cover
Contact Name
Wahyudi
Contact Email
transient@elektro.undip.ac.id
Phone
+628122823417
Journal Mail Official
transient@elektro.undip.ac.id
Editorial Address
Jl. Prof. Sudharto, SH – Tembalang, Semarang Jawa Tengah 50275
Location
Kota semarang,
Jawa tengah
INDONESIA
TRANSIENT: Jurnal Ilmiah Teknik Elektro
Published by Universitas Diponegoro
ISSN : -     EISSN : 26850206     DOI : -
Core Subject : Engineering,
TRANSIENT: Jurnal Ilmiah Teknik Elektro (e-ISSN:2685-0206) diterbitkan oleh Departemen Teknik Elektro Universitas Diponegoro. Pertama kali terbit pada tahun 2012. TRANSIENT: Jurnal Ilmiah Teknik Elektro menerima artikel ilmiah dari pakar dan peneliti baik dari industri maupun akademisiTRANSIENT: Jurnal Ilmiah Teknik Elektro menerbitkan makalah ilmiah berbahasa Indonesia untuk bidang Teknik Elektro meliputi Ketenagaan, Telekomunikasi, Elektronika, Sistem Kendali, Instrumentasi, Biomedika, Komputer dan Teknologi Informasi, serta topik-topik yang terkait. Jadwal penerbitan setiap tiga bulan sekali (Maret, Juni, September dan Desember). Artikel yang terbit akan diberikan nomer identifier unik (DOI/Digital Object Identifier) dan tersedia serta bebas diunduh dari website ini. Penulis tidak dipungut biaya baik untuk pengiriman artikel maupun pemrosesan artikel. Transient telah terindeks di Google Scholar, Garuda, Dimensions.
Articles 30 Documents
Search results for , issue "TRANSIENT, VOL. 4, NO. 1, MARET 2015" : 30 Documents clear
PERANCANGAN INVERTER HALF BRIDGE SEBAGAI CATU DAYA TEGANGAN TINGGI AC FREKUENSI TINGGI DENGAN BEBAN KUMPARAN TESLA DAN DIELECTRIC BARRIER DISCHARGE CHAMBER S, Reza Heryanto; Facta, Mochammad; Riyadi, Munawar Agus
Transient: Jurnal Ilmiah Teknik Elektro TRANSIENT, VOL. 4, NO. 1, MARET 2015
Publisher : Universitas Diponegoro

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (806.38 KB) | DOI: 10.14710/transient.4.1.114-121

Abstract

Abstrak Aplikasi kumparan tesla merupakan pembangkitan tegangan tinggi dengan frekuensi tinggi. Kumparan tesla secara konvensional menggunakan spark gap dalam pembangkitannya yang membutuhkan peralatan yang berdimensi besar. Dengan berkembangnya rangkaian semikonduktor maka rangkaian semikonduktor digunakan untuk pembangkitan kumparan tesla salah satunya menggunakan inverter. Kumparan tesla dengan menggunakan inverter sebagai catu daya sudah pernah dilakukan salah satunya menggunakan inverter jembatan penuh tetapi masih sedikit terdapat kekurangan yaitu penggunaan komponen semikonduktor yang tertalu banyak. Berdasarkan hal diatas penelitian ini dirancang suatu inverter untuk catu daya kumparan tesla menggunakan inverter half bridge.  Inverter half bridge  yang dirancang menggunakan MOSFET sebagai saklar elektronik dan IC TL494 sebagai osilator frekuensi pengontrol pemicuan MOSFET. Rancangan inverter yang dilakukan meliputi perancangan trafo pulsa sebagai isolator listrik antara rangkaian kontrol dan daya. Pengujian dilakukan dengan beban rangkaian resonansi kumparan Tesla yang dihubungkan pada beban ozon chamber yang membutukan frekuensi tinggi dan tegangan keluaran 2-3kv peak to peak. Pengujian ini untuk mengetahui pengaruh frekuensi terhadap tegangan disisi beban. Kumparan Tesla memiliki perbandingan 11 : 2020 lilitan. Pengujian dilakukan pada rentang  frekuensi 60 kHz dan 70 kHz. Frekuensi 65  kHz merupakan frekuensi resonan yang menghasilkan tegangan yang tertinggi yaitu sebesar 2,6kV. Kata Kunci: kumparan tesla, frekuensi tinggi, inverter, half bridge, ozon chamber.  Abstract Tesla coil application is the generation of high voltage with high frequency. Tesla coil conventionally using a spark gap in a generation that require large equipment dimensions. With the development of the semiconductor circuit semiconductor circuit used for the generation of one tesla coil using an inverter. Tesla coil by using an inverter as the power supply has been made one of them using a full-bridge inverter but still a bit of a shortage of semiconductor components that use too much. Based on this research designed an inverter to the power supply using a tesla coil half-bridge inverter. Half bridge inverter designed using MOSFET as electronic switches and IC TL494 as the oscillator frequency MOSFET controller triggers. The design of the inverter was conducted on the design of the pulse transformer as an electrical insulator between the control circuit and power. Testing is done with a Tesla coil load resonant circuit connected to the load ozone chamber that require high frequency and output voltage 2-3kv peak to peak. This test is to determine the effect of frequency on the load side voltage. Tesla coil has a ratio of 11: 2020 windings. Tests carried out in the frequency range of 60 kHz and 70 kHz. Frequency of 65 kHz is a resonant frequency that produces the highest voltage that is equal to 2,6kV. Keyword : tesla coil, high frekuensi, inverter, Half bridge, ozon chamber.
WATERMARKING CITRA DIGITAL PADA RUANG WARNA YUV DENGAN KOMBINASI METODE DISCRETE WAVELET TRANSFORM (DWT) DAN SINGULAR VALUE DECOMPOSITION (SVD) Antonio Christian Simanjuntak; Achmad Hidayatno; Munawar Agus Riyadi
Transient: Jurnal Ilmiah Teknik Elektro TRANSIENT, VOL. 4, NO. 1, MARET 2015
Publisher : Universitas Diponegoro

