cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kota adm. jakarta selatan,
Dki jakarta
INDONESIA
Widyanuklida
ISSN : -     EISSN : -     DOI : -
Core Subject : Science,
Jurnal Widyanuklida adalah majalah ilmiah pendidikan dan pelatihan, penelitian dan pengembangan sains dan teknologi nuklir serta bidang yang berkaitan, diterbitkan oleh Pusat Pendidikan dan Pelatihan (Pusdiklat), Badan Tenaga Nuklir Nasional (BATAN).
Arjuna Subject : -
Articles 5 Documents
Search results for , issue "Widyanuklida, Volume 12 Nomor 1, November 2012" : 5 Documents clear
Analisis Butir dan Pembuatan Bank Soal Endra Susila
Widyanuklida Widyanuklida, Volume 12 Nomor 1, November 2012
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (5627.735 KB)

Abstract

ABSTRAK Untuk mengetahui soal ujian yang baik atau bermutu dilakukan analisis butir soal dan soal yang baik dapat dimasukkan ke dalam bank soal. Analisis menggunakan metode kualitatif dan kuantitatif terhadap sampel 5 buah soal ujian materi Umum (General) pada pelatihan radiografi Level 1 di Pusdiklat BATAN tanggal 9 — 23 Februari 2009. Sampel soal dilihat kesesuaiannya terhadap aspek materi, konstruksi, bahasa/budaya (kualitatif) dan hasil pengolahan data empirik butir soal tersebut (kuantitatif). Berdasarkan analisis kualitatif soal nomor 30 sesuai dengan semua aspek, sedangkan soal nomor 21, 26, 30,31 dan 36 belum sesuai dengan ketiga aspek analisis kualitatif. Untuk hasil analisis kuantitatif soal direvisi nomor: 21, soal baik nomor 26 dan 36, dan soal didrop (dibuang) nomor: 30 dan 31 didrop. Dari hasil analisis kualitatif dan kuantitatif dapat disimpulkan bahwa soal ujian belum baik sehingga belum dapat dimasukkan ke dalam bank soal.   ABSTRACT To find a good examination questions, has been done an analysis of questions and from the results, the good questions will be incorporated into the question bank. Analysis was performed using qualitative and quantitative methods against 5 questions from the General examination of Radiography Level 1 Training Course, which be held on February 9 to 23, 2009. The questions were reviewed for the compliance to the aspects of materials, construction, language / culture (qualitative) and the processing of the empirical data (quantitative). Based on the qualitative analysis, questions no. 30 fulfilled all aspects to be reviewed, and question number 21, 26, 3031, and 36 did not fulfilled the third aspect of qualitative analysis. From the qualitative and quantitative analysis results, it can be concluded that the questions were not good enough to be put into the question bank.  
Pengaruh Perubahan Energi Radiasi Terhadap Respon Energi Surveymeter Anda Sanusi
Widyanuklida Widyanuklida, Volume 12 Nomor 1, November 2012
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (3280.027 KB)

Abstract

ABSTRAK Telah dilakukan suatu percobaan atau pengujian untuk mengamati respon energi surveymeter terhadap perubahan energi radiasi. Percobaan dilakukan terhadap 12 buah surveymeter berlainan merk, model dan tipe detektor, dengan cara menempatkan surveymeter tersebut pada medan radiasi radiasi gamma dan Sinar-X yang dihasilkan dari Cs-137, C0-60 dan pesawat sinar-X merk PANTAK HF420. Respon energi surveymeter (R) diamati dengan membandingkan antara laju dosis ekivalen yang terukur surveymeter (M) dengan ambient dose equivalent (H*10) yang dipancarkan oleh sumber radiasi. Dari hasil percobaan terlihat bahwa surveymeter dengan detektor Ionization Chamber (IC) mempunyai rentang respon energi yang lebih panjang dibanding dengan surveymeter GM maupun Sintilasi. Secara umum, pada energi radiasi yang rendah sensitivitas surveymeter GM lebih baik dibanding surveymeter IC.   ABSTRACT The experiment to investigate of energy response of the Gamma ray surveymeters have been performed. The experiments were conducted by using Ionization Chamber, Scintillation and GM surveymeter which consist of 12 models of surveymeters. In the experiments, the surveymeters were irradiated by a gamma sources, such as Cs-137, Co-60, and X-rays of PANTAK HF420 X-ray machine. The experiment result shows that IC type surveymeter has a maximum response at the longest of range of energy. In general, at low energy the sensitivity of GM type and Scintillation is better than those of IC type.  
Penentuan Waktu Penyinaran Radiografi Ir-192 Menggunakan Persamaan Dosis Radiasi Suparno Suparno; Anda Sanusi
Widyanuklida Widyanuklida, Volume 12 Nomor 1, November 2012
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (2432.024 KB)

Abstract

ABSTRAK Penyinaran radiografi dilakukan dengan sumber radiasi Ir-192 dan sistem film yang terdiri dari film AGFA D7, skrin lembaran timbal 0,125 mm dan kaset lentur berbahan plastik berwarna hitam. Waktu penyinaran ditentukan dengan menggunakan persamaan dosis radiasi. Perhitungan didasarkan pada dosis radiasi untuk mendapatkan densitas radiograf 2 yang diperoleh dari kurva karakteristik hasil percobaan, yaitu sebesar 1400 mRem, dan laju dosis radiasi yang dihitung berdasarkan persamaan yang diturunkan dari hukum Lambert. Radiografi dilakukan pada sebuah stepwedge yang terbuat dari bahan carbon steel yang memiliki step dengan 10 ketebalan. Hasil radiografi masing-masing step sasaran dari stepwedge memiliki densitas radiografi antara 2,24 sampai 2,65.   ABSTRACT Radiographic exposure of Ir-192 radiation source has been performed on a film sistem consisting of AGFA D7 films, 0,125 mm lead foil screens and black plastic of flexible cassettes. Exposure time is determined using the equation of radiation dose. The exposure time calculation is based on the radiation dose to get the radiograph density of 2 derived from characteristic curves resulting from experimental which indicate the value of 1400 mRem, and radiation dose rate is calculated based on equations derived from the law of Lambert. Radiography was performed on a stepwedge made of carbon steel having 10 thickness of step. Radiograph results of each target step has a radiographic density between 2.24 to 2.65.  
Uji Visual dan Ketahanan Proyeksi Pada Peralatan Radiografi Gamma Industri Jenis Portabel B.Y. Eko Budi Jumpeno
Widyanuklida Widyanuklida, Volume 12 Nomor 1, November 2012
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (5797.749 KB)

