cover
Contact Name
Ir. Gigih Forda Nama, S.T., M.T.I., IPM.
Contact Email
gigih@eng.unila.ac.id
Phone
+6285289774152
Journal Mail Official
jitet@eng.unila.ac.id
Editorial Address
Jl. Prof. Soemantri Brojonegoro No. 1 Bandar Lampung 35145
Location
Kota bandar lampung,
Lampung
INDONESIA
Jurnal Informatika dan Teknik Elektro Terapan
Published by Universitas Lampung
ISSN : 23030577     EISSN : 28307062     DOI : DOI: 10.23960/jitet
Core Subject : Science,
Jurnal Informatika dan Teknik Elektro Terapan (JITET) merupakan jurnal nasional yang dikelola oleh Jurusan Teknik Elektro Fakultas Teknik (FT), Universitas Lampung (Unila), sejak tahun 2013. JITET memuat artikel hasil-hasil penelitian di bidang Informatika dan Teknik Elektro. JITET berkomitmen untuk menjadi jurnal nasional terbaik dengan mempublikasikan artikel berbahasa Indonesia yang berkualitas dan menjadi rujukan utama para peneliti.
Articles 11 Documents
Search results for , issue "Vol 1, No 1 (2013)" : 11 Documents clear
Pengaturan Tegangan PLTMH 5000 WATT Menggunakan Trafo Dengan Tap Yang Terkontrol Mikrokontroler ATmega 8535 Prasetio, Novan Giri
Jurnal Informatika dan Teknik Elektro Terapan (JITET) Vol 1, No 1 (2013)
Publisher : Universitas Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23960/jitet.v1i1.6

Abstract

AbstractTalang Java Village in Sukau district, West Lampung, is a villages that have no access to electricity of PT. PLN (Persero).  To meet the demand for electricity, people used the MHP(micro hydro power plants) as a source of electrical energy. MHP in talang Java village have several problems, which one is the distance of a potential energy source to residential areas which resulted distance the center of the load to generator It is cause voltage unstable system so that the voltage at the load side at low level. To overcome problem of unstable voltage, designed a tool in the form of a transformer which can regulate the voltage on the load side to a safe level. Moreover  the transformer equipped with a control circuit based AT Mega 8535 microcontroller. The use of a controller circuit aims to control voltage changes in MHP. From the test results, found that the load side voltage after mounted transformer, an increase. At first the voltage on the load side at the level of 150 volt, then  after the installation of transformers, voltage level is at 180 volt-220 volt.Keyword: Transformer, Voltage, Microcontroller

Page 2 of 2 | Total Record : 11