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (556.558 KB) | DOI: 10.14710/transient.v4i1.44-50

Abstract

Abstrak Dalam era teknologi informasi dan komputer saat ini, informasi dalam bentuk digital dapat tersebar dengan begitu cepat. Informasi dalam bentuk digital memiliki sifat yang mudah untuk diubah dan dimodifikasi, hal ini menyebabkan banyak terjadinya penyalahgunaan hak cipta. Seseorang yang telah mendapatkan produk digital dapat mengklaim bahwa produk tersebut adalah hasil karyanya. Salah satu cara untuk melindungi hak cipta produk digital tersebut adalah dengan menggunakan watermark. Watermark merupakan salah satu solusi untuk melindungi hak cipta terhadap citra digital yang diciptakan. Dengan diterapkannya watermarking ini maka hak cipta citra digital yang dihasilkan akan terlindungi dengan cara menyisipkan informasi tambahan seperti informasi pemilik, keaslian dalam bentuk teks, citra, audio, ataupun video ke dalam citra digital tersebut tanpa merusak citra asli. Discrete Wavelet Transform (DWT) dan Singular Value Decomposition (SVD) merupakan salah satu metode yang banyak digunakan dalam teknik watermarking dalam domain transformasi. Dalam Penelitian ini DWT digunakan untuk mentransformasi citra digital, sementara SVD digunakan sebagai proses penyisipan dan ekstraksi watermark. Pada pengujian Penelitian ini didapatkan nilai PSNR di atas 20 - 40 dB dengan variasi nilai alfa 0,1 - 1 pada komponen Y, U dan V. Sementara dalam kondisi tanpa serangan pada pengujian ekstraksi didapatkan nilai NC tidak kurang dari 0,8. Hal ini menunjukkan bahwa watermarking dengan menggunakan metode kombinasi DWT dan SVD menunjukkan kinerja yang cukup baik, meskipun terdapat informasi pada citra watermark hasil ekstraksi yang tidak sempurna.              Kata kunci: Watermarking, Discrete Wavelet Transform, Singular Value Decomposition, PSNR, NC  Abstract In the era of information technology and computer today, information in digital form can spread so quickly. Information in digital form has characteristic that are easy to be changed and modified, this causes a lot of the abuse of copyright. A person who has obtained a digital product can claim that the product is a result of his work. One way to protect the copyright of digital products is to use watermark. Watermark is one of the solutions to protect the copyright of the digital image that has been produced. With this implementation, the copyright of the digital images will be protected by inserting additional information such as owner information, authenticity in the form of text, image, audio, or video into digital images without damaging the original image. Discrete Wavelet Transform (DWT) and Singular Value Decomposition (SVD) is one method that is widely used in the transform domain watermarking techniques. In this research DWT is used to transform the digital image, while SVD is used as the watermark insertion and extraction. In this research testing PSNR values obtained above 20 to 40 dB with a variation of alpha values from 0.1 to 1 in the component Y, U and V. While the extraction testing without attacks, NC values obtained not less than 0.8. This indicates that a combination of watermarking using DWT and SVD method shows good performance, although there is information on the extracted watermark image which not perfect. Keywords: Watermarking, Discrete Wavelet Transform, Singular Value Decomposition, PSNR, NC
ANALISIS KERJA INVERTER JEMBATAN PENUH DENGAN RANGKAIAN PASIF LC BEBAN PARALEL Isnain, Taruna Miftah; Facta, Mochammad; Karnoto, Karnoto
Transient: Jurnal Ilmiah Teknik Elektro TRANSIENT, VOL. 4, NO. 1, MARET 2015
Publisher : Universitas Diponegoro

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (538.771 KB) | DOI: 10.14710/transient.4.1.147-154