Abstract

ABSTRAK Uji visual dan ketahanan proyeksi pada kamera gamma industri portabel jenis Tech Ops 660 A/2190, Delta 880 / D5549, Amertes 660B/B1822, dan Sentinel 660 A/A 1357 serta 4 perangkat kendali sumber telah dilakukan. Metode pengujian yang diterapkan mengacu pada SNI ISO 3999:2008. Pengujian ini dilakukan untuk memastikan dan menjamin bahwa peralatan radiografi yang digunakan memenuhi persyaratan keselamatan berkaitan dengan kondisi visual dan mekanik sehingga layak dioperasikan dengan aman. Pelaksanaan uji visual dilakukan dengan pemeriksaan visual pada kamera gamma dan perangkat kendali sumber. Sedangkan pelaksanaan uji ketahanan proyeksi dilakukan dengan memasang perangkat radiografi gamma dan alat pelengkung 90° pada selongsong kabel kendali dan pelengkung 45° pada selongsong proyeksi. Hasil uji menunjukkan bahwa kamera gamma tipe Tech Ops 660 A dan Delta 880 lolos uji, sedangkan tipe Amertes 660 B dan Sentinel 660 A tidak lolos uji. Sedangkan pada uji visual dan ketahanan proyeksi 4 perangkat kendali sumber menunjukkan bahwa hanya 2 yaitu perangkat kendali sumber (Tech Ops 660 A) dan perangkat kendali sumber (Sentinel 660 A) yang lolos uji.   ABSTRACT Visual and projection endurance test on portable industrial gamma cameras type AI2190 Tech Ops 660, Delta 8801 D5549, Amertes 660BIB1822, and Sentinel 660 A 1A 1357 as well as 4 source control devices has been done. Tesing methods are applied refer to SNI ISO 3999:2008. The tes is performed to ensure and guarantee that the use of portable radiography equipments meet the safety requirements relating to visual and mechanical condition so it is worth operated safely. Implementation of visual test was performed by visual examination of the gamma cameras and the source control devices. Meanwhile, projection endurance test is done by installing gamma radiography devices and 90° and 45° bending equipment to cable housing and source guide tube respectively. The result of the test shows that the gamma cameras type A Tech Ops 660 and Delta 880 pass the test, whereas type Amertes 660 B and Sentinel 660 A not pass the test. While, the test of 4 projection control devices indicate that only two control devices, namely the source control device (Tech Ops 660 A) and the source control device (Sentinel 660 A) that pass the test.  
Evaluasi Kualitas Soal Ujian Pelatihan Radiografi Bagiyono Bagiyono
Widyanuklida Widyanuklida, Volume 12 Nomor 1, November 2012
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (3805.783 KB)

Abstract

ABSTRAK Soal ujian yang berkualitas adalah soal yang memenuhi kaidah-kaidah tertentu, sehingga mampu mengevaluasi secara akurat pencapaian tujuan pembelajaran yang telah ditentukan. Untuk mengetahui kualitas dari soal ujian pelatihan radiografi di Pusdiklat, telah dilakukan penelitian terhadap soal yang telah diujikan. Penelitian dilakukan dengan cara melakukan analisis setiap soal dikaitkan dengan kaidah-kaidah pembuatan soal pilihan berganda yang efektif. Obyek dari penelitian ini adalah soal-soal ujian materi general yang diberikan pada pelatihan Radiografi Level 1 dan Level 2 pada tahun 2010 - 2012. Analisis yang dilakukan dibatasi hanya mengevaluasi dari segi format, struktur dan tata bahasa. Dari hasil analisis teramati bahwa 95% soal yang diberikan sudah memenuhi kaidah pembuatan soal pilihan berganda yang efektif, sedangkan sisanya masih memerlukan revisi pada beberapa aspek yang dievaluasi. Berdasarkan hasil penelitian dapat disimpulkan bahwa sebagian besar soal ujian pelatihan Radiografi yang diselenggarakan di Pusdiklat BATAN dapat dikategorikan sebagai soal yang berkualitas dari segi format, struktur dan tata bahasa.   ABSTRACT The good quality questions are the questions which have the certain format as well as structure and grammar, so that they can measure accurately the achievement of the designed learning objectives. To evaluate the quality of the examination questions, has been conducted a research on the questions in the Radiographic examination. The study was conducted by analysing the individual question and then comparing to the rules on writing an effective multiple-choice question. The object of this study are the Examination Questions that has been delivered in the Radiography Level 1and Level 2 training courses in 2010 to 2012. The analysis was conducted by reviewing the format as well as structure, and grammar. From the analysis performed it was observed that 95% of the given question has fulfilled the rules of writing an effective multiple-choice question, while the rest need revisions on some aspects to be evaluated. Based on these results it can be concluded that most of the examination question in the radiographic training course held in Pusdiklat BATAN can be categorized as the good quality questions based on format, structure and grammar.  

Page 1 of 1 | Total Record : 5