Publisher : Website

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (688.18 KB) | DOI: 10.17146/gnd.2017.20.2.3319

Abstract

The detector response function was needed to measure the neutron fluence based on the count rates from Bonner Sphere Spectrometer (BSS). The determination of response function of a BSS with 6LiI(Eu) detector has been performed using Monte Carlo MCNPX code. This calculation was performed for BSS using scintillation detector of 4 mm × 4 mm 6LiI(Eu) which is placed at the center of a set of polyethylene spheres i.e bare, 2", 3", 5", 8", 10", and 12" diameters. The BSS response functions were obtained for neutron energy of 1x10-9 MeV - 1x102  MeV in 111 energy bins and each value has an uncertainty less or equal to 2 %. The response function were compared with two response functions reported in the literature i.e IAEA document in Technical Reports Series 403 (TRS-403) and the calculation from Vega-Carrillo, et al. Also validated with measurement 252Cf neutron spectra, that shown the simulated BSS spectra were quite close to the experimental measured with a differrence of 3%.

Page 1 of 1 | Total Record : 6