Abstract

Abstrak Rangkaian inverter adalah jenis konverter rangkaian elektronika daya. Fungsi rangkaian inverter adalah perubah tegangan dari DC ke AC. Dalam inverter konvensional, transformator di butuhkan untuk menaikkan tegangan mencapai nilai yang diperlukan. Namun, transformator memiliki beberapa kelemahan yaitu rugi tembaga, hysterisis, efek kulit dan arus eddy.Untuk mengatasi kekurangan transformator, tugas akhir ini mengusulkan penggunaan rangkaian LC beban paralel untuk mengganti fungsi transformator dan menaikkan tegangan. Untuk mewujudkan tujuan di atas maka dirancang catu daya  inverter jembatan penuh frekuensi tinggi dengan rangkaian LC beban paralel. Inverter jembatan penuh frekuensi tinggi menggunakan MOSFET yang dikendalikan oleh IC TL494. Tegangan AC disearahkan menggunakan rangkaian penyearah jembatan penuh. Hasil penyearahan yaitu tegangan DC diubah menjadi tegangan AC frekuensi tinggi melalui inverter. Inverter akan menyuplai rangkaian pasif LC beban paralel. Semakin tinggi tegangan yang didapatkan pada keluaran inverter dikarenakan faktor penguatan rangkaian LC beban paralel. Rangkaian membutuhkan beban resistif murni untuk mengamati kenaikan tegangan. Hasil pengujian menunjukkan inverter jembatan penuh  dioperasikan pada frekuensi resonansinya 35kHz, duty cycle 90%  dengan tegangan masukan  35,35 Volt DC alat ini mampu menghasilkan tegangan keluaran 186,3 Volt AC. Lampu LED yang dicatu dengan tegangan 186,3 Volt ini mampu menghasilkan intensitas penerangan 1969 Lux. Efisiensi  inverter dengan rangkaian  LC beban paralel  96,75%. Kata Kunci: transformator, rangkaian LC beban paralel, inverter jembatan penuh  Abstract Inverter circuit is one kind of converter in power electronics circuit. Function of inverter circuit is  voltage converter from DC to AC. In conventional inverter, transformer needed to increase voltage. However, transformer i.e. losses skin effect and eddy current. To overcome the lack of transformator, this final project use of parallel load LC  circuit to replace the transformer and step up voltage. To realize the purpose  then power supply is designed  full bridge inverter with parallel load LC circuit. High frequency full bridge inverter uses MOSFET controlled by IC TL494. The AC voltage from the grid is rectified by full bridge rectifier circuit. Result of rectifier i.e. dc voltage is  converted into  AC voltage. Inverter supplied parallel load LC circuit. Higher voltage at inverter output is obtainned due to amplification factor inside parallel load LC passive circuit. The circuit feeds resistive load to observe voltage gain.The result, that the full bridge inverter was succesfully operated at resonance frequency, 35kHz, duty cycle 90% with input voltage 35,35 Volt DC. At this condition the converter could produce 186,3 Volt AC. LED lamp which supplied by this 186,3 Volt produce light intensity 1969 lux. Efficiency inverter with parallel load LC  circuit is 96,75%. Keyword : transformator, parallel load LC passive circuit, full bridge inverter
SOFT STARTING DAN PENGATURAN KECEPATAN MOTOR INDUKSI TIGA FASA MENGGUNAKAN MICROMASTER 440 PADA APLIKASI PENGGERAK BLADE MESIN EKSTRAKSI BIJI KAPUK Haq, M. Azamul Faiz Dinul; Facta, Mochammad; Sukmadi, Tedjo
Transient: Jurnal Ilmiah Teknik Elektro TRANSIENT, VOL. 4, NO. 1, MARET 2015
Publisher : Universitas Diponegoro

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (780.688 KB) | DOI: 10.14710/transient.4.1.80-88

Abstract

Abstrak Sistem kontrol untuk pengendali otomatis perangkat-perangkat mesin diindustri awalnya dirancang menggunakan kontaktor dan relai. Namun demikian sistem kontrol dengan rangkaian  tersebut menjadi kurang efektif karena untuk melakukan modifikasi sistem memerlukan biaya yang besar serta tingkat kerumitan kerja yang tinggi. Dalam penelitian ini dilakukan perancangan dan pengoperasian PLC dengan tegangan catu daya arus searah 24 Volt. PLC berfungsi mengaktifkan VSD micromaster 440 untuk mengatur arah putaran dan kecepatan motor induksi. Berdasarkan pengujian yang dilakukan, motor tidak berbeban, maka nilai arus, tegangan dan kecepatannya berubah mengikuti setting frekuensi sesuai dengan nilai yang ditetapkan dalam VSD. Dalam pengujian motor kondisi berbeban menghasilkan lonjakan arus ketika pengaturan kecepatan ditetapkan pada frekuensi 5 sampai 15 Hz. Hal ini diakibatkan karena torsi pembebanan yang besar saat mengolah biji kapuk. Dalam penelitian ini kecepatan pengolahan biji kapuk juga ditingkatkan dengan pemakaian puli sehingga kecepatan mesin naik 1,6 kali kecepatan motor penggerak. Pengujian fungsi pengereman dengan injeksi daya arus searah di VSD micromaster 440 menunjukan bahwa semakin besar arus pengereman maka waktu pengereman semakin cepat.  di VSD micromaster selanjutnya disetting prosentase arus 30% menghasilkan arus injeksi 0,3 (Ampere)  dan waktu pengereman  2,2 (detik). Saat setting prosentase arus 60%, pengereman menunjukan teori yang sama. Kata kunci : motor induksi tiga fasa, PLC, Variabel Speed Drive  Abstrract In the beginning of industry world, control system for automatic devices controller designed using contactor and relay. However, this control system tends to not effective in terms of system modification which needs big budget and high complicated works of devices. In this research, the design and PLC operation are done with the help of DC voltage power supply 24 Volt. PLC functions to activate a 440 micromaster VSD in order to manage the direction of its rotation and inductive motor velocity. According to the result test which using the unloaded motor, so that the current value, voltage and velocity change following the frequency setting and agree with the number which is given on the VSD. At the loaded motor test, it results a significant current once the velocity is set on the frequency of 5-15 Hz. These are caused by a numerous loaded torsion (torsi pembebanan yang besar) when processing the cotton plant. In this research, velocity of its processing device is enhanced by the use of (puli) as well. Hence, the velocity of machine raises 1,6 times of motor velocity. Moreover, the test of breaking function with DC injection in 440 micromaster VSD shows that the bigger breaking current, the faster breaking time. Furthermore, once VSD micromaster is set up on current precentage of 30%, it resulted 0,3 (Ampere) of injection current and 2,2 s of breaking time. When the current precentage raised up to 60%, the breaking time shows the same theory as mentioned before. Keywords: 3-phase inductive motor, PLC, Variable Speed Drive.
APLIKASI KONVERTER JENIS PUSH-PULL DENGAN RELAI PEMUTUS OTOMATIS SEBAGAI PENGISI AKUMULATOR N, Agustinus Danu; Facta, Mochammad; Nugroho, Agung
Transient: Jurnal Ilmiah Teknik Elektro TRANSIENT, VOL. 4, NO. 1, MARET 2015
Publisher : Universitas Diponegoro

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (972.419 KB) | DOI: 10.14710/transient.4.1.17-24

Abstract

Abstrak Akumulator merupakan sumber energi alternatif yang penting dalam media penyimpanan energi. Seringkali akumulator digunakan sebagai energi cadangan karena sumber energi tersebut tidak dapat mensuplai daya secara terus menerus. Oleh karena itu dibutuhkan alat pengisi akumulator dengan cara mengaliri arus listrik. Pengisian dihentikan ketika tegangan akumulator telah yang ditandai dengan tercapainya tegangan maksimum pada tegangan terminal akumulator. Apabila akumulator telah mencapai tegangan maksimumnya tetapi pengisian tetap dilakukan maka terjadi pemanasan yang akan memperpendek umurnya. Pada umumnya, alat pengisi akumulator menggunakan penyearah dengan center tap, akan tetapi tegangan keluaran yang dihasilkan tidak sesuai dengan tegangan pengisian akumulator. Pada penelitian ini, rangkaian push pull converter dengan kontrol umpan balik tegangan berbasis IC SG3525A diusulkan untuk ditelaah lebih lanjut. Selain itu, rangkaian konverter dilengkapi dengan relai pemutus otomatis untuk menghindari overcharge. Hasil pada penelitian ini, arus pengisian ketika akumulator dalam kondisi state of charge 10% yaitu sebesar 0,25 ampere. Dengan kondisi ini maka waktu yang dibutuhkan akumulator hingga penuh yaitu selama 41 jam. Pada pengujian dari kondisi tanpa beban ke kondisi berbeban, blok kontrol mengeluarkan respon berupa perubahan duty cycle dari setting awal 31,06 % ke 47,73 %, sehingga tegangan pengisian tetap lebih besar dari tegangan terminal akumulator. Kata kunci: Akumulator, konverter dorong tarik, relai, IC SG3525A  Abstract Accumulator is an alternative energy source and it is important for energy storage. The accumulator is often to be employed as reverse energy due to the electrical energy for accumulator can’t flow endlessly. There is a need for an accumulator charger, charging process must be stopped as the voltage on accumulator reach the maximum threshold. If an accumulator reaches its maximum voltage and it keeps being charged, the accumulator temperature will increase which can affect battery life. In general, accumulator charger uses transformer with center tapped rectifier, but its output voltage is not suitable for charge voltage. At this research, push pull converter circuit with voltage control feedback bases on IC SG3525A was proposed. An additional auto cut off relay to avoid overcharge was put into circuit. The experiment result show that the charging current at state of charge 10 % is 0,25 ampere. At this condition, accumulator needs 41 hours for fully charged. Testing carried out from no load to loaded showed that there is duty cycle change from 31,06 % to 47,73 %, and it causes charge voltage become bigger than accumulator voltage. Keyword : Accumulator, Push pull converter, relay, IC SG3525A
ANALISIS KINERJA INVERTER DENGAN RANGKAIAN RESONAN SERI DAN SERI-PARALEL BERBEBAN RECTIFIER- LED Prihanto, Tatas Ardhy; Facta, Mochammad; Riyadi, Munawar Agus
Transient: Jurnal Ilmiah Teknik Elektro TRANSIENT, VOL. 4, NO. 1, MARET 2015
Publisher : Universitas Diponegoro

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (530.162 KB) | DOI: 10.14710/transient.4.1.192-199

Abstract

Abstrak Resonansi pada rangkaian listrik merupakan keadaan dimana reaktansi induktif dan reaktansi kapasitif memiliki nilai yang sama . Reaktansi induktif akan meningkat seiring meningkatnya frekuensi sedangkan reaktansi kapasitif justru sebaliknya, akan menurun jika frekuensi meningkat. Jadi hanya akan ada satu nilai frekuensi dimana keadaan kedua reaktansi tersebut bernilai sama.Pada penelitian ini, dilakukan analisis tentang pengaruh beban ractifier-LED secara paralel terhadap rangkaian resonan, khususnya rangkaian resonan seri dan seri-paralel. Rangkaian resonan seri dan rangkaian resonan seri-paralel dapat mengubah gelombang tegangan yang dihasilkan oleh  inverter jembatan penuh.Hasil pengujian menunjukkan frekuensi resonansi rangkaian resonan seri hasil perancangan adalah 51,1kHz ,dan untuk rangkaian resonan seri-paralel adalah 18,5 kHz dan 65,1kHz. Dengan duty cycle sebesar 50%  dan tegangan masukan sebesar 14 Volt AC, rangkaian resonan seri mampu menghasilkan tegangan keluaran mencapai 154 Volt AC, dan untuk rangkaian resonan seri-paralel mampu menghasilkan tegangan 70 Volt AC dan 84 Volt AC. Beban rectifier-LED yang dicatu secara paralel tidak mengubah nilai frekuensi resonansi namun menurunkan nilai gain pada rangkaian. Kata kunci: Rangkaian resonan seri, Rangkaian resonan seri-paralel, Frekuensi resonansi, rectifier-LED  Abstract Resonance in an electric circuit is a condition when inductive reactance and capacitive reactance have equal value .  Inductive reactance will increase in line with increasing frequency while capacitive reactance would decrease if the frequency increased .So there is only one point of the frequency where the state of both the reactance is at the equal value.This research  analysed about the influence of the rectifier-LED load in parallel position with the resonant tank,the resonant tank was made in  a series and series-parallel circuit . The series and series-parallel  resonant circuit changed a wave of voltage that was produced by inverter full bridge.The experimental result showd that the resonance frequency of the series resonant circuit was 51,1khz and the resonance frequencies of the series-parallel resonant circuit were 18,5 khz and 65,1 khz. With duty cycle by 50 %, and the input voltage 14 volt, the series resonant circuit was able to produce an output voltage up to 154 volt and the series-parallel resonant was able to produce an output voltage up to 70 volt and 84 volt .The rectifier-LED load in parallel position  did not change the resonance frequency but it decreased the value of the gain. Keywords: Series resonant circuit, Series-parallel  resonant circuit, resonance frequency, rectifier- LED
ANALISIS TEGANGAN JATUH SISTEM DISTRIBUSI LISTRIK KABUPATEN PELALAWAN DENGAN MENGGUNAKAN ETAP 7.5.0 Putro, Andang Purnomo; Karnoto, Karnoto; Winardi, Bambang
Transient: Jurnal Ilmiah Teknik Elektro TRANSIENT, VOL. 4, NO. 1, MARET 2015
Publisher : Universitas Diponegoro

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (454.46 KB) | DOI: 10.14710/transient.4.1.122-127

Abstract

Abstrak Salah satu permasalahan dalam penyaluran daya listrik adalah besarnya tegangan jatuh di jaringan distribusi listrik. Hal ini biasanya dikarenakan oleh jarak pembangkit ke titik beban yang sangat jauh. Semakin besar tegangan jatuh yang terjadi pada sistem distribusi listrik maka kualitas energi listrik yang dikirimkan semakin buruk. Sistem distribusi listrik di Kabupaten Pelalawan, Provinsi Riau memiliki jaringan radial dengan jarak distribusi yang mencapai 200 kms. Berdasarkan simulasi ETAP 7.5.0 tegangan jatuh terbesar di jaringan tegangan menengah mencapai 41% dan di jaringan tegangan rendah 30%. Sebagai upaya untuk meminimalisir tegangan jatuh di sistem distribusi, pada analisis penelitian ini dilakukan rekonduktor dan pemasangan kapasitor bank. Dengan menggunakan ETAP 7.5.0 hasil tegangan jatuh dengan rekonduktor menjadi 40,05% sedangkan dengan kapasitor bank menjadi 35%. Setelah pemasangan kapasitor bank, tap transformator terendah dilakukan untuk mengatasi pengunaan AVR di jaringan tegangan rendah. Hasilnya untuk Kecamatan Pangkalan Kerinci, Pangkalan Kuras, dan bunut penggunaan AVR tegangan rendah dapat diatasi. Selain menggunakan perhitungan simulasi ETAP 7.5.0 dilakukan pula perhitungan manual yang hasilnya mendekati dengan hasil simulasi. Untuk jenis dimensi konduktor yang dipakai pada jaringan tegangan menengah sudah sesuai dengan kebutuhan. Kata kunci : Jatuh Tegangan, ETAP 7.5.0, Sistem Distribusi, Rekonduktor, Kapasitor Bank  Abstract Drop voltage is the one of problem in delectrical distribution system. It is usually caused by the long distance between electrical power station to the load. Quality of electrical power system become worse as the drop voltage in distribution increased.  Electrical distribution system in Pelalawan, Province of Riau has radial system with the longest distance reach 200 kms. Based on ETAP 7.5.0 simulation, drop voltage in electrical distribution of Pelalawan at midle voltage is 41% and at low voltage is 30%. Analysis of reconductor and instalation of capacitor bank were conclude in this research report to reduce drop voltage in Pelalawan’s electrical distribution system. The result of analysis based on ETAP 7.5.0 showed that the drop voltage in Pelalawan’s electrical distribution system decreaced to 35%. To revise the using of low voltage AVR, the lowest value of tap transformers is done after instalation of Capacitor Bank. The result show that the using of low voltage AVR in District of Pangkalan Kerinci, Pangkalan Kuras, and Bunut can be overcome. The Manual analytisis also showed the close value of drop voltage to the simulation of ETAP 7.5.0. Reconducting by selection dimention of conductor was carried out according to technical requirement. Keywords : Drop Voltage, ETAP 7.5.0, Distribution System, Reconductor, Capacitor Bank
PENGGUNAAN KONVERTER JENIS BUCK DENGAN PEMUTUS TEGANGAN OTOMATIS UNTUK PENGISI AKUMULATOR Setiawan, Eko; Facta, Mochammad; Nugroho, Agung
Transient: Jurnal Ilmiah Teknik Elektro TRANSIENT, VOL. 4, NO. 1, MARET 2015
Publisher : Universitas Diponegoro

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (576.574 KB) | DOI: 10.14710/transient.4.1.51-57

Abstract

Abstrak Pengisian muatan akumulator adalah dengan cara mengaliri akumulator dengan arus listrik secara terus menerus. Pengisian dihentikan ketika tegangan akumulator telah sampai pada tegangan maksimumnya. Ketika tegangan akumulator telah mencapai tegangan maksimumnya tetapi pengisian tetap dilakukan maka akan terjadi overcharge, sehingga hal ini dapat memperpendek umur akumulator. Dari beberapa topologi konverter arus searah, konverter jenis buck menarik untuk ditelaah lebih lanjut, karena konverter ini menghasilkan tegangan keluaran yang memiliki nilai maksimal sama dengan tegangan masukan. Pada penelitian ini dibahas mengenai perancangan menggunakan buck converter dengan pemutus tegangan otomatis untuk menghindari overcharge. Berdasarkan hasil percobaan, tegangan pengisian akumulator yang digunakan adalah sebesar 14,4 Volt dengan suhu ruangan kurang dari 30 derajat celcius. Pemutus tegangan otomatis berhasil menghentikan pengisian akumulator ketika terminal tegangan akumulator telah mencapai 13,8 Volt dan indikator berupa LED akan menyala. Efisiensi yang terukur pada rangkaian buck converter yaitu sebesar 84%. Kata kunci: buck converter ,akumulator, pemutus tegangan otomatis   Abstract Accumulator can be charged by flowing electric current through the accumulator continuously. Charging is stopped when the accumulator voltage has reached its maximum voltage. When it has reached its maximum voltage and the charging is on progress then there will be an overcharge. Futhermore,  it can shorten the accumulator lifetime. Based on direct current converter topologies, buck converter types are interested to be much more explored, because its voltage output has maximum value that equals to the input. In this final project, it is discussed about the design using buck converter with automatic voltage breakers to avoid overcharge. According to the experimental results, the accumulator voltage charging is around about  14.4 volts with the room temperature less than 30 celsius degrees. Automatic voltage breakers successfully stop the accumulator’s charge when the terminal voltage of the accumulator has reached 13.8 Volt followed by  LED indicator will be turn on as well. Efficiency measured in buck converter circuit  equals to 84%. Keywords: buck converter, accumulator, automatic voltage breakers
PERANCANGAN TROUBLE TICKET SYSTEM PADA UPT PUSKOM UNIVERSITAS DIPONEGORO Taftazan, Reza; Sudjadi, Sudjadi; Rochim, Adian Fatchur
Transient: Jurnal Ilmiah Teknik Elektro TRANSIENT, VOL. 4, NO. 1, MARET 2015
Publisher : Universitas Diponegoro

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (339.119 KB) | DOI: 10.14710/transient.4.1.215-218

Abstract

Abstrak Trouble Ticket System atau dikenal juga sebagai Issue Tracking System adalah suatu paket perangkat lunak computer yang mengatur dan menjaga daftar dari laporan – laporan permasalahan yang terjadi dalam suatu organisasi. Sistem Trouble Ticket biasanya digunakan pada Costumer Support atau Call Center atau Helpdesk dari suatu organisasi. Universitas Diponegoro sebagai salah satu Universitas Negeri yang perangkat teknologi informasinya telah tumbuh besar sudah seharusnya memiliki Sistem Trouble Ticket agar pemberutahuan terhadap terjadinya suatu masalah pada Sistem Informasi dapat dilaporkan dan diselesaikan dengan cepat serta terdokumentasikan. Sistem Trouble Ticket ini juga dapat dijadikan tolak ukur untuk pengambilan keputusan perlu tidaknya perbaikan atau bahkan penggantian sistem pada layanan Universitas Diponegoro. Sistem Trouble Ticket yang dirancang pada Tugas Akhir ini dibuat sebagai aplikasi web sehingga diperlukan web browser dan sambungan internet untuk mengaksesnya. Sistem ini dibuat menggunakan PHP dan Javascript untuk menjalankan fungsi – fungsinya serta HTML sebagai antarmuka tampilannya. Sistem Trouble Ticket ini juga menggunakan Gammu sebagai SMS Gateway, Protocol IMAP untuk pengambilan email, PHPMailer untuk mengirim email, dan MySQL untuk mengelola basisdata. Hasil pengujian  Sistem Trouble Ticket yang dirancang pada Tugas Akhir menunjukkan bahwa fungsi – fungsi pada sistem bekerja dengan baik. Permasalahan hanya akan terjadi jika pengguna tidak memasang atau mematikan Javascript pada web browser yang digunakannya. Kata kunci: sistem trouble ticket, tolak ukur, SMS Gateway, IMAP, PHPMailer.  Abstract Trouble Ticket System, also known as Issue Tracking System is a computer software package that manage and maintain a documents of issues that happen in an organization. Trouble Ticket System usually used in Costumer Support or Call Center or Helpdesk of an organization. Diponegoro University as one of Indonesian Nationals University that the informatics technology structure has grown big, to have Trouble Ticket System is a must. That is so the notification of some sort of problems that happen on the informatics system can be reported and solved faster and documented. This Trouble Ticket System also can be used as a benchmark to decided if the system service in Diponegoro University must be repaired or must be upgraded. Trouble Ticket System designed in this Final made as a web application that requires a web browser and an internet connection to access. This system is built using PHP and Javascript to run its functions, and HTML for the interface. This Trouble Ticket System also uses Gammu as SMS Gateway, IMAP protocol for email retrieval, PHPMailer to send emails, and MySQL to manage the database. The test result of this Trouble Ticket System designed on Final Project indicates that the functions work properly. The problem will only occur if the user does not install or turn off Javascript on the web browser. Keywords: engine torque control, fuzzy logic, spark ignition engine
PERANCANGAN PROTOTYPE SISTEM KONVEYOR PADA SISTEM PENGANGKUTAN MATERIAL KRAKATAU POSCO BERBASIS PLC Supriyo, Supriyo; Triwiyatno, Aris; Sumardi, Sumardi
Transient: Jurnal Ilmiah Teknik Elektro TRANSIENT, VOL. 4, NO. 1, MARET 2015
Publisher : Universitas Diponegoro

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (500.252 KB) | DOI: 10.14710/transient.4.1.155-160

Abstract

Abstrak Dalam dunia industri, teknologi memiliki peran yang penting dalam proses produksi. Salah satunya adalah perkembangan teknologi dalam bidang otomasi. Hal tersebut disebabkan meningkatnya permintaan konsumen terhadap barang-barang produksi dari suatu industri. Industri memerlukan suatu sistem yang dapat bekerja secara efisien dan dapat memonitoring hasil produksi. Salah satu industri yang menggunakan teknologi otomasi yaitu PT. Kratatau POSCO. Prototype ini menggunakan dua belas input dan  sebelas output yang digunakan. Input terdiri dari sensor, push button dan limit switch. Output teridiri dari motor DC, buzzer dan solenoid. Hasil dari pengujian ini  adalah pengambilan volume material memperoleh rata-rata 100,45cm3 dan error rata-rata 0,25. Pengangkutan material mempunyai rata-rata waktu 21,11 s dan rata-rata error 1,8 %. Volume dalam pengisian material mempunyai rata-rata 121,3 cm3  dan rata-rata eror 4,6%. Masa material dalam penampungan akhir mempunyai rata-rata 192,5 gram dan eror rata-rata 2,86 %.                                                       Kata kunci:  PLC, volume pengambilan, pengangkutan material, volume pengisian material dan massa material  Abstract In the industrial field , technology have very important role in production process. One of this technology is in automation field. That event caused increase request of consumer to goods production from an industry. Industry need an system that can work in efficient and can monitoring production result. One of industry that used the technology automation is PT. Krakatau POSCO. This Prototype used twelve input and eleven output. Input consists of censor, push button, and limit switch. Output consist of motor DC, buzzer, and solenoid. The test result of this project was the average of capturing material  100,45 cm 3 and the average rating of error 12%. Material transport  had an average time 21,11 s and the average error 1,8 %. Volume in the contents had an average 121,23 cm3 and the average error 4,6 %. Mass in the last shelter had an average 192,5 gram and average error 2,86%. Keywords: PLC ,volume of retrieval, the material transport , volume filling of material and mass of materials

Page 1 of 3 | Total Record : 30


Filter by Year

2015 2015


Filter By Issues
All Issue TRANSIENT, VOL. 13, NO.3, SEPTEMBER 2024 TRANSIENT, VOL. 13, NO.2, JUNI 2024 TRANSIENT, VOL. 13, NO.1, MARET 2024 TRANSIENT, VOL. 12, NO. 4, DESEMBER 2023 TRANSIENT, VOL. 12, NO. 3, SEPTEMBER 2023 TRANSIENT, VOL. 12, NO. 2, JUNI 2023 TRANSIENT, VOL. 12, NO.1, MARET 2023 TRANSIENT, VOL. 11, NO. 4, DESEMBER 2022 TRANSIENT, VOL. 11, NO. 3, SEPTEMBER 2022 TRANSIENT, VOL. 11, NO. 2, JUNI 2022 TRANSIENT, VOL. 11, NO. 1, MARET 2022 TRANSIENT, VOL. 10, NO. 3, SEPTEMBER 2021 TRANSIENT, VOL. 10, NO. 4, DESEMBER 2021 TRANSIENT, VOL. 10, NO. 2, JUNI 2021 TRANSIENT, VOL. 10, NO. 1, MARET 2021 TRANSIENT, VOL. 9, NO. 4, DESEMBER 2020 TRANSIENT, VOL. 9, NO. 3, SEPTEMBER 2020 TRANSIENT, VOL. 9, NO. 2, JUNI 2020 TRANSIENT, VOL. 9, NO. 1, MARET 2020 TRANSIENT, VOL. 8, NO. 4, DESEMBER 2019 TRANSIENT, VOL. 8, NO. 3, SEPTEMBER 2019 TRANSIENT, VOL. 8, NO. 2, JUNI 2019 TRANSIENT, VOL. 8, NO. 1, MARET 2019 TRANSIENT, VOL. 7, NO. 4, DESEMBER 2018 TRANSIENT, VOL. 7, NO. 3, SEPTEMBER 2018 TRANSIENT, VOL. 7, NO. 2, JUNI 2018 TRANSIENT, VOL. 7, NO. 1, MARET 2018 TRANSIENT, VOL. 6, NO. 4, DESEMBER 2017 TRANSIENT, VOL. 6, NO. 3, SEPTEMBER 2017 TRANSIENT, VOL. 6, NO. 2, JUNI 2017 TRANSIENT, VOL. 6, NO. 1, MARET 2017 TRANSIENT, VOL. 5, NO. 4, DESEMBER 2016 TRANSIENT, VOL. 5, NO. 3, SEPTEMBER 2016 TRANSIENT, VOL. 5, NO. 2, JUNI 2016 TRANSIENT, VOL. 5, NO. 1, MARET 2016 TRANSIENT, VOL. 4, NO. 4, DESEMBER 2015 TRANSIENT, VOL. 4, NO. 3, SEPTEMBER 2015 TRANSIENT, VOL. 4, NO. 2, JUNI 2015 TRANSIENT, VOL. 4, NO. 1, MARET 2015 TRANSIENT, VOL. 3, NO. 4, DESEMBER 2014 TRANSIENT, VOL. 3, NO. 3, SEPTEMBER 2014 TRANSIENT, VOL. 3, NO. 2, JUNI 2014 TRANSIENT, VOL. 3, NO. 1, MARET 2014 TRANSIENT, VOL. 2, NO. 4, DESEMBER 2013 TRANSIENT, VOL. 2, NO. 3, SEPTEMBER 2013 TRANSIENT, VOL. 2, NO. 2, JUNI 2013 TRANSIENT, VOL. 2, NO. 1, MARET 2013 TRANSIENT, VOL. 1, NO. 4, DESEMBER 2012 TRANSIENT, VOL. 1, NO. 3, SEPTEMBER 2012 More Issue